Limited Warranty and Warranty Claims 

 
BlueCom AG warrants each new product manufactured and sold by it to be free from defects 
in  material,  workmanship  and  construction,  except  for  batteries,  fuses,  or  other  material 
normally  consumed  in  operation  which  may  be  contained  therein,  for  a  period  of  one  year 
after shipment to the original purchaser (which period is referred to as the “warranty period”). 
This warranty shall not apply if the product is used contrary to the instructions in its manual 
or is otherwise subjected to misuse, abnormal operation, accident, or repairs or modifications 
that have not been performed by BlueCom. BlueCom is not responsible for products which it 
does not manufacture. 
 
BlueCom’s  obligation  under  this  warranty  is  limited  to  in-factory  servicing  and  repairing,  at 
BlueCom’s option, the product or the component thereof which is found to be defective. If in 
BlueCom’s judgment the defective condition in a BlueCom product is for a cause listed above 
for  which  BlueCom  is  not  responsible,  BlueCom  will  make  the  repairs  or  replacement  of 
components and charge its then current price, which buyer agrees to pay. 
 
BlueCom  shall  not  be  responsible  if  the  following  procedure  for  warranty  claims  is  not 
followed.  BlueCom  shall  be  notified  of  the claim  with  full  information  as the  claimed  defect. 
BlueCom  products  shall  not  be  returned  unless  a  return  authorization  number  is  issued  by 
BlueCom.  BlueCom  products must  be  returned with  the  description  of  the  claim  defect  and 
identification  of  the  individual  to  be  contacted  if  additional  information  is  needed.  BlueCom 
products must be returned properly packed with transportation charge prepaid. 
 
Except  for  the  limited  warranty  stated  above,  BlueCom  disclaims  all  warranties  of  any  kind 
with regard to BlueCom products or other materials provided by BlueCom, including without 
limitation any implied warranty of merchantability or fitness for a particular purpose. BlueCom 
shall have no liability or responsibility to the original customer or any other party with respect 
to any liability, loss or damage caused directly or indirectly by any BlueCom product, material 
or  software  sold  or  provided  by  BlueCom,  BlueCom  replacement  parts  or  units,  or  service 
provided by BlueCom, including but not limited to any interruption of service, excess charges 
resulting from  malfunctions  of  hardware  or  software,  loss  of  business  or  anticipatory  profits 
resulting  from  the  use  or  operation  of  the  BlueCom  product  or  software,  whatsoever  or 
howsoever caused, and in no event shall BlueCom be liable for any direct, indirect, special or 
consequential  damages  whether  the  claims  are  grounded  in  contract,  tort  (including 
negligence), or strict liability. 
 
 

Rights to Software 

 
BlueCom  retains  ownership  of the  software  supplied  with  this  equipment  and  all  copyrights 
for  the  software.  This  software  may  be  stored  in  the  integrated  circuits  or  in  machine  or 
human  readable  form.  BlueCom  grants  only  a  non-exclusive  license  to  buyer  to  use  the 
software solely in connection with the normal and customary use of the equipment supplied 
to  buyer  under  this  order.  Buyer  agrees  not  to  read  out  the  software  from  the  integrated 
circuits and disclose or make any use of such software other than the use allowed under this 
license. 

Содержание PLTS

Страница 1: ...BCPT1010 SD E2 doc Rev 1 0 BlueCom Ltd PLTS System Description Party Line Telephone System...

Страница 2: ...red or should any user wish to make a suggestion for improving this handbook he is invited to send the relevant details to BlueCom Ltd Giessenstrasse 15 8953 Dietikon SWITZERLAND Telephone 41 44 748 4...

Страница 3: ...defect and identification of the individual to be contacted if additional information is needed BlueCom products must be returned properly packed with transportation charge prepaid Except for the lim...

Страница 4: ...Light Emitting Diode 10 4 J3KA Programming 11 4 1 Supply Voltage Range 11 4 2 Gain Range 11 4 3 Factory Programming 11 5 J3KA Technical data 12 5 1 Supply 12 5 2 Inputs 12 5 3 Outputs 12 5 4 Amplifier...

Страница 5: ...phically seperated stations and one or several local drops to subcriber telephone sets within a station The trunk path may consist of any combination of radio pilot cable microwave fibre or power line...

Страница 6: ...ABB MES standard Each bridging amplifier has its connecting cable V9CT The circuitry is arranged on three printed circuit boards which are designated Na Nb and Nc Na is the main board It is fitted wi...

Страница 7: ...and maintenance of a system the frontpanel of the bridging amplifier is equipped with the following Testpoints on inputs and outputs Potentiometers for level adjustments A light emitting diode LED for...

Страница 8: ...am L M H 1 2 1 3 1 4 14 16 1 3 5 7 27 25 Output 1 Input 1 L M H 2 1 2 3 2 4 17 19 4 6 11 13 31 29 Output 2 Input 2 L M H 3 1 3 2 3 4 20 22 7 9 15 17 35 33 Output 3 Input 3 L M H 4 1 4 2 4 3 23 25 10 1...

Страница 9: ...front end computer in a system control center 3 3 J3KA Testpoints Interruptible testpoints U links are provided on all inputs and outputs which permit bridged in circuit measurements The U links can b...

Страница 10: ...to output 4 Group 2 controls signals from input 2 Potentiometer 1 to output 1 Potentiometer 2 to output 3 Potentiometer 3 to output 4 Group 3 controls signals from input 3 Potentiometer 1 to output 1...

Страница 11: ...n Range In addition to the adjustment by the potentiometers described in 3 4 three coarse gain ranges are provided for each output The range selection can be made by means of jumpers located on the Nb...

Страница 12: ...edance 600 balanced Return loss 300 3400 Hz 14 dB Maximum output level 48 V supply 16 dBm 24 V supply 10 dBm 5 4 Amplifier Gain Continuously adjustable by means of multiturn potentiometers Ranges low...

Страница 13: ...1999 13 5 5 Ambient condition Operating range 0 55 C Transportation and storage 20 55 C Humidity non condensing max 90 5 6 Mechanical Type printed circuit board 3 5 ASA units high 3 divisions wide Cod...

Страница 14: ...ging amplifiers J3KA Connect the SETEL phones to the V9CT cables Interconnect the unit with the communication system via the V9CT cable delivered with each bridging amplifier J3KA 7 3 Installation Con...