BLUEBOX Gen.2 HFM
Page 28 of 37
Byte
Value
Description
Notes
...
0x..
Memory Size – Block Size in bytes
0x00 (1 byte) ... 0x1F (32 bytes)
Present only if bit 2 of Info
Flags is set
...
0x..
Memory Size – Number of Blocks
0x00 (1 block) ... 0xFF (256 blocks)
Present only if bit 2 of Info
Flags is set
...
0x..
IC Reference
Present only if bit 3 of Info
Flags is set
3.24
ISO 15963 Transponder ‘General Protocol’ Command
This command allows to send any ISO 15693 general format protocol
command (flags field, command code field, parameters fields, application data
fields) to a ISO 15693 transponder and to receive, in case of successfull
operation, the response of the transponder (flag field, parameters fields, data
fields). For more details see the specific transponder data sheet and ISO 15693
protocol. If the ‘continous’ mode is enabled, it will be suspended by the
execution of this command and will be suspended as long as this command is
used; it will be resumed automatically when another type of command will be
executed.
Byte
Value
Description
Notes
1
0x15
Command code
1+1
0x..
Data to send to the tag, 1 st byte
1+i
0x..
Data to send to the tag, i th
byte
i < n
1+n
0x..
Data to send to the tag, n th
byte
n depends on the specific
protocol command
If the command is not successfully executed, the answer is given in short form
through the ‘reply ack’ / ‘reply nak’ flags; otherwise, the
BLUEBOX
answers,
a) if the transponder is not present:
Byte
Value
Description
Notes
1
0x15
Command code
2
0x01
Status no transponder
b) if some error is occurred during the transaction:
Byte
Value
Description
Notes
1
0x15
Command code
2
0x02
Status error
c) if the transponder is present:
Byte
Value
Description
Notes