B.
‘.GSD’ File
;*************************************************************************
;*** ***
;*** Filename: HIL_0a12.GSD (c) 2007 ***
;*** GSD file version 1.000 from 10.12.2007 ***
;*** ***
;*************************************************************************
;
;ATTENTION:
;==========
;Changes in this file can cause configuration or communication problems.
;This file is compatible to the firmware of the device.
;
;Changes
;=======
;10.12.07 V1.000 R. Hornung
;- created
#Profibus_DP
GSD_Revision = 5
Vendor_Name = "Hilscher GmbH"
Model_Name = "NETX DP/DPS"
Revision = "Version 1.000"
Ident_Number = 0x0A12
Protocol_Ident = 0
Station_Type = 0
Hardware_Release = "Version 1.000"
Software_Release = "Version 2.000"
Implementation_Type = "netX"
9.6_supp = 1
19.2_supp = 1
45.45_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_45.45 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
Redundancy = 0
Repeater_Ctrl_Sig = 2
24V_Pins = 0
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Auto_Baud_supp = 1
Set_Slave_Add_supp = 0
Min_Slave_Intervall = 6
Modular_Station = 1
Max_Module = 24
Max_Input_Len = 244
Max_Output_Len = 244
Max_Data_Len = 488
Max_Diag_Data_Len = 244
Max_User_Prm_Data_Len = 5