Document #: BPI-PM001-01
13
Fault Conditions and Fault Codes
If there are issues with the operation of the Model 420, the onboard diagnostics will indicate the
nature of the problem.
Display Screen codes are shown in
Error! Reference source not found.
.
Table 2: Display Screen Status Indicator Fault Codes
Display Color
Display Text
Fault
Operation
Action to Take
Green
Background
Bluezone M420
Unit conditions
scrolling
System operating
properly.
Operates
None
Flashing Green
Background
Bluezone M420
Unit conditions
scrolling
Freezing
temperatures
detected, or
Humidity above
threshold
Unit is off and will
power up when
temperature
increases to >0C or
humidity drops
below 85%
Do not run unit in a
freezing
environment.
Yellow
Background
Contact
Bluezone
Fan not rotating, or
Humidity sensor
failure, or
Bulb counter failure
Unit automatically
powered down.
Check fan for any
visible obstructions.
Contact Bluezone
Products for
service.
Replace Bulbs,
Unit conditions
scrolling
Bulb life >7,200
hours of operation.
Operates until
8,800 hours of
operation.
Check bulb counter
Order new bulbs
Red Background
Contact
Bluezone
Ozone sensor Trip
Unit automatically
powered down until
sensor resets.
Contact Bluezone
Products
Replace Bulbs
Bulb life at 8,800
operation hours.
Unit automatically
powered down until
bulbs replaced and
counter reset.
Replace bulbs and
reset bulb life
counter.
Содержание 420 Series
Страница 4: ...Document BPI PM001 01 3 Key Components Figure 1 Bluezone Key Components 2 3 5 4 1 6 ...
Страница 7: ...Document BPI PM001 01 6 Figure 4 Wiring Diagram of Model 420 048 Unit ...
Страница 10: ...Document BPI PM001 01 9 Figure 6 Illustration of the Ceiling Mount and Shelf Mount ...
Страница 13: ...Document BPI PM001 01 12 Figure 8 Display Sequence in Time ...
Страница 16: ...Document BPI PM001 01 15 Figure 9 Bluezone Cover Switch and Cover Switch Hole Cover switch hole Cover switch ...
Страница 22: ...Document BPI PM001 01 21 Figure 14 Carefully Slide off Bulb Clips using Nitrile Gloves ...
Страница 23: ...Document BPI PM001 01 22 Figure 15 Completed Bulb Assembly Figure 16 Bulb Counter Reset Button ...
Страница 30: ...Document BPI PM001 01 29 Figure 24 Completed Assembly ...
Страница 32: ...Document BPI PM001 01 31 Figure 26 Shelf Mount Dimensions ...
Страница 36: ...Document BPI PM001 01 35 Figure 32 Screws Installed into Bluezone Muffler and Fan Cover ...
Страница 37: ...Document BPI PM001 01 36 Figure 33 Completely Installed Bluezone Muffler ...