5 . 7     C O N EC T I N G     A N     R T 1 6   D I G I T A L   T H ER M O ST A T  

 

Use 1.0mm² 4 core cable 

 

Connections 

– (Colours for reference only) 

Connect Brown Live wire 

– Terminal 1 of Heater and Terminal L on the Thermostat (230V Live connection).  

Connect Grey Live wire 

– Terminal 2 of Heater and Terminal 1 on the Thermostat. Grey wire carries 230v.when thermostat is on. 

Connect Blue Neutral wire 

– Terminal N of Heater and Terminal N on the Thermostat (230V Neutral connection) 

Connect Green / Yellow wire 

– Terminal 

E or of Heater and Terminal E (Earth connection) on the Thermostat enclosure. 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE

 

 

PLEASE NOTE:-Turn up fully the internal thermostat on the back of the heater so it does not override this thermostat. 

 
 

6 .   C O N E C T I N G   H EA T ER S  I N   A   M A ST E R   SL A V E  A R A N G EM E N T  

 

IF  USING  THE  HEATERS  IN  A  MASTER  /  SLAVE  ARANGEMENT  PLEASE  READ  THE  FOLLOWING  IMPORTANT  NOTES 
BEFORE STARTING THE INSTALATION. 
 

All OUH2 heaters may be connected in a Master / Slave arrangement. 

The OUH2 heaters do not need to be the same Wattage or size. 

Some OUH2 can be connected using 400v 3 phase supply and some Single phase and still linked as Master / Slaves. 

If Using RCD (Residual Circuit Device) all Heaters connected in a Master / Slave arrangement MUST be supplied from the same 

RCD 

and not multiple RCD’s. Multiple MCB’s for each heater may and should be used as well. 

The controls are always added to the master heater and NEVER to any of the slave heaters. You may designate any OUH2 heater 

to be the master as long as you then follow the following. 

1)  Controls are only added to the master unit. 

2)  Controls if connected as shown in the wiring diagrams on pages 6 

– 8 are protected by the master heaters internal 3A 

fuse. 

3)  Link connections / cables (see section 7), if required are only added to the master unit. 

4)  You are full aware that if a slave unit is present in the system 400v ac may be present in the terminal  blocks even if all 

heaters are run on single phase due to supplies to each heater possibly being taken from different phases. 

5)  A maximum of 1 master and 15 slaves are used in each configuration. 

6)  Older OUH model heaters painted ivory in colour cannot be connected to these new OUH2 models. 

 

 

 

The  controls  and  heaters  may  be  fed  from  a  different 
source and it is essential that all circuit breakers feeding 
the heating system are isolated prior to any work being 
carried out on any of the heaters in the system.  

Links may be 
required 

– See 

Section 7 

Содержание OUH2 Series

Страница 1: ...or use only The controls and heaters may be fed from a different source and it is essential that all circuit breakers feeding the heating system are isolated prior to any work being carried out on any...

Страница 2: ...tside walls along the most exposed part of the building which is normally subjected to the prevailing winds see pictures at bottom of page MULTI FUNCTIONAL BRACKET Using the pictures above and to the...

Страница 3: ...ter in mounting position 7 8 or 9 you MUST remove the 2 side panels turn them around 180 and reinstall them Would you also please turn around the front guard so our Logo reads correctly Many Thanks 3...

Страница 4: ...een terminals L1 L2 L2 L3 can be found with this instruction leaflet Cable Sizes OUH2 03 3kW Use minimum 1 5mm 3 Core Mains Cable see note above OUH2 05 5kW Use 4mm 3 Core Mains Cable see note above O...

Страница 5: ...mote thermostats are used turn up the internal thermostat to full allowing the external thermostat to control the heater RST TP Tamperproof Thermostat Used exactly the same as the RST2 IN but temperat...

Страница 6: ...TAT Use 1 0mm 4 core cable Connections Colours for reference only Connect Black wire Terminal 10 of Heater and Terminal 3 on Frost Thermostat Connect Brown Live wire Terminal 11 of Heater and Terminal...

Страница 7: ...Earth connection on Control Switch HEATER to THERMOSTAT Connect Black wire Terminal 5 of Heater and Terminal 1 on Thermostat Please note Black wire can be joined in the control switch using a suitabl...

Страница 8: ...rminal 1 of Heater and Terminal L on Programmable Timer 230V Live connection Add a Link cable 1mm between Timer L connection and Timer Sin connection Connect Black wire Terminal 2 of Heater and Termin...

Страница 9: ...nd still linked as Master Slaves If Using RCD Residual Circuit Device all Heaters connected in a Master Slave arrangement MUST be supplied from the same RCD and not multiple RCD s Multiple MCB s for e...

Страница 10: ...nnect Black wire Terminal 6 of Master heater and Terminal 6 of first Slave heater Connect Grey wire Terminal 7 of Master heater and Terminal 7 of first Slave heater Connect Green Yellow wire Terminal...

Страница 11: ...g can damage the heater and is not covered by the guarantee 9 TROUBLE SHOOTING AND SOLUTIONS Wall thermostat does not work correctly in a Master Slave set up or single heater Check that you have turne...

Страница 12: ...t losses from the entire area you are heating If you are in any doubt please contact BN Thermic and we can carry out a quick check for you Temperature rise OUH2 industrial fan heaters warm a space by...

Отзывы: