SFU-0303
M a n u a l
E
- 32 -
Example 1, normal adjustment:
A 2-pole motor with a maximum rotational speed of 30.000rpm needs at this point a nominal voltage of
220V at a current of 5A .
Picture 21
Example 2, weakened field, field suppression:
A 2-pole motor with a maximum rotational speed of 30.000rpm needs at 20.000rpm a nominal voltage
of 220V at a current of 5A . But the voltage cannot be raised further, so the desired speed can be
achieved but with reduced power.
Picture 22
The current limit, in this case 8A, indicates the S6 mode, where it is 5A as the nominal current for the
S1 mode.
The acceleration values (Ramp up/down) should be setup to be 12000rpm/sec. It has to be ensured
that the shaft can rotate freely.
Start the automatic and save the characteristic after having finished the procedure. Download it into
the converter.
Caution:
If using this autotuning, damages at spindles or the converter are part of warranty,
due to possible wrong input values.