OPERATION
10
24” Battery Automatic Scrubber (06--04)
7. Slowly twist the drive roll grips forward to begin
scrubbing.
To increase drive speed, press and hold speed
thumb lever and twist roll grips further ahead.
(Figure 15).
FIG. 15
8. View amount of solution flow on floor and adjust
solution control lever to desired solution flow.
WHILE OPERATING MACHINE
FOR SAFETY: When using machine, go slow on
inclines and slippery surfaces.
1. Periodically check for foam buildup in recovery
tank (look through clear lid). If heavy foam buildup
begins to develop, pour a defoamer chemical into
the recovery tank.
ATTENTION: Do not allow foam or water to enter
float shut-off screen, vacuum motor damage will
result; not covered by warranty. Foam will not
activate float shut-off screen.
WARNING: Flammable materials or reactive
metals can cause explosion or fire. Do not pick
up.
2. If more scrubbing pressure is needed for small
heavily--soiled areas, simply pull brush lift lever
upward (Figure 16).
FIG. 16
3. If squeegee leaves streaks, raise squeegee and
wipe both blades with a cloth.
4. Before stopping or turning machine around, pull
back on solution control lever to shut off solution
flow.
5. If you have to stop for more than three seconds,
shut off brush switch.
6. View clear tube gallon marker for remaining
cleaning solution left in solution tank.
7. Periodically check battery meter’s discharge level.
When needle drops to the red zone, recharge
batteries.
ATTENTION: Do not operate machine with battery
meter in red zone, battery damage will result.
8. When the solution tank runs dry, turn off brush
switch, shut off solution control lever and continue
to vacuum until all dirty water is consumed into the
recovery tank. Raise the squeegee and brush
head and drain recovery tank (See DRAINING
TANKS).
PAD MOTOR CIRCUIT BREAKER
Machine is equipped with a circuit breaker to protect
pad motor from damage. If the pad motor circuit
breaker trips, it cannot be reset immediately.
Determine reason why breaker tripped, allow motor to
cool and then reset. Circuit breaker will trip due to
excessive overload on pad. Clean or change pad if
breaker should trip. Pad motor circuit breaker button is
located at rear of control console.