ABOUT THE BC300 EXTERNAL SHUNT AND COMMLINK

The BMPRO BC300 External Shunt and CommLink devices provide wireless 

battery monitoring for high current BatteryPlus35 and J35 systems.
The addition of the BC300 External Shunt and CommLink to BP35 and 

J35 systems allows high current loads to be directly connected to the 

battery via the BC300 External Shunt. This enhances the system behavior 

with temperature monitoring of the battery for greater protection. It also 

maintains Time Remaining and State of Charge determination of the battery 

even at high currents and with directly connected loads.
The BC300 External Shunt is designed for 12V batteries up to 800Ah in 

capacity. The shunt is rated for ±240A of continuous current and transmits 

monitored data wirelessly.
The BC300 External Shunt monitors the following battery properties:

  

9

Voltage

  

9

Charging/discharging current

  

9

Energy usage (Ah)

  

9

Temperature

Note:

 when installing the BC300 External Shunt a direct connection to the 

battery is required.
The CommLink provides wireless reception of the battery data transmitted 

by the BC300 External Shunt. Data received by the CommLink is forwarded 

to the CAN communication bus for reception by a BatteryPlus35 or J35. The 

CAN communication bus also provides operating power for the CommLink.
The CAN communication bus can also be used to connect to a BMPRO 

Battery Monitor, such as the BMPRO Odyssey or Trek3.

Содержание BC300 XTERNAL SHUNT

Страница 1: ...OWNER S MANUAL BC300 CommLink EXTERNAL SHUNT TEAMBMPRO COM ...

Страница 2: ......

Страница 3: ...Inspired by the great outdoors we have created a range of rugged smart and reliable products to power your adventures Our range of battery power and RV management and control systems gives you peace of mind when you are on the road so that you can relax in even the most far flung destinations knowing you have control over your power needs To learn more about the BMPRO range of products please visi...

Страница 4: ...ove any personal metal adornment such as chain watch or ring before handling the battery Batteries are electrically live at all times and must be treated with extreme caution They can supply high short circuit currents even if they appear damaged or undamaged Do not drop or shake the product vigorously as this may cause damage to the product Do not shock the equipment batteries and charger as this...

Страница 5: ...htly with a dry or moist cotton cloth if required Do not use alcohol thinners benzene or any other chemical cleaner This device is a high precision electronic product It contains no user serviceable parts inside Do not try to dismantle modify or repair it yourself Disassembly by unauthorised persons will void the warranty Product specifications are subject to change and improve without notice ...

Страница 6: ...which may occur from the improper or unsafe use of its products Warranty is only valid if the unit has not been modified or misused by the customer MANUAL PART 036326 REV 4 0 Contents SAFETY PRECAUTIONS 4 ABOUT THE BC300 EXTERNAL SHUNT AND COMMLINK 8 DESCRIPTION OF PARTS 9 BC300 EXTERNAL SHUNT 9 COMMLINK 10 MOUNTING 10 INSTALLATION 11 INDICATORS 14 BC300 EXTERNAL SHUNT BATTERY INDICATORS 14 COMMLI...

Страница 7: ...7 ...

Страница 8: ...0 External Shunt is designed for 12V batteries up to 800Ah in capacity The shunt is rated for 240A of continuous current and transmits monitored data wirelessly The BC300 External Shunt monitors the following battery properties 9 Voltage 9 Charging discharging current 9 Energy usage Ah 9 Temperature Note when installing the BC300 External Shunt a direct connection to the battery is required The Co...

Страница 9: ...RY CONNECTION 2 NEW NEGATIVE TERMINAL CONNECTION Connects to the load Note This terminal has flat sides 3 POSITIVE FLYING LEAD AND TEMPERATURE SENSOR 4 LED STATUS INDICATOR 2 3 1 4 DESCRIPTIONOFPARTS BC300 EXTERNAL SHUNT ...

Страница 10: ...h as the BatteryPlus35 or J35 or BMPRO Battery Monitors such as the BMPRO Odyssey or Trek3 6 RECESSED STATUS INDICATOR 7 RECESSED PAIR BUTTON COMMLINK Trek BatteryPlus35 II OdysseyLink ControlNode RVView J35 Battery Monitors Battery Management Systems Nodes All negatives CAN Cable ...

Страница 11: ...g lead provides a connection to the positive terminal of the battery to power the BC300 External Shunt This lead is also used to measure the battery temperature and voltage and must be directly connected to the positive terminal of the battery Please ensure that all loads connected to the battery are disconnected or turned off before beginning the installation procedure below to avoid sparks being...

Страница 12: ...unt battery positive is connected 5 Connect all positive load connections including the BC300 External Shunt s positive flying lead 3 to the battery positive terminal Once these connections are made the BatteryPlus35 CommLink and BC300 External Shunt are all powered The BC300 External Shunt s battery indicator will flash blue for 2 minutes after power up 6 Now check the CommLink status indicator 6...

Страница 13: ...n flashing green at 5 second intervals Continue to step 8 b If pairing fails the CommLink status indicator 6 will return to flashing orange If this happens then disconnect the BC300 External Shunt s positive flying lead 3 from the battery and return to step 5 to repeat the pairing procedure Note if you have multiple pairing failures at this step try installing the CommLink closer to the BC300 Exte...

Страница 14: ...able for pairing Normal operation One or more battery fault conditions detected Battery voltage outside 8V 16C range Battery current exceeding 300A Battery temperature outside 20 C to 70 C range BC300 External Shunt temperature outside operating limits INDICATORS BC300 EXTERNAL SHUNT BATTERY INDICATORS COMMLINK STATUS INDICATORS ...

Страница 15: ......

Страница 16: ...ity Non operating 95 RH non condensing Dimensions Approx 140 x 65 x 18 6mm 92 x 52 x 25mm Weight Approx 1kg 150g IP Rating IP 54 IP 30 BATTERY MONITORING SPECIFICATIONS Voltage Range 8V to 16V Voltage Resolution 20mV Current Resolution 200mA Current Range 240A continuous Overload Protection 100ms without damage 800A Temperature Range Battery Terminal 20 to 70 C Temperature Resolution 3 C Capacity ...

Страница 17: ......

Страница 18: ... claim under this warranty HOW TO PROTECT YOUR RIGHTS UNDER THIS WARRANTY 3 This warranty does not extend to product failures or defects caused by or associated with but not limited to failure to install or maintain correctly unsuitable physical or operating environment accident acts of God hazard misuse unauthorised repair modification or alteration natural disaster corrosive environment insect o...