2 . I N T R O D U C T I O N & S P EC I F I C AT I O N
This air curtain produces a totally dry heat, no condensation, no gas, no fumes. It reaches maximum heat output within a minute
from being turned on. It is quick and easy to install reducing installation costs. Used with the CS-7 controller it can provide low / high
heat or fan only settings.
3 . L O C AT I O N O F AI R C U R T AI N
When mounting above a doorway, the air curtain can be wall or ceiling mounted at a recommended height of 2.5
– 3.5m above floor
level and a minimum of 300mm from adjacent walls.
4. M O U N T I N G I N ST AL L AT I O N
❑
IMPORTANT!
DO NOT mount air curtain directly below the power outlet.
❑
IMPORTANT!
Ensure that the mounting surface / ceiling supports are capable of taking the weight of the air curtain.
❑
IMPORTANT!
Do not allow any object to come closer than 1.5m to the air curtain outlet.
❑
IMPORTANT!
Always mount the air curtain horizontal mounting at any other angle will reduce the air curtain
’s life and
invalidate the guarantee.
❑
IMPORTANT!
The air intake and discharge areas must be kept completely clear for a minimum of 1.5m from the front of the
air curtain.
4.1 MOUNTING KIT
The mounting kit supplied with each air curtain consists of the following items.
1 x Backbone / spacer (approximately the same length as the air curtain).
2 x Backbone right angled brackets.
2 x Small wall mounting brackets, 2 x Large hanging brackets, 2 x Plastic domes
4 x M2.9 Self Tapping Screws, 6 x M5 x 12mm long pozi drive screws, 2 x M5 Lock washers 4 x M4 Nuts and 4 x M4
Washers.
4.2 WALL MOUNTING ABOVE A DOORWAY
Attach the two Small wall mounting brackets to the air curtain using the Plastic Domes and M2.9 Screws. Make sure both
open slots are facing downwards and the brackets face towards the back of the air curtain (see Pic 1).
Attach the 2 Backbone right angled brackets to the backbone using the M4 nuts and washers (see Pic 2)
Securely attach the Backbone to the wall using suitable fixings (not supplied) The back bone may be
removed once the two end brackets have been securely mounted in position. It is only required to obtain
the correct spacing of the Backbone right angled brackets. Partially insert M5 screws into the outer two
holes in each end of the bracket. Make sure the screw goes all the way through and the thread is just
showing the other side (see Pic 2). The air curtain with its two end brackets should now be slotted onto the
fixing bracket (see Pic 3). Now tighten up the four end screws and add an additional M5 centre screw and
lock washer into the centre hole at each end of the fixing bracket (see Pic 4). UNDER NO
CIRCUMSTANCES MUST THE AIR CURTAIN BE TURNED ON IF THESE TWO CENTRE SCREWS
AND LOCK WASHERS ARE NOT PRESENT OR TIGHTENED UP.
Model
CAT-90
Power
9000W
Input supply
230v or 400v 3 Phase
Dimensions (W x D x H)
1620 x 108 x 225mm
Weight
19kg
Recommended Mounting Height
2.5 - 3.5M
Safety Distance from Air curtain
1.5M
Optional Controller Model Number
CS-7
Optional Tamperproof Thermostat
RST-TP
CS-7
Controller
(Optional Extra)
RST-TP
Tamperproof Thermostat
(Optional Extra)
Pic 2
Pic 3
Pic 4
M5 Lock Washer
M4 Nuts & Washers
Pic 1