![Blue-White FLEXFLO A1 Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/blue-white/flexflo-a1-series/flexflo-a1-series_operating-manual_2776990010.webp)
Pipe Tee
1/2” male NPT
1/4” male NPT
Weight,
Ceramic
Suction tubing, PVC
3/8" (0.95 cm) O.D. X
1/4” (0.64 cm) I.D.
Strainer,
Polypropylene
PVDF
Spring, Hastelloy C-276
Polypropylene
O-ring, TFE/P (optional EP)
Ball, Ceramic
O-ring, TFE/P (optional EP)
Polypropylene
Injection nose
may be trimmed
(removed) when
injecting into
small pipe.
Install upward
for best results.
5.3
Installing Injection Fitting and Strainer
Assemble the injection fitting and strainer per the figures below.
NOTE
: Install upward for best results.
NOTE
: The injection nose may be trimmed (removed) when injecting into a small pipe.
Proper eye and skin protection must be worn when installing and servicing the pump.
INJECTION FITTING AND STRAINER FOR 1/4” (0.64 CM) I.D. CONNECTION END MODELS
Discharge Injection Fitting / Check Valve
Suction Tubing and Strainer
CAUTION
!
5.4
Programming FVS (Flow Verification Sensor)
Directions
1
Confirm that pump is in the OFF position
2
Press and hold FVS button
3
Toggle up/down arrow until desired
trigger time is shown (seconds)
4
Press and hold FVS button to set
NOTE: Alarm Delay Time range 1-20 seconds
Page 10
®
FLEXFLO A1
3
1
2