SFU-0303
M a n u a l
E
- 39 -
Error Description
Cause
Fixing
Loose connection in spindle, spindle
cable or at the connectors
> Check spindle cable and exchange
potentially
> Check connectors
With activated speed
sensor:
The spindle runs properly,
but sometimes there
appears the message
Encoder Error
.
Disturbances on the signal or the
signal amplitude is too low
> sensor wires in spindle cable are
not shielded
> Exchange spindle cable
> for verification test exchange spindle
Spindle cable is defective
> Check the 3 spindle phase wires
Error
Without Spindle,
Cable
is displayed
Spindle cable too long
With activated spindle test, a test
current is send via spindle cable to the
spindle by applying a voltage at output
lines. In case that this current is too
low, or a wrong spindle characteristic
selected, it does not match to the
reference values and the spindle test
fails.
> Check, if the proper characteristic is
selected.
> Increase value for start voltage in the
spindle characteristic
-> contact BMR
> Deactivate function "Spindle test"
Содержание SFU-0303 Series
Страница 1: ...Frequency Converter SFU 0303 SSE Version Desktop Version 19 Version ...
Страница 6: ...SFU 0303 M a n u a l E 6 3 Block diagram picture 1 ...
Страница 43: ...SFU 0303 M a n u a l E 43 17 Mechanic Views and Dimension 17 1 SSE Version for cabinet mounting ...
Страница 44: ...SFU 0303 M a n u a l E 44 17 2 19 Version ...
Страница 45: ...SFU 0303 M a n u a l E 45 17 3 Version Desktop ...
Страница 46: ...SFU 0303 M a n u a l E 46 this page is left intentionally left blank ...
Страница 47: ...SFU 0303 M a n u a l E 47 this page is left intentionally left blank ...