BMC AMS42/84-LAN Скачать руководство пользователя страница 1

 

 AMS42/84-LAN 

5B amplifier measurement system (LAN) 

 

Functional diagram 

All-In-One Measurement System.  
Compact or 19 inch. 

The AMS42/84-LAN, a complete solution: am-
plifier technology and data acquisition. A net-
work data acquisition system is already inte-
grated. Available in a robust aluminum housing 
as a mobile tabletop unit (AMS42-LAN) with 
skid-proof, tip-up feet or as a stationary version 
(AMS84-LAN) for 19'' rack systems.  

Modular concept.  
Equip individually. Be flexible. 

The AMS device is equipped with cassettes, on 
which the required 5B measuring amplifiers are 
mounted. The variety of available 5B modules al-
lows for the optimum adaptation of the 
AMS42/84-LAN to any special measuring task.  

Choose connector. 
Mount 5B amplifier. Done. 

The available plug-in cassettes have different 
connectors at the front panel. Depending on the 
sensor or signal to be connected, the suitable cas-
sette can be chosen. Now the 5B module only has 
to be fixed on the cassette and be integrated in the 
AMS. 

Clearly safe. 

The galvanic isolation provided by the 5B mod-
ules guarantees interference-free operation and 
protects the DAQ system and the PC against high 
potentials. 

8/16 analog inputs. 25kHz.  
4 digital outputs.  

Signals are connected at 8/16 analog inputs with 
15 bit resolution and 25kHz total sampling rate. 
Digital states can be controlled via four digital 
outputs. 

DAQ via network. Remote.  
Synchronized, if you like. 

The LAN technology of the AMS42/84-LAN al-
lows for measurement applications across great 
distances. The recorded data are transmitted via 
network from arbitrarily many measuring points 
to a server PC. The signals of several devices can 
be synchronized with each other. 

TCP/IP. Guaranteed reliable. 

The TCP/IP protocol stands for reliable data 
transmission - even via the internet. 

Open for everyone. 

Widely supported: The amplifier measurement 
system can be used under Windows

®

 7/XP as 

well as under MAC OS X, Free BSD and Linux. 
The complete software for installation and pro-
gramming of the AMS42/84-LAN is included for 
free. The device is supported by NextView

®

 4, 

the software for data acquisition and analysis. 

Содержание AMS42/84-LAN

Страница 1: ...e and be integrated in the AMS Clearly safe The galvanic isolation provided by the 5B mod ules guarantees interference free operation and protects the DAQ system and the PC against high potentials 8 1...

Страница 2: ...be prepared first before attaching the device to the rack system with screws 1 2 Software installation and start up procedure a Connect an external power unit to the 3 pole DIN coupling for 9 40V pow...

Страница 3: ...K flashing device on waiting for connection to software transmission of data on device on connection to software connection to hub off device off no connection to hub NextView 4 or LIBAD4 not iM Admin...

Страница 4: ...sepa rately if possible Measurements can be effected on various potentials The potential deviations however should not ex ceed 60V DC according to VDE Association of German Electrical Engineers 3 6 Sy...

Страница 5: ...outputs Serial resistors in the output lines limit the current and protect the hardware from being destroyed 4 1 Connecting an LED Only so called low current LEDs can be used because they already work...

Страница 6: ...nment The pin assignment on the right shows the top view of the module back plane see chapter 5 The pin assignment corresponds to the 5B modules of Analog Devices BURR BROWN etc However an additional...

Страница 7: ...for C C on Windows MAC OS X FreeBSD Linux SDK LIBAD IG installation programming manual Operating program NV4 measuring software NextView 4 available in the Standalone versions Lite slim version with...

Страница 8: ...pant of the network has his own IP address consisting of four groups of numbers To guarantee that a data package arrives at the correct address this IP address must have been given out only once Each...

Страница 9: ...ming the AMS42 84 LAN under Max OS X and Unix FreeBSD Linux with C C is done by means of the LIBAD4 programming interface The SDK LIBAD for the respective operating system also Windows is included on...

Страница 10: ...ogram NextView 4 different versions Demo Live Lite Professional Analysis Client Server available unlimited number of devices even of different type can be installed except for NextView 4 Lite configur...

Страница 11: ...ally equipped with 8 AMS42 LAN or 16 AMS84 LAN or AMS42 LAN with option AMS EXT8 plug in cassettes Each cassette is equipped with the relevant 5B module and suitable input connector The suitable input...

Страница 12: ...Frequency accuracy Frequency drift max 100ppm max 50ppm C The total sampling rate is the sum of the sampling rates of the individual used channels e g if 5 channels are scanned with 1kHz the total sa...