KAPTOR
MINI
User Manual
Firmware Revision: Flow-V1.3.4 / Standard-V1.0.0 App Revision: Easysetup 1.5.1 Manual Revision: V0.1 dtd 30/03/2020
Страница 1: ...KAPTOR MINI User Manual Firmware Revision Flow V1 3 4 Standard V1 0 0 App Revision Easysetup 1 5 1 Manual Revision V0 1 dtd 30 03 2020...
Страница 2: ...KAPTOR MINI User Manual V0 1 pg 1 B M TECNOLOGIE INDUSTRIALI s r l Via Dell Industria 12 35035 RUBANO PD ITALY Tel 39 0 49 8841651 Fax 39 0 49 8841654 e mail bm bmtecnologie it web www bmtecologie it...
Страница 3: ...KAPTOR MINI User Manual V0 1 pg 2 Documents revision REV Type of Revision Approval Date 01 First Version in English 30 03 2020...
Страница 4: ...ombined mounting bracket 16 5 Case opening and closure 17 6 Power supply 19 6 1 Primary internal battery not rechargeable 3 6V 19 6 1 1 Internal battery replacement 19 6 2 Exernal rechargeable battery...
Страница 5: ...Duplication and association of profiles 39 11 7 Save and Save and upload buttons 40 12 Configuration 41 12 1 Sensors connected to RS485 port 41 12 1 1 RS485 standard 41 12 1 2 RS485 flow 44 12 2 Buil...
Страница 6: ...cs 68 12 11 Service Function 69 12 11 1 Reboot 69 12 11 2 Firmware Update 69 12 11 3 Wi Fi password 69 12 11 4 Set modem profile 70 12 11 5 Battery calibration 70 12 11 6 Factory settings 71 13 Confor...
Страница 7: ...formation included please contact the manufacturer or its local Distributors The manufacturer B M Tecnologie Industriali srl is not responsible for any damages to people or things caused by the misuse...
Страница 8: ...I User Manual V0 1 pg 7 2 1 Manual feasability This manual describes features functions and instructions for using KAPTOR MINI For installation and start up of the sensors please refer to their specif...
Страница 9: ...inputs but it could also be supplied by an external battery connected to a dedicated input to manage sensors with higher power consumption External high capacity battery can be easily removed and rep...
Страница 10: ...ng Digital event inputs for monitoring on off status activation Connection of standard 4 20mA or 0 10V sensors for standard signal recording 3 2 Main applications Water Losses DMAs and measurement of...
Страница 11: ...re sensor Range to be selected in order Connection GAS M DIAGNOSTICS 4 Logic inputs Check case closure Internal case relative humidity Accuracy 2 Resolution 14 bit Internal case temperature Accuracy 0...
Страница 12: ...AL FEATURES of KAPTORMINI CONFIGURATION Through a free of charge AndroidTM app the user can setup the device with a simple and intuitive interface typical of modern apps In the user can download data...
Страница 13: ...twork internal board status CONNECTIVITY TO A REMOTE SERVER Proprietary communication protocol data sending to a remote server using a proprietary communication protocol with http service via GET The...
Страница 14: ...internal clock with that of the server to ensure that multiple instruments can have the same time If enabled time can be synchronized to a remote NTP server CLEANING CYCLES Cleaning cycles for the se...
Страница 15: ...l V0 1 pg 14 4 Dimensions and fixing system KAPTOR MINI was designed to be wall mounted with a bracket made of stainless steel The bracket keeps the device in vertical position in order to reach exter...
Страница 16: ...wall mounting support If you plan to replace the device frequently it is possible to use a wall support that allows the quick release of the mounting bracket Once fixed to the wall with two dowels the...
Страница 17: ...external battery or in other peculiar cases including two devices a combined mounting system is foreseen It consists of two brackets with a coupler The coupler allows two mounting brackets to be hold...
Страница 18: ...the degree of protection IP68 so it is completely normal to find resistance in this phase If so you can help yourself by levering with two flat screwdrivers To close bring the two parts of the case c...
Страница 19: ...atural conditions of deterioration of the O rings In the event of damage it is necessary to replace them by requesting them from the assistance service A drying bag is necessary to remove any residual...
Страница 20: ...different installations Please refer to any additional documentation attached regarding the supplied battery Disassembling the battery pack replacing cells attempting to recharge non rechargeable bat...
Страница 21: ...r 5 Now connect the new battery pack by reconnecting the white connector and screw the holder 6 Close the case After replacing the battery check the device connections 6 2 Exernal rechargeable battery...
Страница 22: ...battery charger RED battery charger is working 4 LED2 RED battery is charging 5 When LED2 turns GREEN battery is completely charged 6 When charging is complete disconnect the battery charger form mai...
Страница 23: ...o not try to charge primary batteries There is a danger of serious damage to property and people due to possible explosions 6 4 External power supply KAPTOR MINI can be supplied by an external source...
Страница 24: ...own in the figure near the internal battery connector 2 Remove the resin on the jumpers if any 3 Follow the diagram to select the power source External Battery Internal Battery 4 Fix the jumpers with...
Страница 25: ...ts to acquire a signal from its own system it is necessary to use the pre wired connector equipped with free cable lugs To connect an external connector 1 Unscrew the cap 2 Hold the connector 3 Place...
Страница 26: ...Yellow Voltage Input AN2 Pink Current Input AN2 Brown GND AN2 DIGITAL INPUT Pink Digital 1 Grey Digital 2 Brown Digital 3 White Digital 4 Blue Common digital GND Red Not Used Green AUX3 Yellow AUX4 R...
Страница 27: ...iguration of the AUX1 4 can only be carried out if its connector is mounted on the instrument The selection of the connectors on the instrument is made during the ordering process according to the pur...
Страница 28: ...access the slot follow these steps 1 Open the case by acting on the external collar 2 Remove the upper cover paying attention to the built in antenna cable if present 3 Unscrew the screws as shown in...
Страница 29: ...Install again the battery pack and the antenna place the upper cover and fix the collar Once the installation of a new SIM has been carried out it is suggested see App communication section SIM to che...
Страница 30: ...remain constantly powered No type of operation is performed to reduce consumption It is possible to connect to the device via App at any time in order to proceed with the configuration or data visual...
Страница 31: ...operator and in order to reduce the energy consumption associated with turning on the modem Data stored will be sent upon reaching the transmission period The transmission frequency must be chosen acc...
Страница 32: ...Blinking reading and logging Red Alarms Fixed active alarm Blinking active alarm Blue Modem Connection Fixed modem is on Blinking modem is sending data Single Blinking every 5 seconds modem is ON Doub...
Страница 33: ...re the ID will be present in place of the x s If multiple devices are connected to the same Wi Fi range multiple networks will be available To access the correct device special attention must be paid...
Страница 34: ...available in Play Store so installation could be forbidden as the tablet could not install software from an unknown source To solve this problem enable installation form unkn own sources by following...
Страница 35: ...guration will not be usable An example of an interface main menu is shown in the figure 11 4 1 App working mode live and off line The App can work both if directly connected to the instrument live mod...
Страница 36: ...his situation it is possible to connect to an instrument or select a profile to check and or modify see dedicated paragraphs below By selecting a profile the block does not change color and the wordin...
Страница 37: ...turning off the screen and pausing the application it is possible to set the keeping of the display active while using the App This setting is effective only when using the application without interfe...
Страница 38: ...ne of interest must be selected If your device is not listed among the available connections pls check its status LEDs to check if it is ready for connection If the list of available connections is em...
Страница 39: ...e EasySetup settings see local profile save settings the option to save the instrument profile locally will be offered 11 6 Profiles management When connecting to an instrument based on the preference...
Страница 40: ...Each point of the canal has a different section Once the instrument is configured for point A it is possible to duplicate the profile named it differently and change the geometry of the channel In the...
Страница 41: ...eful if you want to make multiple changes in multiple configuration tabs before loading the entire profile on the instrument Of the two he is the only one who always remains enabled even in the off li...
Страница 42: ...y performing the firmware update A factory reset is mandatory when switching from one version to another it is necessary to perform a factory reset In this case the data stored on the KAPTOR MINI will...
Страница 43: ...to provide a valid reading after receiving the supply voltage The warm up is significant in the discontinuous operating mode when the power is supplied only for the time strictly necessary for readin...
Страница 44: ...integers with and without sign long and float with different configurations of bytes Slave it is the unique identifier of the slave sensor to be read Multiple sensors with the same identification can...
Страница 45: ...onnected to the port and customize its settings Sensor type choose the type of sensor connected Doppler or TTFM and press Settings for complete configuration Warm up time it is the awakening time expr...
Страница 46: ...ays the data read by the sensor in real time By inserting the measured value with a rod inside the channel the offset value is automatically determined Position from the bottom indicates the sensor in...
Страница 47: ...r sensor to be mounted on a special sleeve refer to the specific sensor manual for further information Critical level level below which the speed is no longer read by the sensor The minimum critical l...
Страница 48: ...nt remains unchanged Max Lev for KsIf eval indicates the maximum acceptable level for the automatic calculation of the KsIf coefficient Above this level the samples read will not contribute to the cal...
Страница 49: ...altitudes The device interpolates linearly obtaining the overall area from the sum of overlapping trapezoids By entering the points the height of the geometry refers to the channel bottom and the wid...
Страница 50: ...asySetup Resume Note Height Width 0 10 15 20 25 30 100 100 1 header line 4 lines No errors Correct File including 4 points Height Width 0a 10 15 20 2e5 30 100 100 1 header line 2 lines Errors in lines...
Страница 51: ...se the device will not be able to communicate with TTFM Entering settings EasySetup will automatically read the configuration of TTFM sensor Transducer distance it is the value of the mounting distanc...
Страница 52: ...d is not included among the standard ones Transducers type it is referring to the type of transducers installed on the pipe It is possible to select them among different types of available transducers...
Страница 53: ...ed flow rate Net difference between positive and negative totalizers Damping it indicates the value in seconds of the damping applied to the display and to the analog signals output from the instrumen...
Страница 54: ...ecial window will open The transducer distance value will be the one to be respected during installation The other parameters automatically updated every second allow immediate feedback on the measure...
Страница 55: ...nd 0 10V user can connect to the desired signal by using the dedicated wires see wiring paragraph Inputs can be configured independently in order to guarantee to be the most suitable to the installati...
Страница 56: ...lly configurable For correct operation the engineering value of each pulse received on the input must be specified In particular applications where it is necessary to be able to add or subtract the pu...
Страница 57: ...an automatic closure of the contacts of a relay in order to control for example a compressor for cleaning a sensor connected to the KAPTOR MINI Activation times and frequency can be configured Cleani...
Страница 58: ...me constraints related to the chosen sampling time and cleaning time By setting the sampling per minute it is easy to guess that a warm up close to or greater than one minute is not possible in these...
Страница 59: ...e right contain eight of the different variables available and for each the corresponding label value read and unit of measure The update is performed every second in order to allow the operator to ha...
Страница 60: ...ission is not active it is normal for 0 to be indicated On the other hand a value of 100 indicates that all the acquired data has already been synchronized Start end date after starting the data downl...
Страница 61: ...o different ways of sending data 1 Through HTTP requests with GET method according to a proprietary protocol 2 By CSV file transfer using FTP protocol The sending protocol over HTTP involves sending s...
Страница 62: ...rver Data page this is the page to which the data stored on the instrument are sent Settings page this is the page to which the instrument configuration data are sent Date synch page page used to perf...
Страница 63: ...er choosing from a list of options The item no transmission is to be selected in case data should not be transferred In case of enabled transmission it is possible to choose what should be sent to the...
Страница 64: ...e event of a transmission error Attempts delay delay in number of samples therefore based on the sampling period before retrying to send an SMS Daily SMS sent it is an unmodifiable counter of the mess...
Страница 65: ...ss point Access Point Name It is specific for the SIM used Through the magic wand you can choose one of the preset APNs Refer to your SIM provider APN user APN password username and password i f reque...
Страница 66: ...to the network The test result provides the operator the network the coverage signal and the registration The test phases are displayed in a window At the end of the test the following information are...
Страница 67: ...alarm relay is relay 1 See the wiring diagram The relay remains active as long as there is at least one active alarm Referring to the figure the first alarm enabled is set to trigger when the battery...
Страница 68: ...e in the event of an active alarm The default sampling period is that of the sampling period menu the sampling period in case of active alarm is the one in the events menu In the event of multiple ala...
Страница 69: ...load as CSV file of the saved events of KAPTOR MINI 12 10 5 Reset alarms This button after confirmation reset all the alarm events 12 10 6 Diagnostics This section includes the diagnostic tools of KAP...
Страница 70: ...ata exchange or another available system refer to the operation of your smartphone tablet remembering exactly the position 2 Access the firmware update menu and using the appropriate button select the...
Страница 71: ...ith a different smartphone or tablet Without the password it is not possible to connect to the instrument 12 11 4 Set modem profile This function is used to read the model the serial code and the firm...
Страница 72: ...sary in some cases of version change to obtain a different functioning of the instrument for example in the transition from the Flow version for the management of TTFM sensors and Doppler to the 485 s...
Страница 73: ...nd band transmission systems Part 52 Specific conditions for mobile radio and auciliary devices communications Electric measuring control and laboratory devices EMC requirements Part 1 General require...
Страница 74: ...KAPTOR MINI User Manual V0 1 pg 73 14 Conformity certificates of manufacturer...
Страница 75: ...KAPTOR MINI User Manual V0 1 pg 74...
Страница 76: ...39 0 49 8841651 int5 e mail bm bmtecnologie it web www bmtecologie it 17 Warranty Warranty is 12 twelve months starting from date of receiveing the device 18 Disposal Please start an environmentally f...
Страница 77: ...A 1B 0 External event 1 2 1 Aux Configuration 3 4 Relay 2A 2B 0 Mode change Externa event 3 1 Pressure Sensor No Sensor 0 0 DCT 132M 6001 6bar 0 6 DCT 132M 1602 16bar 1 6 DCT 132M 2502 25bar 2 5 DCT 1...