1 0 .   M A I N T EN A N C E

 

Note:

 Before examining or carrying out any maintenance ensure the heater has cooled down and is disconnected from the mains 

supply. Due to the design of this heater there may be two different feeds ensure if so both are disconnected from the mains supply. 

The heaters are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require 

no service. Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign 

materials. This is especially important immediately before the heating season. Any dust build up can be loosened using a brush and 

a vacuum cleaner applied to the airways to ensure completed removal of any dust. When the heater is first turned on after cleaning 

an unusual odour may be noted this is due to the dust particles which inevitably will be disturbed and will be burnt off from the heating 

element.  

If in any doubt always consult a qualified electrician for advice. 

 

 

1 1 .   M A N U A L   R E S ET   C U T   O U T

 

The following should only be carried out by a qualified electrician. 

This heater is fitted with a manual resettable safety device to 

prevent overheating. The device  which is located inside the 

electrical control box will stop the contactor from working until 

it  is  reset.  The  contactor  turns  on  and  off  the  heating 

elements. Under normal conditions and operation this cut-out 

should never operate. Should the cut-out operate disconnect 

the heater from the mains supply making sure the heater is 

not fed from two different supplies. Wait for a minimum of 5 

minutes to allow the heater to cool down, check and remove 

any foreign materials around the airways. Now reset the cut-

out  by  pressing  the  black  knob  on  the  top.  If  the  problem 

persists, please contact us. 

 

 

 

 

12. I M PO R T A N T   N O T E S  R EG A R D I N G   S P A C E  H EA T I N G  

– PLEASE READ BEFO RE INSTALLING  

 

Total output 

It is vital that the combined output of the heaters exceeds the heat  losses from the entire area you are heating. If you are in any 

doubt, please contact BN Thermic and we can carry out a quick check for you. 

Temperature rise 

OUH2 industrial fan heaters warm a space by circulating large volumes of air. The temperature rise across the heater is often barely 

detectable. This is normal for this style of heater and does not indicate a fault. Our customer service advisers would be happy to talk 

through this characteristic of industrial fan heaters if clarification is needed. 

Now  you  have  read  and  accepted  the  above  points,  please  continue  with  your  installation  by  reading  through  the 

instructions first. Any questions you may have call our customer service advisors who will be delighted to help you. 

 

 
 
 
 

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 
notice. 

 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your BN Thermic product is guaranteed for a period of five years from date of purchase 

assuming  standard  comfort  heating  application.  Our  warranty  does  not  cover  corrosion  or  incorrect 
installation. We will repair or replace at our discretion any part found to be defective. We cannot assume 
any consequential liability. This guarantee in no way prejudices your rights under common law and is 
offered as an addition to consumer liability rights. 

REGISTER:

 Activate your warranty by registering online at www.bnthermic.co.uk and retain this 

installation data for future reference. 

 

 

 

 

 

 

 

 

              OUH2INS-v03-2

 

This product conforms to EU Directive 2002/96/EC. 
This appliance bears the symbol of the crossed waste bin. This indicates that, at the end of its useful life, it must not be disposed of as domestic 
waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user's responsibility to dispose of this 
appliance through the appropriate channels. Failure to do so may incur penalties established by laws governing waste disposal.

 

BN Thermic Ltd,  

34 Stephenson Way, Crawley, 

RH10 1TN 

Tel: 01293 547361 

Email: [email protected] 

Web: www.bnthermic.co.uk 

 

Содержание OUH2 Series

Страница 1: ...or use only The controls and heaters may be fed from a different source and it is essential that all circuit breakers feeding the heating system are isolated prior to any work being carried out on any...

Страница 2: ...tside walls along the most exposed part of the building which is normally subjected to the prevailing winds see pictures at bottom of page MULTI FUNCTIONAL BRACKET Using the pictures above and to the...

Страница 3: ...ter in mounting position 7 8 or 9 you MUST remove the 2 side panels turn them around 180 and reinstall them Would you also please turn around the front guard so our Logo reads correctly Many Thanks 3...

Страница 4: ...een terminals L1 L2 L2 L3 can be found with this instruction leaflet Cable Sizes OUH2 03 3kW Use minimum 1 5mm 3 Core Mains Cable see note above OUH2 05 5kW Use 4mm 3 Core Mains Cable see note above O...

Страница 5: ...mote thermostats are used turn up the internal thermostat to full allowing the external thermostat to control the heater RST TP Tamperproof Thermostat Used exactly the same as the RST2 IN but temperat...

Страница 6: ...TAT Use 1 0mm 4 core cable Connections Colours for reference only Connect Black wire Terminal 10 of Heater and Terminal 3 on Frost Thermostat Connect Brown Live wire Terminal 11 of Heater and Terminal...

Страница 7: ...Earth connection on Control Switch HEATER to THERMOSTAT Connect Black wire Terminal 5 of Heater and Terminal 1 on Thermostat Please note Black wire can be joined in the control switch using a suitabl...

Страница 8: ...rminal 1 of Heater and Terminal L on Programmable Timer 230V Live connection Add a Link cable 1mm between Timer L connection and Timer Sin connection Connect Black wire Terminal 2 of Heater and Termin...

Страница 9: ...nd still linked as Master Slaves If Using RCD Residual Circuit Device all Heaters connected in a Master Slave arrangement MUST be supplied from the same RCD and not multiple RCD s Multiple MCB s for e...

Страница 10: ...nnect Black wire Terminal 6 of Master heater and Terminal 6 of first Slave heater Connect Grey wire Terminal 7 of Master heater and Terminal 7 of first Slave heater Connect Green Yellow wire Terminal...

Страница 11: ...g can damage the heater and is not covered by the guarantee 9 TROUBLE SHOOTING AND SOLUTIONS Wall thermostat does not work correctly in a Master Slave set up or single heater Check that you have turne...

Страница 12: ...t losses from the entire area you are heating If you are in any doubt please contact BN Thermic and we can carry out a quick check for you Temperature rise OUH2 industrial fan heaters warm a space by...

Отзывы: