5.4
230V SINGLE PHASE
– With CS-7 Controller and RST-TP Thermostat. When on
fan runs continuously and heat turns on / off
with thermostat.
Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.
Drawings show connections inside the small and large black terminal box on the outside of the air curtain and the inside of the CS-7 and RST-TP
Thermostat Controllers. Other thermostats may be used BUT they must be suitable for a 10A load.
Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes.
Standard Connection using CS-7 Controller and Thermostat
-
Do NOT use power tools to undo or do up terminal screws.
Use 4mm² 3 Core Mains Cable (see note above).
Use 1.5mm² 6 Core Cable to connect the air curtain to the CS-7 Controller (see note above).
Use 1.5mm² 4 Core Cable to connect the CS-7 Controller to Thermostat (see note above).
Remove any links
that may be present in air curtain terminal box between terminals 1,2,3,4 or 5.
Mains Cable
Connect Brown wire
– Terminal 1 or L.
Connect Blue wire
– Terminal 5 or N.
Connect Green / Yellow wire
– Terminal E or
Air curtain to CS-7 Controller Cable
– (Colours for reference only)
Remove the Dark Brown link cable from the centre switch terminal 1 to the right centre switch terminal L1.
Connect Brown wire
– Terminal 1 or L of air curtain and Top Terminal L2 on the right DP Switch of CS-7.
Connect Grey wire
– Terminal 2 of air curtain and L1 on right DP Switch of CS-7.
Connect Red wire
– Terminal 3 of air curtain and Terminal 1 on Left SP Switch of CS-7.
Connect Black wire
– Terminal 4 of air curtain and Terminal 2 on Left SP Switch of CS-7.
Connect Blue wire
– Terminal 5 or N of air curtain and Top Terminal N2 on right DP Switch of CS-7.
Connect Green / Yellow wire
– Terminal E or
of air curtain and earth connection on CS-7.
CS-7 Controller to Thermostat Cable
– (Colours for reference only)
Connect Brown wire
– Bottom Terminal L1 on right DP Switch of CS-7 and Terminal 3 of the Thermostat.
Connect Purple wire
–Terminal 1 of middle Switch of CS-7 and Terminal 1 of the Thermostat.
Connect Blue wire
– Bottom Terminal N1 on right DP Switch on CS-7 and Terminal 4 or N of the Thermostat.
Connect Green / Yellow wire
– Terminal E or
of CS-7 and earth connection of the Thermostat.
PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE
5. M AI N T E N AN C E
Note:
Before examining or carrying out any maintenance ensure the air curtain has cooled down and is disconnected from the mains supply.
The air curtains are intended to operate for many years, problem free. All moving parts are factory lubricated and therefore should require no
service. Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is
especially important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the
airways to ensure completed removal of any dust. When the air curtain is first turned on after cleaning an unusual odour may be noted this is due to
the dust particles which inevitably will be disturbed and will be burnt off from the heating element.
If in any doubt always consult a qualified electrician for advice.
6. AU T O C U T O U T / F U S E R E PL AC EM E N T
This air curtain is fitted with a semi-automatic safety device to prevent overheating. The device will isolate the heating element while the fan
continues to operate. Should this occur, disconnect the air curtain from the mains supply for a minimum of 5 minutes, check and remove any foreign
materials around the airways. If the air curtain fails to operate or the safety cut out operates again, turn off the air curtain and contact a qualified
electrician.
The Heater is protected by a fuse. The fuse holder is located on the front face of the unit. Should the fuse fail, replace with another 12.5A fuse. If
this replacement fuse fails seek professional help.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Your BN Thermic product is guaranteed for one year from date of purchase. We will
repair or replace at our discretion any part found to be defective. We cannot assume any consequential
liability. This guarantee in no way prejudices your rights under common law and is offered as an
addition to consumer liability rights.
REGISTER:
Activate your warranty by registering online at www.bnthermic.co.uk and retain this
installation data for future reference.
CAD-60INS-v01-1