INSTALLATION
Please note that if your device requires pairing at Step 7, a pen or similar will
be required for operation of the recessed button.
1.
Please practice standard safety precautions and remove all connections
to the battery
2.
Connect the CommLink to the BatteryPlus35 or J35 CAN bus with the
provided CommLink data cable. The data cable can be plugged into
either CAN bus socket on the CommLink
5
3.
Connect
1
to the battery negative terminal using the connector provided
or directly to the battery. It is important that the correct terminal on both
the battery and the BC300 External Shunt is used.
4.
Connect all negative load connections to
2
on the BC300 External Shunt.
Note:
Steps 5, 6 and 7 must be completed before the BC300 External Shunt’s
battery indicator stops flashing
blue
- 2 minutes from the time the BC300
External Shunt battery positive is connected.
5.
Connect all positive load connections including the BC300 External
Shunt’s positive flying lead
3
to the battery positive terminal. Once these
connections are made the BatteryPlus35, CommLink and BC300 External
Shunt are all powered. The BC300 External Shunt’s battery indicator will
flash
blue
for 2 minutes after power up.
6.
Now check the CommLink status indicator
6
a. If the CommLink status indicator is now flashing
green
at 5 second
intervals the CommLink is already paired and is receiving data from
the BC300 External Shunt. Go to step 8.
b. If the CommLink status indicator is flashing
orange
this indicates it
requires pairing to the BC300 External Shunt. Continue to step 7.
c. If the CommLink status indicator is flashing
red
it is paired to a
BC300 External Shunt, but not receiving data. Clear the pairing by
pressing the CommLink pair button
7
with a pen or similar until the
CommLink status indicator changes from flashing
red
to flashing
orange
. This should occur after 5 seconds. Continue to step 7.