5.3     WEEKLY MAINTENANCE 

 

Weekly maintenance involves cleaning the ashes and combustion residues from inside the 

ash pan of the Boiler and in the Burner. 
This should be done at least every 2/3 days MAX, but can be more or less frequent  

according to the quality of the Pellets used. 

 

Remember also that cleaning frequently inside the combustion chamber positively 

affects the general yield of the Boiler. 

 

During this phase use any ash vacuum cleaner that is equipped with a filter to prevent the 

dust that is sucked in from returning into the environment.  Begin as indicated below: 

Switch off  the machine and  disconnect the power supply  
 
Check that the machine has stopped  and wait for it to cool.  
Open the door of the Boiler, using the handle indicated below.   

 
 
 
 
 
 
 
 
 
 
 

 



Suck in the dust  from the ash space and the brazier of the burner as shown in the figure  

 
 

ENGLISH 

MAINTENANCE 

 

Bmax Technology 

A Division of Elmec Group S.r.l. 

 

Locality: Cà D’Oro 

36020 - Asigliano Veneto (VICENZA) - ITALY 

TEL. +39 0444-772023 - FAX +39 0444-773129  

E-mail: [email protected] - Web: www.b-max.com 

Elmec Group S.r.l. Tax code and VAT no.: 03725780245 

 

B-MAX BOILERS 

ENGLISH 

SAFETY 

 

1.3  PURPOSE OF THE MANUAL 

 

 

The purpose of this manual is to allow the user to take all possible, necessary measures 
and to set up all the machinery and materials in such as a way as to ensure the correct and 
safe use of the equipment.  

 

 

The present manual is in conformity with the latest regulations at the time of release onto 
the market. It does not consider the machinery already on the market with its relative 
tecnical documentation, deficient or inadeguate, if eventual modifications or adjustments 

or are made or new technologies on new machines on the market are applied. The  
information in this manual must be scrupulously evaluated and observed, and is all  
necessary for the correct installation, use and maintenance of the boiler.  

 

Therefore, this manual must be carefully stored for consultation, any time there are doubts 
or problems. The use and instructions manual is an integral part of the boiler equipment.  
If the boiler is sold to another person, it is obligatory to consign the manual to the new  
purchaser.  
If it is lost, it is possible to request a new copy from the manufacturer.  
 
 

1.4  RESPONSIBILITY OF THE MANUFACTURER 
 

On consignment of this manual,  

BMax

  

declines all responsibility, either civil or cri-

minal, direct or indirect, due to:  

 



Accidents caused by the NON OBSERVANCE of the regulations and specifications  

present in this manual  



Accidents caused by an IMPROPER AND INCORRECT USE of the machinery on the part 

of the user  



Accidents caused by modifications and repairs carried out by technicians that are not  

authorised by 

BMax 

 



Inadequate MAINTENANCE 



Exceptional events 



Accidents caused by the use of non-original spare parts or parts that are not specific to the 

model in question   

 

For installation operations, the installer is, and remains,  

solely responsibile. 

  

 

  

Содержание B-MAX 100

Страница 1: ... 773129 E mail info b max com Web www b max com Elmec Group S r l Tax Code and VAT no 03725780245 THE PRESENT MANUAL FORMS AN INTEGRAL PART OF THE BOILER AND MUST BE KEPT FOR FUTURE REFERENCE Pellet Boilers BEFORE USING THE BOILER IT IS OBLIGATORY TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS Instructions for Use and Maintenance ...

Страница 2: ...Manufactured Products Directive 2006 42 CE Machinery Directive ANY MODIFICATION OF THE BOILER WITHOUT THE PRIOR CONSENT OF Elmec Group S r l WILL RENDER THIS DECLARATION NULL AND VOID SPACE FOR MACHINERY IDENTIFICATION PLATE Elmec Group S r l Location Cà D Oro 36020 Asigliano Veneto VICENZA ITALY Date 01 02 2014 Managing Director Rev 00 Date 28 05 2014 B MAX BOILERS NOTES ENGLISH Bmax Technology a...

Страница 3: ...S r l Tax code and VAT no 03725780245 B MAX BOILERS Dear Customer We thank you for choosing our product The B max Pellet Boilers can be connected to any type of heating system to Radiators Floor Skirting etc Our boilers have been exclusively studied to operate with wood pellets DIN quality 6 mm diameter Its structure is similar to a traditional wood boiler but it is far more economical It is extre...

Страница 4: ...quirements indicated in the present Manual and in particular must Never use the system for purposes other than those indicated in this manual Always carry out constant diligent Maintenance as indicated in the various chapters Follow the safety regulations currently in force in the state in which the boiler is installed Never tamper with the plant Only use genuine spare parts Ensure that the instal...

Страница 5: ...IT TO THE SMOKE EXHAUST ON THE BOILER Always use the safety devices and individual protection devices required in accordance with EEC Directive 89 391 Disconnect thepowersupplybeforecarryingoutanyoperations Always use suitable tools Before starting any work make sure that the combustion chamber is cold and that the ash is cold Also wait for the opening handles to cool down before touching them No ...

Страница 6: ...e following characteristics diam 6 mm max length 30 mm humidity 8 9 Do not use the Boiler as an incinerator Carry out all operations with the maximum concern for safety 17 Bmax Technology A Division of Elmec Group S r l Locality Cà D Oro 36020 Asigliano Veneto VICENZA ITALY TEL 39 0444 772023 FAX 39 0444 773129 E mail info b max com Web www b max com Elmec Group S r l Tax code and VAT no 037257802...

Страница 7: ...essary measures and to set up all the machinery and materials in such as a way as to ensure the correct and safe use of the equipment The present manual is in conformity with the latest regulations at the time of release onto the market It does not consider the machinery already on the market with its relative tecnical documentation deficient or inadeguate if eventual modifications or adjustments ...

Страница 8: ...no Veneto VICENZA ITALY TEL 39 0444 772023 FAX 39 0444 773129 E mail info b max com Web www b max com Elmec Group S r l Tax code and VAT no 03725780245 B MAX BOILERS 5 0 TRANSPORT and MAINTENANCE 5 1 TRANSPORT The Boiler is delivered on a pallet and protected with bubble wrap or in a wooden box for larger models Transport loading and unloading Transport loading and unloading must be carried out wi...

Страница 9: ...the safety devices or on parts of the Boiler or Burner 4 2 FIRST START UP AND SHUT DOWN When starting for the first time some of the oil and grease that coat the combustion chamber will tend to evaporate The room must be aired to allow these fumes to exit For the Start Up proceed as follows 1 Make sure that the Boiler is connected to the Hydraulic system 2 Connect the Burner to the mains 3 Ignite ...

Страница 10: ...r l Tax code and VAT no 03725780245 B MAX BOILERS 3 7 INSTALLING THE BURNER ON THE BOILER For questions of size distance and safety the Burner is supplied separately from the Boiler To install the Burner follow the instructions below 1 Insert the support collector 2 onto the 4 M8 pins 1 welded onto the Boiler door 2 Fix on the collector 2 using the M8 nuts 3 3 Completely insert the burner into the...

Страница 11: ...o the hydraulic system the heating plant and the boiler must be filled Before this operation it is necessary to check the hardness of the water and of water residue and if needed install for example if there is water with a fixed residue greater than 300 mg l at 180 C a water softener before the entry point of the water supply pipe This will ensure optimal conservation of the inside surfaces of th...

Страница 12: ...tart upoftheplant foradurationofnotlessthan 30minutes tocheckthegeneraloperationalstateoftheequipment When the installation is completed and after the first start up of the plant the installer must consign the following documentation to the client The machine use and maintenance manual if not present inside the machinery The necessary documentation in compliance with existing laws TECHNICAL DESCRI...

Отзывы: