background image

8

BATTERY CHEMISTRY SELECTION

Our Battery Chemistry option lets you set the charging profile of batteries 
depending on their chemistry (Calcium, AGM, WET or GEL). This must 
be done to ensure you maintain your battery effectively and maximise its 
performance. To do this:
  Press the mode button – the orange button left of the LEDs - and wait 
until there are no

 

  lights showing
  Press the mode button until you have selected the correct battery type.

GEL

 (max voltage of 14.2V)

Designed specifically for the GEL type batteries. But note that some GEL 
batteries do require a higher voltage and for these the AGM option can be 
used.

AGM

 (max voltage of 14.4)

Designed specifically for the AGM type batteries but as mentioned above 
can be used with GEL types that require a higher voltage.

WET

 (bulk and absorption 14.9 volts, recondition up to 15.8 volts)

Designed specifically for WET type batteries. As such it has a maximum 
charge voltage during bulk and absorption of 14.9 volts and then increases 
to 15.8 volts during the recondition stage.

Calcium

 (bulk and absorption 14.9 volts, equalisation and recondition up to 

15.8 volts)
Designed for calcium batteries that have been discharged deeply and need 
an equalisation charge to ensure a full electrolyte reading. Note – if the 
battery only needs a top up, do so and then use the WET charge mode.

Power Supply

 (constant voltage of 13.8 volts)

When the charger is in this Power Supply mode, the battery charger 
gives a constant voltage of 13.8VDC at up to 10A. This is best used with 
appliances or tools that are drawing power from the battery. See “Power 
Supply” section (page 12).
To adjust between options, press and hold for 3 seconds to select desired 
option.

Содержание BatteryCharge15

Страница 1: ...NTTECHNOLOGY THATPOWERSYOURADVENTURES BM PRO 19 Henderson Road Knoxfield 3180 Victoria Australia Phone 61 3 9763 0962 Fax 61 3 9763 8789 Email sales teambmpro com Web www teambmpro com OWNER SMANUAL B...

Страница 2: ...g power solutions experts The BatteryCharge15 represents a high quality product that will provide years of service Copyright Setec 2016 Disclaimer SETEC accepts no liability for any loss or damage whi...

Страница 3: ...lcium bulk and absorption 14 9V equalisation and recondition up to 15 8V 7 Power Supply constant voltage of 13 8V 7 Adjustable Charge Rate 9 Charging Instructions 12 Step 1 Check the Electrolyte Level...

Страница 4: ...ching of metal objects onto the battery cell does not cause short circuits Remove any personal metal adornment such as a chain watch or ring which could cause short circuits and personal injury If the...

Страница 5: ...charging As well as being able to use this charger on various types of batteries including Calcium AGM Wet and Gel it can also help renew sulphated or drained batteries With the function of automatic...

Страница 6: ...TECTION A three phase temperature protection system has been installed for your safety These are A if increased temperature is detected a fan will be started B if this fails power output is reduced an...

Страница 7: ...tion is present See Fault Codes The second row 4 green LEDs indicates the Battery Chemistry selected See step 5 of Charging Instructions and Battery Chemistry Selection sections The third row 3 green...

Страница 8: ...hat require a higher voltage WET bulk and absorption 14 9 volts recondition up to 15 8 volts Designed specifically for WET type batteries As such it has a maximum charge voltage during bulk and absorp...

Страница 9: ...to charge batteries of different voltage may result in damage to the battery 5 Amp Motorcycle ideal for charging batteries between 5 and 20 ampere hours 10 Amp Car ideal for charging 12v batteries be...

Страница 10: ...on and is constant when complete SOFT CHARGE A non harsh soft introduction of power to the battery to help preserve the battery life The 2nd green LED in the top row flashes to indicate when in Soft C...

Страница 11: ...ealthy charge The 5th green LED in the top row flashes to indicate when in Analysis and is constant when complete RECONDITION If a battery fails to fully charge the next step in the phase is for recon...

Страница 12: ...at is being charged Refer to battery manufacturer s details to confirm type To select type Press the Battery Chemistry mode button for 3 seconds to change options Continue to press the mode button unt...

Страница 13: ...es that there is a fault Refer to Fault Codes Section of this document STEP 7 DISCONNECTING To disconnect from the battery once a full charge has been attained remove mains power to BC15 disconnect th...

Страница 14: ...tput Failure to observe these instructions properly may result in property damage which may be serious depending on the circumstances CAUTION Part No BC15 Type 7 Stage Input nominal 220 240VAC 50Hz In...

Страница 15: ...ant to ensure at least a 10cm clearance between the end plates and the surface it is being fixed to This allows for adequate ventilation and cooling The BC15 is designed for indoor use only and is not...

Страница 16: ...ery charge immediately After 30 seconds the unit will automatically re attempt battery charge After 3 consecutive attempts the unit will remain in the error condition until power cycled or the user to...

Страница 17: ...s We accept no responsibility in addition to our consumer guarantee obligations where a product has been installed incorrectly 4 This warranty does not extend to product failures or defects caused by...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...time data view information including volts and amps time remaining temperature battery status state of charge and battery health Easy installation no mechanical expertise required Works with multiple...

Отзывы: