OPERATING MANUAL
19
The brush and vacuum motors automatically turns off when the battery level is at minimum. The remaining
charge can be used to bring the machine to the recharging point.
6.7
Installing the brushes
Before changing brushes turn the key-operated switch in OFF position and remove the key.
a) Disk
b) Make sure the scrubbing deck is in the raised position. Make sure the key-operated switch is in OFF position.
1. Thread the brushes into the seat in the flat plate below the base, turning them so that the three buttons enter into the
notches in the plate itself.
2. Snap turn, clockwise the right one and counterclockwise the left one, in order to push the button towards the
connection spring until it is locked in place.
To avoid floor damages, choose with care the type of brushes and of disks, more suitable for the treated
surface.
6.8
Squeegee inclination
During operation the rear rubber blade must be slightly and uniformly bent back about 5 mm along its entire length.
If it is necessary to increase curvature of the rubber in the central section, the squeegee's body must be inclined
backwards by rotating the related handwheel.
6.9
Recovery tank
Check that the squeegee hose and drain hose are correctly positioned. Check that the plug on the drain hose is screwed.
6.10 Solution tank
Fill with clean water at a temperature that does not exceed 50°C. Add liquid detergent in the amounts and using the
procedures recommended by the detergent manufacturer. Use only a minimal percentage of detergent to prevent
formation of an excess quantity of foam since too much foam may damage the aspiration motor.
Always use low foam detergent. Introduce a small amount of anti-foam detergent in the recovery tank before
starting to work to be sure to prevent foam from being generated. Never use pure acids. Put the refill opening
cover back in place after filling the tank.
6.11 Separated chemical tank with dosing system
If the machine is dotated of a separated chemical dosing system add the chemical inside the tank to use the pre selected
washing programs. The chemical mixing is automatic based on the amount of water preset on the console by the
potentiometer (Nr. 5 of CONTROLS AND INSTRUMENTS).