background image

 
 
4.2 INSTALLING THE RT16 

Screw the RT16 in position using suitable fixtures and fittings. 
There are holes in the back of the case which allow it to be secured to a single gang back box or 
round  surface  mount  box  should  you  require  an  additional  box  or  are  replacing  an  existing 
thermostat. 

 
 

1)  Wire the thermostat as per picture 

to the right and below making sure 
all  the  terminals  are  done  up 
tightly.  

2)  If  you  are  using  a  remote  sensor 

connect  to  terminals  5  and  6 
(marked  NTC)  of  the  thermostat 
using  any  insulated  copper  wire. 
Polarity  of  the  sensor  does  not 
matter.  

3)  Do NOT exceed total load of 16A. 

For loads greater than this, use a 
contactor  with  the  thermostat 
controlling the coil of the contactor. 

4)  Once  all  the  connections  have 

been  made,  make  sure  you 
reconnect  the  earth  cable  to  the 
front  cover  before  screwing  the 
cover to the back box. 

 
 

 

 
 

 

 

 

Содержание RT16

Страница 1: ...ng 7 Day 6 1 Day or 5 2 Day Default 5 2 Day Power Supply 230V ac 50 Hz 16A Maximum Load Battery back up Remote Sensor Optional NTC 10KΩ 0 5 C at 20 C Temperature Range 1 C to 45 C Default 5 C to 30 C Display LCD back light that comes on for short period when any button pressed Number of Programs Per Day 4 Tamper Resistant Facility for locking all buttons or just temperature adjustment buttons Dime...

Страница 2: ... that Monday is 1 Tuesday 2 etc If you don t press a button for 5 seconds display returns to standard mode and you will need to repeat section b Programming The controller is preset to the following times and temperatures Period Day Number Wake up Outdoor Back home Sleep 1 06 00 20 C 08 00 15 C 17 00 20 C 22 00 15 C 2 06 00 20 C 08 00 15 C 17 00 20 C 22 00 15 C 3 06 00 20 C 08 00 15 C 17 00 20 C 2...

Страница 3: ...the button 2 When ON press to toggle between Auto mode and Manual mode 3 When in Auto mode you can override the set tempreture by pressing the or buttons This override will last until the next program period and is shown by both the and symbols 4 When in Manual mode you can override the set tempreture by pressing the or buttons Note The thermostat will stay in Manual mode with the same set temprat...

Страница 4: ...l safety contact a qualified electrician Installation should always be carried out by a qualified electrician or a competent person in accordance with current electrical regulation Ensure that the cables are always protected against short circuit and overload The unit should be protected by a suitably rated isolator and fuse or MCB This controller is IP20 rated and is suitable for indoor or under ...

Страница 5: ...R REMOTE SENSORS The RT16 controller or sensors should be mounted on an internal wall approximately 1 5 meters from floor level and should be in a position away from draughts direct heat and sunlight If you decide to use remote sensors you will need to change A4 to N2 on the master default settings See page 7 for more information 5 Optional Air Sensor Part No CXS Optional Black Bulb Sensor Part No...

Страница 6: ...ure to the right and below making sure all the terminals are done up tightly 2 If you are using a remote sensor connect to terminals 5 and 6 marked NTC of the thermostat using any insulated copper wire Polarity of the sensor does not matter 3 Do NOT exceed total load of 16A For loads greater than this use a contactor with the thermostat controlling the coil of the contactor 4 Once all the connecti...

Страница 7: ...ature sensor N3 Do NOT use Select either N1 or N2 N3 See Note A below A5 lock settings 0 half lock 1 full lock 0 A6 Maximum set point of remote sensor 5 C 45 C 27 C A7 Minimum set point of remote sensor 1 C 10 C or Not active 5 C A8 Minimum set point of internal sensor 1 C 10 C 5 C A9 Maximum set point of internal sensor 20 C 45 C 30 C AA Power Cut function 0 Power heating as per controller memory...

Страница 8: ...T No liability is accepted for incorrect use of this product WARRANTY Your BN Thermic product is guaranteed for one year from date of purchase We will repair or replace at our discretion any part found to be defective We cannot assume any consequential liability This guarantee in no way prejudices your rights under common law and is offered as an addition to consumer liability rights RT16INS v01 T...