Using the Calibration button you can access the additional
functionality to calibrate the input and define the cut off
value for noise (Cut Off). For calibration it is necessary to
have a device generating the reference current and voltage.
Calibration is performed on the start of the scale and the full
scale.
Before tapping the set button, be sure to connect a signal
generator with the correct value.
After making the configuration, make sure to log the variables of interest correctly in the
appropriate section.
12.4
Digital inputs
KAPTOR
MINI
can be equipped with four digital meter inputs, individually
configurable. For correct operation, the engineering value of each pulse
received on the input must be specified. In particular applications where it is
necessary to be able to add or subtract the pulse value, it is possible to select
the bidirectionality option on digital 1 and 3. In this way, respectively the digital 2 and 4, will act as a sign
for the totalizer.
Enable
: Enable input.
Pulse value
: value to be totalized for each received pulse.
Average
: time unit, if needed, to calculate average values in
sampling time.
Enable bidirectional
: it is possible to select bidiractional
measurement. Available only for inputs 1 and 3.
Reset totalizators
: it is possible to reset the totalizators and
start a new counting.
To avoid unuseful power consumption, deflag “Enable” if
the digital input is not necessary.
If reset, totalizer cannot be restored.