Thank you for purchasing a BN Thermic product. Manufactured to a high standard, this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
Please ensure instructions remain with your customer for their reference.
1. S AF ET Y I N ST R U C T I O N S
1.1 ELECTRICAL SAFETY
WARNING!
It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any
other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety
devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. If in any doubt consult a qualified
electrician.
You must also read and understand the following instructions concerning electrical safety.
▪
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
▪
Installation should always be carried out by a qualified electrician or a competent person in accordance with current electrical regulation.
▪
Ensure that the insulation of all the cables on the appliance is undamaged and safe, before connecting it to the power supply.
▪
Ensure that the cables are always protected against short circuit and overload.
▪
Regularly inspect the power supply cables and plugs etc. for wear or damage and check all connections to ensure that none are loose.
▪
Important: Ensure that the voltage marked on the appliance matches the power supply to be used and that a correctly rated fuse is fitted.
▪
DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item repaired or replaced by a qualified electrician.
▪
The unit should be protected by a suitably rated isolator and fuse or MCB.
▪
This air curtain is IP20 rated and is suitable for indoor or under cover use only.
▪
Do not attach this air curtain to an extension cord it must be hard wired in position.
1.2 GENERAL SAFETY INSTRUCTIONS
✓
Remove all packaging and store it away from children, check the package and air curtain for visible damage or tampering.
✓
Familiarise yourself with the applications and limitations of the air curtain.
✓
Ensure the air curtain is in good order and condition both physically and electrically before use. If in any doubt, do not use the unit and
contact your supplier.
✓
Only use recommended attachments and parts. To use unauthorised parts may be dangerous and will invalidate your warranty.
✓
Keep tools and other items away from the air curtain when it is in use.
✓
Keep children and unauthorised persons away from the air curtain, as it gets
hot.
✓
Disconnect from mains and allow to cool before attempting any cleaning or maintenance.
X
DO NOT
use in areas where hazardous gasses or dusts that may be present.
X
DO NOT
locate the air curtain directly below the power outlet.
X
DO NOT
disassemble the air curtain for any reason.
This air curtain must be checked by qualified
personnel only.
X
DO NOT
use this air curtain to perform a task for
which it has not been designed.
❑
WARNING!
This air curtain is not equipped with a
built in device to control the room temperature. Do
not use this air curtain in a small room if it is
occupied by people not capable of leaving the room
on their own, unless constant supervision is
provided.
❑
WARNING!
Ensure you observe the safety distances
and mounting heights and there is no possibility of
inflammable materials coming into contact.
2. I N T R O D U C T I O N & S P EC I F I C AT I O N
This air curtain produces a totally dry heat, no condensation, no gas, no fumes. It reaches maximum heat output within a minute from being turned
on. It is quick and easy to install reducing installation costs. Used with the CS-7 controller it can provide low / high heat or fan only settings.
Model
CAD-60
Power
6000W
Input supply
220-240V
Dimensions (W x D x H)
1105 x 108 x 225mm
Weight
13.5kg
Recommended Mounting Height
2.5 - 3.5M
Safety Distance from Air curtain
1.5M
Optional Controller Model Number
CS-7
Optional Tamperproof Thermostat
RST-TP
PLEASE READ THESE INSTRUCTIONS, NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS,
AND CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
CS-7
Controller
(Optional Extra)
RST-TP
Tamperproof Thermostat
(Optional Extra)
INSTRUCTIONS FOR:-
COMMERCIAL AIR CURTAIN
Model:- CAD-60
REGISTER
: PLEASE REGISTER THIS PRODUCT ONLINE TO ACTIVATE YOUR GUARANTEE AT
www.
bnthermic
.co.uk