S D S 2 0 0 P I P E D R A I N C L E A N E R
6
Ø
Rubber Safety Hose Operations
o
The rubber safety hose is attached to the back of the clutch channel. See figure below.
o
CAUTION: The rubber safety hose must be installed. It protects the user from potential
“whipping” action of the end of the sectional cable. Without it installed, damage to persons or
property are possible.
Ø
Drain cutter operations
o
The drain cutters attach to the end of the drain cleaner cable. These are only attached on the
front side of the machine cable.
o
Attach the drain cleaner cutter once the end of the cable has been inserted into the front of the
machine clutch channel.
§
Insert cutter and head facing T groove. The cutter will only install in one direction.
Push in the cutter until the pin locks the coupling.
§
To remove the cutter, use the key (straight metal pin with sharp flat side). Put the key in
the hole on the cutter until the pin depresses. When it is depressed, the cutter should
slide out of the T groove.
o
There are a variety of drain cutters available for these units (see cutter/accessory table below).