Software installation and configuration 

 

All software and documentation available for the AMS42/84-LAN are integrated on the "Software 
Collection" CD included with delivery. When inserting the CD, a CD starter opens automatically 
(otherwise: start 

openhtml.exe

). 

 

AMS42-LAN

 

Change to the product page of the AMS42/84-LAN by selecting the entry "Products" in the CD 
starter and then the hardware ("AMS42-LAN" or "AMS84-LAN") listed under the interface 
"LAN". 

 

For detailed information about installing or operating the software, please see the corresponding 
manuals. The Adobe Acrobat Reader is required to open the documentation in PDF format. 

 

You can run the installation directly from CD. If your browser prevents this, first save the 
setup program to hard disc before running it separately. 

 

Software  Software product  Notes 

Documentation 

Configura-
tion 

iM-Admin

 

free software for the configuration of bmcm 
LAN data acquisition systems 

UM-iM-Admin

 

(user manual) 

Program-
ming 

STR-LIBADX

 

ActiveX control for hardware independent pro-
gramming 

STR-LIBADX-IG

 

(installation / programming manual)

 

STR-LIBADX-EX

  example programs for LIBADX ActiveX control - 

 

SDK-LIBAD 

SDK with example programs for C/C++ on 
Windows

®

, MAC OS X, FreeBSD, Linux 

SDK-LIBAD-IG

 

(installation / programming manual)

Operating 
program 

NV4

 

measuring software NextView

®

4 available in the 

Standalone versions:  

 

Lite:  

"slim" version with basic functions 

 

Pro:  

full version with complete functional 
range 

 

Analysis: version for the analysis of stored 

measuring data 

NextView

®

4 can be used for free as a fully func-

tional 30-day trial version. After purchasing the 
software, all projects, measurement files, and 
settings can still be used. 

 

NV4-SRV 
NV4-WORK

 

Client/Server version of NV4 consisting of 
NextView

®

4 Server and NextView

®

4 Work-

station 

DS-NV4

  

(data sheet) 

UM-NV4

  

(user manual) 
"

First steps

" in the NextView

®

demo project (displayed when first 
starting the software) 

 

6.1

 

Configuration with iM-Admin 

  Network settings, firmware version and connection quality of the AMS42/84-LAN can be tested or 

changed with the configuration software 

iM Admin

 

The data acquisition unit integrated in the AMS42/84-LAN is an iM-AD25a. This name is al-
ways used and displayed in the software. 

6.1.1

 

Installation 

The installation program for the configuration software 

iM Admin

 is included on the AMS42/84-LAN prod-

uct page of the "Software Collection" CD. During installation, you will be prompted to choose the desired 
program group, to open the 

iM Admin

 via the Windows

®

 Start menu, and the directory path, in which the 

software is to be installed.  

Содержание AMS42/84-LAN

Страница 1: ...e and be integrated in the AMS Clearly safe The galvanic isolation provided by the 5B mod ules guarantees interference free operation and protects the DAQ system and the PC against high potentials 8 1...

Страница 2: ...be prepared first before attaching the device to the rack system with screws 1 2 Software installation and start up procedure a Connect an external power unit to the 3 pole DIN coupling for 9 40V pow...

Страница 3: ...K flashing device on waiting for connection to software transmission of data on device on connection to software connection to hub off device off no connection to hub NextView 4 or LIBAD4 not iM Admin...

Страница 4: ...sepa rately if possible Measurements can be effected on various potentials The potential deviations however should not ex ceed 60V DC according to VDE Association of German Electrical Engineers 3 6 Sy...

Страница 5: ...outputs Serial resistors in the output lines limit the current and protect the hardware from being destroyed 4 1 Connecting an LED Only so called low current LEDs can be used because they already work...

Страница 6: ...nment The pin assignment on the right shows the top view of the module back plane see chapter 5 The pin assignment corresponds to the 5B modules of Analog Devices BURR BROWN etc However an additional...

Страница 7: ...for C C on Windows MAC OS X FreeBSD Linux SDK LIBAD IG installation programming manual Operating program NV4 measuring software NextView 4 available in the Standalone versions Lite slim version with...

Страница 8: ...pant of the network has his own IP address consisting of four groups of numbers To guarantee that a data package arrives at the correct address this IP address must have been given out only once Each...

Страница 9: ...ming the AMS42 84 LAN under Max OS X and Unix FreeBSD Linux with C C is done by means of the LIBAD4 programming interface The SDK LIBAD for the respective operating system also Windows is included on...

Страница 10: ...ogram NextView 4 different versions Demo Live Lite Professional Analysis Client Server available unlimited number of devices even of different type can be installed except for NextView 4 Lite configur...

Страница 11: ...ally equipped with 8 AMS42 LAN or 16 AMS84 LAN or AMS42 LAN with option AMS EXT8 plug in cassettes Each cassette is equipped with the relevant 5B module and suitable input connector The suitable input...

Страница 12: ...Frequency accuracy Frequency drift max 100ppm max 50ppm C The total sampling rate is the sum of the sampling rates of the individual used channels e g if 5 channels are scanned with 1kHz the total sa...

Отзывы: