background image

 
 
 
Functions 

1.  This charger is suitable to charge a

 

13,2 Volt Li-Fe battery pack,   

4

 

cells in serial. The max. charge current is 3.0A. 

 

2.  The charger has an overload, short circuit and overvoltage   

protection. 
Overload protection (cut off if the output current is higher than 
3.5A) 
Short circuit (cut off if there is a short circuit on the DC-side) 
Overvoltage protection (cut off if the output voltage is higher than 
20V) 
 

Operation 

1.  Before first use please check the parameters of the charger and 

your battery according the rating label or the manual to ensure the 
accordance

.

 

2.  Check if that the local main AC voltage level is suitable for the 

charger. 
 

 

Minimal 

Maximal 

AC input voltage 

100 

240 

 

3.  For a function test plug in the mains cable of the charger into an 

AC mains socket. The LED (green) will indicate stand by. 

4.  Connect the DC cable with the right polarity (red clamp +, black 

clamp -) to the battery pack. The red LED turns on and shows the 
charger is connected to the mains voltage and charging is started. 

5.  If the battery pack is fully charged the LED turns from red to green   

and indicates the full battery pack

.

 

6.  Short circuit, overload and overvoltage will be indicated by 

flashing of the LED red and green alternatively. 

 
 
 
 
 
 
 
 

 
 
 
 

Status 

Indicators Duo LED red/green 

Stand by 

green on 

Charge 

red on 

Battery full 

green on 

 
Charge end voltage 14,4 V +/-1%

 

 

 
Remarks 

The right polarity is the base that the charger generates a charge 
voltage.   

 

Content 

1.  Charger with dc cable 
2.  Operating instructions 

 
 
 
 
 
 
 
 
 

 

Содержание 20928

Страница 1: ...UNGSANLEITUNG OPERATING INSTRUCTION LADEGERÄT CHARGER 14 4Vdc 3 0A Artikel Nr Part No 20928 Geeignet zum Laden eines 4 Zellen in Serie 13 2 Li Fe Akkupack Suitable to charge a 4 cells in serial 13 2V Li Fe Battery pack Bedienungsanleitung vor Gebrauch sorgfältig lesen Read this operating instruction carefully before use ...

Страница 2: ...men Gerät nicht öffnen oder Änderungen vornehmen Reparaturen dürfen nur von autorisiertem Fachpersonal mit original Ersatzteilen durchgeführt werden General Safety Instructions Read these operating instructions carefully before use Improper handling of Lithium Batteries may cause fire explosion or chemical danger Check battery manufacturer instructions Charge only Li Fe battery packs Do not charge...

Страница 3: ...gnet ist Minimal Maximal Eingangsspannung Volt 100 240 3 Zur Funktionsüberprüfung stecken den Netzstecker des Ladegerätes in die Steckdose Die grüne LED leuchtet bei Bereitschaft 4 Verbinden Sie das Ladekabel polrichtig rote Klemme schwarze Klemme mit Ihrem Akku Die rote LED signalisiert dass das Ladegerät mit der Netzspannung verbunden ist und der Ladevorgang gestartet wurde 5 Ist der Akku voll a...

Страница 4: ...rger Minimal Maximal AC input voltage 100 240 3 For a function test plug in the mains cable of the charger into an AC mains socket The LED green will indicate stand by 4 Connect the DC cable with the right polarity red clamp black clamp to the battery pack The red LED turns on and shows the charger is connected to the mains voltage and charging is started 5 If the battery pack is fully charged the...

Отзывы: