![Blueair BLMI-300A Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/blueair/blmi-300a/blmi-300a_service-manual_2777163018.webp)
⚫
Error codes : Below error codes will be displayed so technicians can immediately identify
specific malfunctions.
Display
Meaning
E1
Freezing cycle exceeds 60 minutes twice in a row.
E2
Harvest cycle exceeds 25 minutes twice in a row.
E3
Evaporator sensor temperature is over 60
℃
(140
℉
).
E4
Water is not drained during full storage.
E5
Water level sensor continues to detect insufficient water levels.
E6
Evaporator sensor error. (damaged or disconnected).
E7
Main PCB program error.
-
E1 : If the freezing cycle exceeds 60 mins for the first time, the ice machine will
activate the harvest cycle. This is called a
“forced” harvest.
E1 will be displayed if
the same situation happens again.
-
E2 : If the harvest cycle exceeds 25 mins for the first time, the ice machine will
activate the freezing cycle. This is called a
“forced”
freezing cycle. E2 will be
displayed if the same situation happens again.
-
E3 : If e
vaporator sensor temperature is over 60℃(140℉).
-
E4 : The ice machine automactically drains 5 minutes after the bind is full. E4 will be
displayed if the water is not drained for 480 seconds.
-
E5 :
1) For the first ice making cycle: If the float switch does not sense enough water at
the end of the first water supply cycle, the ice machine will go back to the water
supply cycle again before advancing to the harvest cycle. E5 will be displayed If
the float switch continues to sense insufficient water levels during subsequent
supply cycles.
2) Beginning with the second ice making cycle: If the float switch does not sense
sufficient water levels at the end of the harvest cycle, the ice machine will return to
the harvest cycle instead of advancing to the freezing cycle. E5 will be displayed If
the float switch continues to sense insufficient water levels during the second
harvest cycle.
-
E6 : If the evaporator sensor is either damaged or disconnected.
-
E7 : If main PCB is not operating properly.
Содержание BLMI-300A
Страница 1: ...SERVICE MANUAL BLMI 300A BLMI 500A BLMI 650A BLMI 900A Ver200626 ...
Страница 35: ...4 Circuit diagrams and technical data 4 1 Circuit diagrams 4 1 1 BLMI 300A 115V 60Hz ...
Страница 36: ...4 1 2 BLMI 500A 115V 60Hz ...
Страница 37: ...4 1 3 BLMI 650A 208 230V 60Hz ...
Страница 38: ...4 1 4 BLMI 900A 208 230V 60Hz ...