12
SWAYCONTROL SELF DIAGNOSTICS
The SwayControl performs a self-diagnostic test every time it “wakes-up” upon
receiving a signal from the brake controller in the tow vehicle. The Status Light
may flash
RED
and
GREEN
approximately six times on start-up then go
GREEN
.
Once in operation, the SwayControl continually monitors the system for faults.
If the system is operating properly and no fault is detected, the
GREEN
light will
remain on and flicker or pulse.
If the SwayControl detects a fault in the system, the Status Light will turn
RED
and the fault may be diagnosed from the
RED
Status Light flash sequence. The
SwayControl continues checking the fault status and the
RED
Status Light will
continue to flash until the fault is corrected. Once the fault has been corrected,
the
GREEN
light returns.
For more information, refer to
Troubleshooting with the Status Light.
WARNING
When the caravan/trailer is not moving, every 60 seconds the
GREEN
light will turn
off for two seconds, then turn back on. This is normal and indicates normal operation
of the SwayControl.
If you notice the
GREEN
light turning off and on every 60 seconds and the caravan/
trailer is moving, have your SwayControl checked by your local service centre.
STATUS LIGHT MODULE INSTALLATION
Once wiring is completed, route the Status Light cable to the front of the
caravan/trailer. Then mount the Status Light module onto a flat surface on the
drawbar of the caravan/trailer using self-tapping screws.
Select a location that makes it easy to see the Status Light when looking at the
front of the caravan/trailer.