Hardware User Manual - Argos3D-P33X
Last change: 22 June 2017
Version 6
© BECOM BLUETECHNIX 2017
Page 19 | 26
6
Appendix
6.1
Operating Conditions
Symbol
Parameter
Min
Typical
Max
Unit
V
IN
Input supply voltage
18
24
30
V
I
IN
Input current
1,25
1)
3,75
3)
A
T
Operating Temperature
2)
0°
50°
°C
T
Storage Temperature
-40
+85
°C
FITP
4)
Frame-rate Integration Time Product
420
IP
Ingression protection
IP41
5)
Table 6-1: Operating Conditions
1) Note
Valid for a typical operation condition: frame-rate of 40fps, an integration time of 1500µs and
24V input voltage supply. The input current depends on the applied frame-rate, integration
time and input supply voltage.
2) Note
The maximum operating temperature depends on the frame-rate and integration time.
3) Note
On maximum FIT and minimum power supply voltage.
4) Note
Framerate Integration-time Product
5) Note
In preferred mounting situation
6.1.1
Input current
The input current depends on the selected frame-rate (fps) and the integration time (t
INT
). The following figure
shows typical values. The values for the x axis shows the FITP which has been calculated with the following
equation:
𝐹𝐼𝑇𝑃 = 𝑡
𝐼𝑁𝑇
[𝑚𝑠] ∙ 𝑓𝑝𝑠 [
1
𝑠
] ∙ 4
TBD
Figure 6-1: Input power depending on frame-rate integration time product