Synchronization
In NextView
®,
AMS42-LAN16fx devices can do measurement time-synchronously in relation to real-
time. The frequency of the sample clock is adjusted by means of a configured NTP server. Settings
for time-synchronous measurements are done in the AMS42-LAN16f Administration Utility (see chap-
ter 1.1) as well as in NextView and are described in the user manual
UM-LAN-ADMIN
.
6
Supplementary Products for the AMS42-LAN16fx
6.1
5B Modules (MA Line)
The 5B measuring amplifiers from bmcm allow for the professional sig-
nal adjustment to a data acquisition system.
The amplifier output is
±
5V or 0..5V. Most of the modules are electri-
cally isolating and provide sensor supply.
The following 5B modules from bmcm are available:
Product
Description
MA-UNI
universal amplifier with galvanic isolation for U, I, R, thermocouple, strain gauge, LVDT
MA-UI
multi-range amplifier with galvanic isolation for U, I
MA-U
voltage measuring amplifier with galvanic isolation, 50kHz bandwidth
MA-P09/12/15
power supply modules ±9V/ ±12V/±15V
6.2
Plug-in Cassettes (AMS-K Line)
The amplifier system can individually be equipped with 8 plug-in cas-
settes (or 16 with option
AMS-EXT8
, see chapter 0).
Each cassette is equipped with the relevant 5B module and suitable
input connector.
The suitable input connector on the front panel guarantees for the re-
levant connection to be available when exchanging the cassette.
The following cassettes are available:
6.3
AMS-HANDLE2
For mobile use, the AMS42-LAN16fx can be equipped with two stable me-
tal handles at the housing frame (
AMS-HANDLE2
).
6.4
AMS-EXT8, AMS-DIG8
With the add-on option
AMS-EXT8
, the analog inputs 9..16 are
available as amplifier inputs, and eight opto-isolated digital inputs and
eight relay outputs with the option
AMS-DIG8
.
Product
Description
AMS-K-BIN5
cassette with panel and 5-pin Binder female connector (712 series)
AMS-K-BLANK blank panel
AMS-K-BNC
cassette with front panel and BNC female connector
AMS-K-CO5
cassette with front panel and 5-pin terminal connector
AMS-K-THK
cassette with front panel and thermocouple socket (type K)
Via Paolo Uccello 4 - 20148 Milano