BMB
8/10
e-mo-desk, two engines, 600-1250mm / 700-1200mm
Art.-No. 4884.617, 4884.618, 4884.666, 4884.688,
4884.717, 4884.718, 4884.766, 4884.788
This base is designed to go to its minimum and maximum heights, allowing for the widest possible
range. If you prefer to change the settings to a more narrow range, follow these steps:
Make sure the power is ON and a number reads in the LED display (if no number appears, please follow
the Reset procedure described in the USE section).
To set the upper limit position:
Use the UP/DOWN buttons to move the base to the desired maximum height position. Make sure the
UP button was the last button you pushed. Press the M button and release. Press the UP button and
release. The LED display will flash "S -". Press and hold the M button (about 2 seconds) until the LED
display changes to "999". The display will automatically return to the selected height. The new upper
limit is now set.
To set the lower limit position:
Use the UP/DOWN buttons to move the base to the desired minimum height position. Make sure the
DOWN button was the last button you pushed. Press the M button and release. Press the DOWN button
and release. The LED display will flash "S -". Press and hold the M button (about 2 seconds) until the
LED display changes to "000". The display will automatically return to the selected height. The new
lower limit is now set.
To remove the upper/lower limit positions:
Use the UP or DOWN button to move the desk to any new position. Press and hold the M button until
the LED display flashes "S -" and release. Within 5 seconds, press and hold the M button again (about
2 seconds) until the LED display changes to "555". After a few seconds, the display automatically will
change back to the numbered height position. The upper and lower limits are now removed.
After the upper and lower limits are set, the previous memory positions (1, 2, 3, 4)
may be outside the new range of movement. If so, simply reset the memory positions.
If you attempt to revise a previously set upper or lower limit and it is outside of the
existing range, you will need to remove the previously set upper/lower limits first.
SETTING THE UPPER AND LOWER LIMITS
(some models)
To lock the handset:
Press and hold the M button (about 8 seconds) until the LED display switches to "S-" and then to "LOC".
Release the button. The handset is now locked.
To unlock the handset:
Press and hold the M button (about 8 seconds) until the LED display switches from "LOC" to the height
display. Release the button. The handset is now unlocked.
TO LOCK/UNLOCK THE HANDSET
(some models)