5.4 

230V SINGLE  PHASE 

– With CS-7 Controller and RST-TP Thermostat. When on 

fan runs continuously and heat turns on / off 

with thermostat.

 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  
Drawings show connections inside the small and large black terminal box on the outside of the  air curtain and the inside of the CS-7 and RST-TP 
Thermostat Controllers. Other thermostats may be used BUT they must be suitable for a 10A load.  

Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes.

 

 
 

Standard Connection using CS-7 Controller and Thermostat

 

-

 Do NOT use power tools to undo or do up terminal screws.

 

Use 4mm² 3 Core Mains Cable (see note above). 
Use 1.5mm² 6 Core Cable to connect the air curtain to the CS-7 Controller (see note above). 
Use 1.5mm² 4 Core Cable to connect the CS-7 Controller to Thermostat (see note above). 
Remove any links 

that may be present in air curtain terminal box between terminals 1,2,3,4 or 5. 

Mains Cable 

Connect Brown wire 

– Terminal 1 or L. 

Connect Blue wire 

– Terminal 5 or N. 

Connect Green / Yellow wire 

– Terminal E or  

 

Air curtain to CS-7 Controller Cable 

– (Colours for reference only) 

Remove the Dark Brown link cable from the centre switch terminal 1 to the right centre switch terminal L1. 

Connect Brown wire 

– Terminal 1 or L of air curtain and Top Terminal L2 on the right DP Switch of CS-7. 

Connect Grey wire 

– Terminal 2 of air curtain and L1 on right DP Switch of CS-7. 

Connect Red wire 

– Terminal 3 of air curtain and Terminal 1 on Left SP Switch of CS-7. 

Connect Black wire 

– Terminal 4 of air curtain and Terminal 2 on Left SP Switch of CS-7. 

Connect Blue wire 

– Terminal 5 or N of air curtain and Top Terminal N2 on right DP Switch of CS-7. 

Connect Green / Yellow wire 

– Terminal E or 

of air curtain and earth connection on CS-7. 

 

CS-7 Controller to Thermostat Cable 

– (Colours for reference only) 

Connect Brown wire 

– Bottom Terminal L1 on right DP Switch of CS-7 and Terminal 3 of the Thermostat. 

Connect Purple wire 

–Terminal 1 of middle Switch of CS-7 and Terminal 1 of the Thermostat. 

Connect Blue wire 

– Bottom Terminal N1 on right DP Switch on CS-7 and Terminal 4 or N of the Thermostat. 

Connect Green / Yellow wire 

– Terminal E or 

of CS-7 and earth connection of the Thermostat. 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE 

5. M AI N T E N AN C E

 

Note:

 Before examining or carrying out any maintenance ensure the air curtain has cooled down and is disconnected from the mains supply. 

The  air  curtains  are  intended  to  operate  for  many  years,  problem  free.  All  moving  parts  are  factory  lubricated  and  therefore  should  require  no 
service. Maintenance is limited to keeping both the inlet and outlet areas free from any accumulation of dust or any other foreign materials. This is 
especially important immediately before the heating season. Any dust build up can be loosened using a brush and a vacuum cleaner applied to the 
airways to ensure completed removal of any dust. When the air curtain is first turned on after cleaning an unusual odour may be noted this is due to 
the dust particles which inevitably will be disturbed and will be burnt off from the heating element. 
If in any doubt always consult a qualified electrician for advice. 

 

6. AU T O   C U T   O U T   /   F U S E   R E PL AC EM E N T  

This  air  curtain  is  fitted  with  a  semi-automatic  safety  device  to  prevent  overheating.    The  device  will  isolate  the  heating  element  while  the  fan 
continues to operate. Should this occur, disconnect the air curtain from the mains supply for a minimum of 5 minutes, check and remove any foreign 
materials around the airways. If the  air curtain fails to operate or the safety cut out operates again, turn off the  air curtain and contact a qualified 
electrician.  
The Heater is protected by a fuse. The fuse holder is located on the front face of the unit. Should the fuse fail, replace with another 12.5A fuse. If 
this replacement fuse fails seek professional help.   

 

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without 
prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this product.

 

WARRANTY: 

Your  BN  Thermic  product  is  guaranteed  for  one  year  from  date  of  purchase.  We  will 

repair or replace at our discretion any part found to be defective. We cannot assume any consequential 
liability.  This  guarantee  in  no  way  prejudices  your  rights  under  common  law  and  is  offered  as  an 
addition to consumer liability rights. 

REGISTER:

  Activate  your  warranty  by  registering  online  at  www.bnthermic.co.uk  and  retain  this 

installation data for future reference. 

 

 

 

 

 

 

 

 

                  CAD-60INS-v01-1 

Отзывы: