AMS42/84-LAN 

Page 5 

3.7

 

Digital outputs 

The AMS42/84-LAN features 4 digital outputs (

low

: 0V..0.7V; 

high

3.0V..5V). All connections are led to the 15-pole Sub-D female con-
nector on the back of the device. The pin assignment is as follows: 

Pin 

Assignment 

 

Pin 

Assignment 

3 DOut 

 

14 Sync 

IN 

4 DOut 

 

15 Sync 

OUT 

11 DOut 

 

7, 8 

Sync GND 

12 DOut 

  1, 2, 6, 9, 10 

n. c. 

5, 13 

DGND 

 

 

 

 

4

 

Interfacing examples for digital outputs 

Serial resistors in the output lines limit the current and protect the hardware from being destroyed. 

4.1

 

Connecting an LED 

Only so-called low-current LEDs can be 
used, because they already work with 1mA 
current. 
Please also observe the total current listed 
in the technical data (see chapter  ). 

4.2

 

Connecting a relay 

A connected relay is ideal to switch higher 
currents. Since the field coil of the relay 
requires a higher current than provided by 
the measurement system at one line, a tran-
sistor is connected ahead.  
 

 

Relay boards with 8 relays or 16 semi-
conductor relays are available at bmcm. 

Содержание AMS42/84-LAN

Страница 1: ...e and be integrated in the AMS Clearly safe The galvanic isolation provided by the 5B mod ules guarantees interference free operation and protects the DAQ system and the PC against high potentials 8 1...

Страница 2: ...be prepared first before attaching the device to the rack system with screws 1 2 Software installation and start up procedure a Connect an external power unit to the 3 pole DIN coupling for 9 40V pow...

Страница 3: ...K flashing device on waiting for connection to software transmission of data on device on connection to software connection to hub off device off no connection to hub NextView 4 or LIBAD4 not iM Admin...

Страница 4: ...sepa rately if possible Measurements can be effected on various potentials The potential deviations however should not ex ceed 60V DC according to VDE Association of German Electrical Engineers 3 6 Sy...

Страница 5: ...outputs Serial resistors in the output lines limit the current and protect the hardware from being destroyed 4 1 Connecting an LED Only so called low current LEDs can be used because they already work...

Страница 6: ...nment The pin assignment on the right shows the top view of the module back plane see chapter 5 The pin assignment corresponds to the 5B modules of Analog Devices BURR BROWN etc However an additional...

Страница 7: ...for C C on Windows MAC OS X FreeBSD Linux SDK LIBAD IG installation programming manual Operating program NV4 measuring software NextView 4 available in the Standalone versions Lite slim version with...

Страница 8: ...pant of the network has his own IP address consisting of four groups of numbers To guarantee that a data package arrives at the correct address this IP address must have been given out only once Each...

Страница 9: ...ming the AMS42 84 LAN under Max OS X and Unix FreeBSD Linux with C C is done by means of the LIBAD4 programming interface The SDK LIBAD for the respective operating system also Windows is included on...

Страница 10: ...ogram NextView 4 different versions Demo Live Lite Professional Analysis Client Server available unlimited number of devices even of different type can be installed except for NextView 4 Lite configur...

Страница 11: ...ally equipped with 8 AMS42 LAN or 16 AMS84 LAN or AMS42 LAN with option AMS EXT8 plug in cassettes Each cassette is equipped with the relevant 5B module and suitable input connector The suitable input...

Страница 12: ...Frequency accuracy Frequency drift max 100ppm max 50ppm C The total sampling rate is the sum of the sampling rates of the individual used channels e g if 5 channels are scanned with 1kHz the total sa...

Отзывы: