background image

14

POWER SUPPLY MODE

Connect the 

BC15

 to the mains supply and select Power Supply mode by 

depressing and holding the Charge Rate selection button for 10+seconds 
until the 3rd LED in the bottom row is illuminating constant orange.
Then connect your load being careful to connect the positive and negative 
leads appropriately so that the load and 

BC15

 are not damaged.

Power Supply mode is limited to 10Amp output.

Failure to observe these instructions properly may 
result in property damage, which may be serious 
depending on the circumstances.

CAUTION

Part No.

BC15

Type

7 Stage

Input (nominal)

220-240VAC, 50Hz

Input Power

270W

Nominal Output Voltage

14.6V

Minimum Start Voltage

6V

Output Current (Battery Charge 
Mode)

5/10/15A*

Over Current (Power Supply 
Mode)

15A

Back Drain

<4mA

Deep Cycle

200Ah

Automotive

40-800CCA

Marine

55-900MCA

Types of Batteries

Most types of lead acid batteries 
including GEL, WET, AGM, Calcium

SPECIFICATIONS

* Maximum output may progressively derate above 30° down to half of the rated output at 50°

Содержание BatteryCharge15

Страница 1: ...NTTECHNOLOGY THATPOWERSYOURADVENTURES BM PRO 19 Henderson Road Knoxfield 3180 Victoria Australia Phone 61 3 9763 0962 Fax 61 3 9763 8789 Email sales teambmpro com Web www teambmpro com OWNER SMANUAL B...

Страница 2: ...g power solutions experts The BatteryCharge15 represents a high quality product that will provide years of service Copyright Setec 2016 Disclaimer SETEC accepts no liability for any loss or damage whi...

Страница 3: ...lcium bulk and absorption 14 9V equalisation and recondition up to 15 8V 7 Power Supply constant voltage of 13 8V 7 Adjustable Charge Rate 9 Charging Instructions 12 Step 1 Check the Electrolyte Level...

Страница 4: ...ching of metal objects onto the battery cell does not cause short circuits Remove any personal metal adornment such as a chain watch or ring which could cause short circuits and personal injury If the...

Страница 5: ...charging As well as being able to use this charger on various types of batteries including Calcium AGM Wet and Gel it can also help renew sulphated or drained batteries With the function of automatic...

Страница 6: ...TECTION A three phase temperature protection system has been installed for your safety These are A if increased temperature is detected a fan will be started B if this fails power output is reduced an...

Страница 7: ...tion is present See Fault Codes The second row 4 green LEDs indicates the Battery Chemistry selected See step 5 of Charging Instructions and Battery Chemistry Selection sections The third row 3 green...

Страница 8: ...hat require a higher voltage WET bulk and absorption 14 9 volts recondition up to 15 8 volts Designed specifically for WET type batteries As such it has a maximum charge voltage during bulk and absorp...

Страница 9: ...to charge batteries of different voltage may result in damage to the battery 5 Amp Motorcycle ideal for charging batteries between 5 and 20 ampere hours 10 Amp Car ideal for charging 12v batteries be...

Страница 10: ...on and is constant when complete SOFT CHARGE A non harsh soft introduction of power to the battery to help preserve the battery life The 2nd green LED in the top row flashes to indicate when in Soft C...

Страница 11: ...ealthy charge The 5th green LED in the top row flashes to indicate when in Analysis and is constant when complete RECONDITION If a battery fails to fully charge the next step in the phase is for recon...

Страница 12: ...at is being charged Refer to battery manufacturer s details to confirm type To select type Press the Battery Chemistry mode button for 3 seconds to change options Continue to press the mode button unt...

Страница 13: ...es that there is a fault Refer to Fault Codes Section of this document STEP 7 DISCONNECTING To disconnect from the battery once a full charge has been attained remove mains power to BC15 disconnect th...

Страница 14: ...tput Failure to observe these instructions properly may result in property damage which may be serious depending on the circumstances CAUTION Part No BC15 Type 7 Stage Input nominal 220 240VAC 50Hz In...

Страница 15: ...ant to ensure at least a 10cm clearance between the end plates and the surface it is being fixed to This allows for adequate ventilation and cooling The BC15 is designed for indoor use only and is not...

Страница 16: ...ery charge immediately After 30 seconds the unit will automatically re attempt battery charge After 3 consecutive attempts the unit will remain in the error condition until power cycled or the user to...

Страница 17: ...s We accept no responsibility in addition to our consumer guarantee obligations where a product has been installed incorrectly 4 This warranty does not extend to product failures or defects caused by...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...time data view information including volts and amps time remaining temperature battery status state of charge and battery health Easy installation no mechanical expertise required Works with multiple...

Отзывы: