WATER LEVEL 

Always maintain the water level at least 2” above the water pump but ½” below the hole where the wires 
run through.  When filling the fountain for the first time, you should be ready to add water to the reservoir 
as the fountain begins to circulate the water.  The waterfall feature will continuously lose water due to 
evaporation which varies depending on the climate, humidity, temperature, etc.  The lower the humidity 
and the higher the temperature, the faster the water will evaporate.  Also, water will evaporate faster in 
outdoor fountains as well as larger ones.  IT IS IMPERATIVE THAT THE WATER LEVEL BE 
MAINTAINED AT ALL TIMES.  For the first few months of use, you should monitor the reservoir 
periodically to determine the rate of evaporation but remember that can vary as the seasons change.  A 
dipstick can also be created to help you monitor your water levels if you mark it with safe (high) and low 
marks. 
 
If a pump runs dry the following can happen: 

 

Burned 

out 

pump 

      

 

Residue sprayed on waterfall surface 

 

Spraying from manifold delivery system outside of reservoir, possibly even causing damage to 
floors and surrounding areas 

 

MANIFOLD DISTRIBUTION BAR (Floor fountains) 

The manifold distribution bar is located at the top of the panel and can be seen once the header has been 
removed.  It should be removed, inspected and cleaned every six months or as needed.  You can use a pin, 
pipe cleaner or small wire to clean any debris from the holes.  A long, narrow brush may also be used to 
clean the inside of the pipe.  CLR or any other similar product may be used with a soft bristle brush to 
remove any mineral deposits that may have developed.  DO NOT use CLR or Lime Away on any other 
part of your fountain as it will damage the finish. 
 

FILTER 

To maximize the lifespan of your filter, be sure to keep the reservoir at the recommended water level.  
Remove and thoroughly wash the filter once every three months or as needed. 
 

HARD WATER DEPOSITS 

Over a period of time hard water may cause the glass to develop a hazy or cloudy film on its surface. 
When the glass is completely dry, take a dry soft cloth and wipe or buff the surface in circular patterns. 
You can use any standard glass cleaner, or a solution of vinegar and water, to aid in the cleaning process. 

Protec is the only Bluworld approved product to control mineral deposits and should be used 
anytime hard water is used in the fountain

. See bottle for proper instructions on use. As the water 

evaporates and new water is added, the concentration of minerals in the water increases. Eventually, the 
concentration will become too great for Protec to work properly. Because of this, the water feature should 
be drained every three to four months, or when mineral deposits first appear on the glass or frame. 

Note: A glass cleaner only is recommended in the upkeep of the glass surface.  

 

ALGAE GROWTH 

You will notice algae by a sour odor and/or slimy substance which can be green, red, black or clear. If this 
occurs, remove the rock tray and clean the entire fountain as indicated above.  We also recommend that 
Fountec be added to the water as directed. 

Fountec is the only Bluworld approved product to control 

algae and is available directly from Bluworld. 

 

Содержание WATER WONDERS Waterfall

Страница 1: ...Copyright 2009 Bluworld of Water LLC All rights reserved Waterfall Manual...

Страница 2: ...bmerged This will only have to be done the first time the unit is turned on 6 Using the red or blue handle on the hose valve adjust the flow of the water to the desired effect Too much flow can cause...

Страница 3: ...n the fountain off instead of letting them dry on the fountain FOUNTAIN SHOULD BE LEVEL Make sure your waterfall is always kept level For floor fountains you can try using a shim coin thin plastic etc...

Страница 4: ...also be used to clean the inside of the pipe CLR or any other similar product may be used with a soft bristle brush to remove any mineral deposits that may have developed DO NOT use CLR or Lime Away...

Страница 5: ...in the water level at least 2 above the water pump but below the hole where the electrical cords run through The pump should be completely submerged underwater and should be checked every 3 4 days 2 F...

Страница 6: ...difference from one end of the bracket to the other you will want to remove the bracket and reinstall it making certain it is level If the difference is minute a shim or tiny wedge can be placed on t...

Страница 7: ...between pump and inlet hose until water flows evenly down the panel The flow valve on Water Wonders fountains Table Tops Bellezzas Piavasco s and Water G ardens is a black disc located on the top of t...

Страница 8: ...the inlet hose The flow valve on Water Wonders fountains Table Tops Bellezzas Piavascos and Water Ga rdens is a black disc located on the top of the pump Turn the valve clockwise to slow the water flo...

Страница 9: ...cut it will need to be replaced 4 Water flow is too strong Locate the water flow control valve between the pump and the inlet hose The flow valve on Water Wonders fountains Table Tops Bellezzas Piavas...

Страница 10: ...imple Green or other appropriate cleaner Be sure detergent is safe to use on the surfaces you are cleaning 4 Waterfall might have scale deposits from water Drain and refill the fountain with fresh wat...