Chart 5.2 Function Detail List (Cont’d)
Function
Code
Name
Setting Range
Min Unit
Factory
Default
Setting
Group F1 Motor Parameters
F100
Motor Type
1: Asynchronous 0: Synchronous
1
1
F101
Motor Pole
0~100
1
0
F102
Motor Rated Frequency
0~99.99Hz
0.01Hz
50.00Hz
F103
Motor Rated Power
0~750W
1W
500W
F104
Motor Rated Speed
0~9999rpm
1
940rpm
F105
Motor Back EMF
0~999V
1
280V
F106
Motor Phase Inductance
0.00~99.99mH
0.01
16.1mH
F107
Motor Phase resistance
0.00~99.99mΩ
0.01
2.4mΩ
F108
Motor Rated Current
0.000~9.999A
0.001A
1.0A
F109
No-load Current
0.000~9.999A
0.001A
0.6A
F110
Slip Frequency
0.000~9.999Hz
0.001Hz
3.000Hz
F111
Motor Rated Voltage
0~220V
1V
50V
Group F2 Performance Control Parameters
F200
Speed Loop K
P
0~9999
1
1000
F201
Speed Loop K
I
0~9999
1
600
F202
Current Loop K
P
0~9999
1
6000
F203
Current Loop K
I
0~9999
1
3000
F204
Speed Filter Grade
0~9999
1
10
F205
Encoder Pulses
0~9999
1
600
F206
Door-open Torque
Promotion
0~30% (Motor Rated Torque)
0.1%
0.0%
Group F3 Door-open Running Parameters
F300
Door-open Start Low-
speed
0~F303
0.01Hz
3.00Hz
F301
Door-open Start
Acceleration Time
0~999.9s
0.1s
0.4s
F302
Door-open Low-speed
Running Time
0~999.9s
0.1s
0.4s
F303
Door-open High Speed
0~F102
0.01Hz
15.00Hz
F304
Door-open Acceleration
Time
0~999.9s
0.1s
0.4s
F305
Door-open End Low-
speed
0~F303
0.01Hz
3.00Hz
F306
Door-open Deceleration
Time
0~999.9S
0.1s
0.4s
F307
Door-open Torque
Switchover Point
0~300.0% Motor Rated Torque
0.1%
50.0%
F308
Door-open Run Torque
0~150.0% Motor Rated Torque
0.1%
80.0%
F309
Door-open Block Torque
0~350.0% Motor Rated Torque
0.1%
120.0%
F310
Door-open Start Torque
0~200.0% Motor Rated Torque
0.1%
80.0%
F311
Door-open to the point
Low-speed
0~F303
0.01Hz
3.00Hz