background image

InH2

®

 

Heated Humidifier

 User Manual V2.7

 

8/13 

English 

EMC Requirements

 

Guidance and manufacturer's declaration - electromagnetic emissions 

The RESmart

®

 is intended for use in the electromagnetic environment specified 

below. The user of the RESmart

®

 should ensure that it is used in such an 

environment. 

Emissions Test

 

Compliance

 

Electromagnetic environment - 
guidance

 

RF emissions 
CISPR 11 

Group 1, 
Class B 

The RESmart

®

 uses RF energy only for its 

internal function. Therefore its RF 
emissions are very low and are not likely 
to cause any interference in nearby 
electronic equipment. 

RF emissions 
CISPR 11 

Group 1, 
Class B 

The RESmart

®

 is suitable for use in all 

establishments including domestic 
establishments and those directly 
connected to the public low-voltage power 
supply network that supplies buildings 
used for domestic purposes. 

Harmonic emissions
IEC 61000-3-2 

Class A 

Voltage fluctuations
/flicker emissions 
IEC 61000-3-3 

Class D 

 

 
 

 

 

 
 

 

 

 

 
 

 

 

 
 

 

 

Содержание INH2

Страница 1: ...English InH2 Heated Humidifier User Manual 0123...

Страница 2: ...er is only used for single patient and must not be re used on another person This is to avoid the risk of cross infection The InH2 Heated Humidifier is not intended for use with a patient whose upper...

Страница 3: ...only accessories recommended by BMC Never operate the humidifier if any of the parts are damaged if it is not working properly or if the humidifier has been dropped or mishandled Do not use the humidi...

Страница 4: ...indicates the maximum water level for safe operation Outlet Port Connect the flexible tubing coaxial 22 mm here Water Chamber The removable water chamber holds the water for humidification It has a s...

Страница 5: ...ector Plug this connector into the power outlet on the BMC RESmart Device Set Up 1 Connect the Humidifier to the RESmart device Make sure they are connected completely 2 Place the RESmart device and h...

Страница 6: ...ifier will work automatically The yellow indicator light on the humidifier will turn on Press the humidifier button can turn off or restart the humidifier 5 The ideal humidity setting depends on room...

Страница 7: ...mes with clean water and allow to air dry 4 Fill the water chamber and close the silica gel cover Inspect the water chamber for any leak or damage Replace the water chamber if any damage is present Hu...

Страница 8: ...condensing Atmospheric Pressure 860 to 1060 hPa 500 to 1060 hPa Power Requirements 24V DC 1 0A max Type of Protection Against Electric Shock Class II Equipment Degree of Protection Against Electric Sh...

Страница 9: ...the System When traveling the optional CPAP carrying case is for carry on luggage only The carrying case will not protect the humidifier if it is put through checked baggage Security Stations For eas...

Страница 10: ...missions CISPR 11 Group 1 Class B The RESmart uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic eq...

Страница 11: ...for power supply lines 1 kV for input output lines Mains power quality should be that of a typical home or hospital Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2...

Страница 12: ...re than is indicated in the device specification it may be necessary to position the RESmart further from sources of power frequency magnetic fields The power frequency magnetic field should be measur...

Страница 13: ...nications equipment should be used no closer to any part of the RESmart including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transm...

Страница 14: ...adio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey sh...

Страница 15: ...ive material or part BMC Medical Co Ltd will pay customary freight charges from BMC Medical Co Ltd to the dealer location only This warranty does not cover damage caused by accident misuse abuse alter...

Отзывы: