CHEM-FEED  CFPS

10.0  WARRANTY
10.1  Limited Warranty

The pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required).  The 
pump will be repaired or replaced at our discretion.  The pump head and roller assembly are warranted against damage 
from a chemical attack when the proper Diaphragm Failure Detection(DFD) system instructions and maintenance proce-
dures are followed.

10.2  What is not Covered

>

    Pump diaphragm and rubber components - They are perishable and require periodic replacement

>

    Pump removal, or re-installation, and any related labor charge.

>

    Freight to the factory.

>

    Pumps that have been tampered with, or in pieces.

>

    Damage to the pump that results from misuse, carelessness (such as chemical spills) on the    

                 

 

 

     enclosure, abuse, lack of maintenance, or alteration that is out of Blue-White's control.

>

    Pumps damaged by faulty wiring, power surges, or acts of nature.

Blue-White does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out 
of the use of its products.  Failure must have occurred due to defect in material or workmanship and not as a result of 
operation of the product other than in normal operation as defined in the pump operation manual.

The warranty status is determined by the pump's serial label and the sales invoice or receipt.  The serial label must be on 
the pump and be legible.  The warranty status of the pump will be verified by Blue-White or a factory authorized service 
center.

10.3  Obtaining In-Warranty Repair

Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the pump to be repaired. It is 

recommended to include foot strainer and injection/check valve fitting since these devices may be clogged and part of the 
problem. Please enclose a brief description of the problem as well as the original invoice or sales receipt, or copy showing 
the date of purchase. Prepay all shipping costs. COD shipments will not be accepted. Warranty service must be 
performed by the factory or an authorized service center. Damage caused by improper packaging is the responsibility of 
the sender. When In-Warranty repair or replacement is completed, the factory pays for return shipping to the dealer or 
customer.

10.4  Product Use Warning

Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction 
manual includes a description of the associated product warranty and provides the user with important safety information. 
Purchasers, installers, and operators of Blue-White products should take the time to inform themselves about the safe 
operation of these products. In addition, Customers are expected to do their own due diligence regarding which products 
and materials are best suited for their intended applications. Blue-White is pleased to assist in this effort but does not 
guarantee the suitability of any particular product for any specific application as Blue-White does not have the same 
degree of familiarity with the application that the customer/end user has. While Blue-White will honor all of its product 
warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its defective 
parts or products in accordance with the associated product warranties.

 BLUE-WHITE SHALL NOT BE LIABLE EITHER 

IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR 
CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR 
OF THEIR NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.

10.5  Chemical Resistance Warning

Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well 
informed and aware of the precautions to be taken when injecting or measuring various chemicals, especially those 
considered to be irritants, contaminants or hazardous. Customers are expected to do their own due diligence regarding 
which products and materials are best suited for their applications, particularly as it may relate to the potential effects of 
certain chemicals on Blue-White products and the potential for adverse chemical interactions. 
Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was 
supplied to Blue-White by reputable sources, but Blue-White is not able to vouch for the accuracy or completeness thereof.  
While Blue-White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be 
obligated to repair or replace its defective parts or products in accordance with the associated product warranties.

 

BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER 
DIRECT,  INDIRECT,  INCIDENTAL,  OR  CONSEQUENTIAL,  ARISING  OUT  OF  OR  RELATED  TO  THE  USE  OF 
CHEMICALS IN CONNECTION WITH ANY BLUE-WHITE PRODUCTS.

®

11.0  Chem-Feed  Skid System Matrix

CHEM-FEED

®

 Engineered Plastic Skid System Model Number

CFPS-1

Single pump system - Single Pump - single chemical / single outlet, PE structure

CFPS-2

Duplex system - Dual Pump - single chemical / single outlet, PE structure

CFPS-3

Triplex pump system - Dual Pump - single chemical / single outlet, PE structure

Piping / Valves / Unions / Seal Materials

A

PVC piping, 1/2” OD PVC braided tubing connections

D

CPVC piping, 1/4” ID polyethylene tubing connections

B

CPVC piping, 1/2” OD PVC braided tubing connections

X

Skid frame only without piping

C

PVC piping, 1/4” ID polyethylene tubing connections

Seal Material

V

FKM

E

EPDFM

Calibration Cylinder 

A

PVC

Glass

A

64 GPH (4000 ml)

A

B

32 GPH (2000 ml)

B

C

16 GPH (1000 ml)

C

P

D

8 GPH (500 ml)

D

Q

E

4 GPH (250 ml)

E

R

F

1.6 GPH (100 ml)

F

S

X

None

Pulsation Dampener

A

10 cubic inch, CPVC body, PTFE diaphragm

X

None

Pressure Guage w/Guard

A

200 PSI gauge with guard, PTFE diaphragm

C

30 PSI gauge with guard, PTFE diaphragm

B

100 PSI gauge with guard, PTFE diaphragm

X

None

Flow Meter and Strainer

G

Model MS612 chemical feed flow meter, 10-5,000 ml/min (0.158 - 79.2 GPH)

H

Model MS622 chemical feed flow meter, 100-10,000 ml/min (1.58 - 158 GPH)

X

Inlet strainer only

Miscellaneous Options

 

(leave blank if not specified)

1

Install and ship with a specific pump model

2

Perform pressure and fluid testing with a specific pump model

3

Perform pressure, fluid testing, and ship with pump model installed

5

1/2” Intake manifold plumbing (Dual Skid Only)

A

Isolation ball shut-off valves at check valves

T1

PTFE Tubing for Single Skid

T2

PTFE Tubing for Dual Skid

T3

PTFE tubing for Triplex Skid

C1

Terminal box and electrical outlet box for Single Skid

C2

Terminal box and electrical outlet box Duplex Skid

C3

Terminal box and electrical outlet box Triplex Skid

CFPS-1

A

V

-

A

A

A

G

1

Sample Model Number

 

®

CHEM-FEED  CFPS

Содержание CHEM-FEED CFPS Series

Страница 1: ...Municipal Skid Systems Series CFPS CHEM FEED ...

Страница 2: ... and Typical Operation Single Skid 10 7 1 How to Operate the Chem Feed Skid System Single Skid 11 8 0 Component Identification and Typical Operation Duplex Skid 12 8 1 How to operate the Chem Feed Skid System Duplex Skid 13 9 0 Component Identification and Typical Operation Triplex Skid 14 9 1 How to operate the Chem Feed Skid System Triplex Skid 15 10 0 Chem Feed Skid System Matrix 19 11 0 Warran...

Страница 3: ...READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE 1 714 893 8529 sales blue white com customerservice blue white com 5300 Business Drive Huntington Beach CA 92649 Page 3 CHEM FEED CFPS ...

Страница 4: ...rd components Pressure Relief Valve Protects the system from over pressurization 5 150 psi setting range 150 psi maximum system pressure Ships on all systems Check Valve Protects the user from back flow during pump maintenance Ships on all systems Flow Verification Sensor MS6 accurately verifies chemical feed Exclusive to Blue White Inlet Y Strainer Protects system components from damage cause by ...

Страница 5: ...C end caps 1 2 PVC pipe outlet vent Available volumes 1 6 GPH 100ml 4 GPH 250ml 8 GPH 500ml 16 GPH 1000ml 32 GPH 2000ml and 64 GPH 4000mL Pulsation Dampener PD CPVC body 10 cubic inch volume Gauge W Guard G Gauge liquid filled stainless steel with blowout plug bottom mount 1 4 NPT theads Available pressure ranges 0 30 psi 0 100 psi 0 200 psi Guard PVC body temperature compensated oil filled Check ...

Страница 6: ...ned differently from drawings below However the dimensions shown below remain the same no matter your configuration Dual Pump System 30 00in 76 20cm 34 00in 86 36cm 45 37in 115 24cm 118 04cm 46 47in 32 15in 81 65cm 35 00in 88 90cm 49 50in 125 73cm Page 6 CHEM FEED CFPS ...

Страница 7: ...Triple Pump System 44 85in 113 92cm 48 57in 123 37cm 72 00in 182 88cm 76 00in 193 04cm B C 49 50in 125 73cm 32 91in 83 59cm 35 00in 88 90cm Page 7 CHEM FEED CFPS ...

Страница 8: ... 5 0 Mounting Pump to the Chem Feed System Single and Dual System Socket Head Screw SS 10 32 625 10 washer and 10 32 nut Qty 4 of each per pump Mounting Bracket Qty 2 per pump Page 8 CHEM FEED CFPS ...

Страница 9: ...e mounting brackets WALL MOUNT Remove the mounting brackets using a 1 4 wrench or socket Install those same mounting brackets in the vertical position on the sides of the skid system Mount the skid system to the wall using eight 1 4 20 Bolts see fig 2 through the mounting brackets 6 0 Mounting the Chem Feed System Single and Dual System fig 1 fig 2 Page 9 CHEM FEED CFPS ...

Страница 10: ...ure Relief Valve preset at 50psi Chemical Output Pressure Gauge Chemical Feed Flowmeter One way Check Valve with union Calibration Cylinder Pulse Dampener optional V2 Chemical Input 2 Chemical Input 1 V1 V10 V7 V8 V6 Y Strainer PRV V3 V4 V5 V9 Gauge Guard Page 10 CHEM FEED CFPS ...

Страница 11: ...cylinder is filled Close ball valves V 1 V 2 and V 6 Open ball valve V 5 and V 10 to inject chemical solution into your system Note the chemical solution level in the calibration cylinder To calibrate pump at maximum speed into your system Press the prime button on pump The prime mode runs the pump at maximum speed for 60 seconds 1 minute on all Blue White ProSeries M pumps To calibrate pump at yo...

Страница 12: ...way Check Valves with union Y Strainer PRV V11 PRV Pressure Relief Valve preset at 50psi V1 V2 V12 V7 V9 Chemical Output Chemical Input 1 Chemical Input 2 Chemical Feed Flowmeter Calibration Cylinder V8 Pressure Gauge Pulsation Dampener optional Y Strainer V10 Page 12 CHEM FEED CFPS ...

Страница 13: ...der is filled to top calibration line Do not leave pump unattended during this operation Stop pump once calibration cylinder is filled Close ball valves V 1 V 2 and V 7 Open ball valve V 4 or V 5 depending on which pump you re calibrating Open ball valve V 6 and V 12 to inject chemical solution into your system Note the chemical solution level in the calibration cylinder To calibrate pump at maxim...

Страница 14: ...tional Electrical Outlet Box optional Chemical Output 1 Chemical Output 2 Chemical Input 2 Chemical Input 1 Chemical Feed Flowmeter Calibration Cylinder Pressure Gauge Pulsation Dampener optional Y Strainer P 1 P 2 P 3 V 3 V 11 V 15 V 18 V 8 V 9 V 19 V 7 V 20 V 16 V 4 V 5 V 10 V 21 V 14 V 6 V 13 V 22 V 17 V 12 Page 14 CHEM FEED CFPS ...

Страница 15: ... pump speed before running this routine Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions To calibrate pump 2 Open ball valve V 1 or V 2 depending on your inlet side Open ball valve V 11 and V 12 Close ball valves V 5 V 7 V 10 V 13 V 17 V 20 and V 21 Open ball valve V 6 or V 14 Close the ball valve that was not chosen to be open Open b...

Страница 16: ...p once calibration cylinder is filled Close ball valves V 1 V 2 and V 14 Open ball valve V 17 and V 21 Note chemical solution level in the calibration cylinder To calibrate pump at maximum speed into your system Press the prime button on pump P 3 The prime mode runs the pump at maximum speed for 60 seconds 1 minute on all Blue White ProSeries pumps To calibrate pump at your desired feed rate you m...

Страница 17: ...S 3 U 4 V 11 T 3 P U 5 U 6 U 7 Safety vent to tank CC 1 T 4 V 4 V 5 G 1 V 8 V 7 MS 6 1 Chemical Outlet 1 V 10 U 4 F 1 S 2 V 9 PD 1 CV 2 V 12 V 17 V 16 V 13 Chemical Inlet 1 Chemical Inlet 2 V 6 V 14 G 2 V 18 V 20 MS 6 2 Chemical Outlet 1 V 21 U 10 F 2 S 5 V 19 PD 2 V 22 Page 17 CHEM FEED CFPS ...

Страница 18: ...ards in the industry Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information Purchasers installers and operators of Blue White products should take the time to inform themselves about the safe operation of these products In addition Customers are expected to do their own due diligence regarding which products...

Страница 19: ...ubic inch CPVC body PTFE diaphragm X None Pressure Guage w Guard A 200 PSI gauge with guard PTFE diaphragm C 30 PSI gauge with guard PTFE diaphragm B 100 PSI gauge with guard PTFE diaphragm X None Flow Meter and Strainer G Model MS612 chemical feed flow meter 10 5 000 ml min 0 158 79 2 GPH H Model MS622 chemical feed flow meter 100 10 000 ml min 1 58 158 GPH X Inlet strainer only Miscellaneous Opt...

Страница 20: ... waste but use the collection framework available to them for the return recycle recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances The WEEE marking applies only to countries within the European Union EU and Norway Appliances are labeled in accordance with European Directive 2002 96 EC Contact your local waste ...

Отзывы: