CHEM-FEED CD1

READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE.

CHEM-FEED CD1

+1 (714) 893 - 8529

[email protected]

[email protected]

5300 Business Drive
Huntington Beach, CA 92649

1.0

Introduction

4

1.1 Available Models

4

2.0

Engineering Specifications

4

3.0

Construction Materials

5

3.1 Wetted Components

5

3.2 Non-Wetted Components

5

4.0

What’s In The Box

6

4.1 Agency Listings

6

5.0

Installation

7

5.1 Mounting Location

7

5.2 Wall Mounting

8

5.3 Programming 4-20mA Input (V option only)

9

5.4 Programming FVS (Flow Verification Sensor)

10

6.0

Power Connections

10

7.0

Touchpad Layout

11

7.1 IO Connection

12

8.0

Output Adjustment

14

9.0

Diaphragm Failure Detection (DFD)

14

10.0

Pump Maintenance

15

10.1 Routine Inspection and Maintenance

15

10.2 Cleaning Pump

15

10.3 Replacing the Pump Diaphragm

15

11.0

Accessories

16

12.0

Replacement Parts List

18

12.1 Exploded View

19

13.0

Troubleshooting

20

14.0

Warranty

21

APPENDIX A

Acronyms

22

APPENDIX B

Model Number Matrix

23

Содержание CHEM-FEED CD1 Series

Страница 1: ...Multi Diaphragm Metering Pump Series CD1 CHEM FEED...

Страница 2: ...Input V option only 9 5 4 Programming FVS Flow Verification Sensor 10 6 0 Power Connections 10 7 0 Touchpad Layout 11 7 1 IO Connection 12 8 0 Output Adjustment 14 9 0 Diaphragm Failure Detection DFD...

Страница 3: ...Page 3 CHEM FEED CD1 READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE 1 714 893 8529 sales blue white com customerservice blue white com 5300 Business Drive Huntington Beach CA 92649...

Страница 4: ...0 centipoise Maximum Suction Lift 20 ft at 0 PSI Ambient Operating Temperature O O O O 14 F to 115 F 10 C to 42 C Ambient Storage Temperature O O O O 40 F to 158 F 40 C to 70 C Operating Voltage 115V6...

Страница 5: ...optional EP Ancillary Items Provided Suction Tubing 3 8 OD x 1 4 ID x 5 Clear PVC Discharge Tubing 3 8 OD x 1 4 ID x 5 Polyethylene LDPE Suction Strainer Polypropylene Weight Ceramic Enclosure Valox P...

Страница 6: ...y Directive 2006 42 EC BS EN 60204 1 Low Voltage Directive 2014 35 EU BS EN 61010 1 EMC Directive 2014 30 EU BS EN 50081 1 BS EN 50082 1 Symbol Description Warning Risk of electric shock Caution Refer...

Страница 7: ...n check valve at the discharge side of the pump to prevent the system fluid from flowing back through pump during tube replacement or during tube rupture NOTE It is recommended to have a pressure reli...

Страница 8: ...ly serviced 10 Self Tap 2 X 4 50 in 11 43 cm Wall Mount Bracket Side View Mounted Pump Front View 2 Lower the pump so that the tab on the wall mount is inserted into the slot located on the back of th...

Страница 9: ...lluminate Use arrow keys to toggle min mA value for the pump to operate at 4 Press 4 20mA Input button for MIN Speed light to illuminate 5 Use arrow keys to toggle MIN Speed value for the pump to oper...

Страница 10: ...properly grounded grounding type receptacle Use the voltage for which the power cord is rated Do not strap together control input output cables and power cables When there is a power interruption the...

Страница 11: ...LED LCD Readout 2 Rate Display Key 3 Flow Verification Sensor FVS Key 4 Remote Start Stop Key 5 Lock Out Key 6 Prime Key 7 Start Stop Key 8 Down Key 9 Up Key 10 Manual Speed Adjust 11 4 20mA 3 3 4 4...

Страница 12: ...12 CHEM FEED CD1 Pump Right Side Panel Item Number Item 1 M12 Input Connector 1 2 M12 Input Connector 2 Included with CD1V ONLY 3 M12 Output Connector 4 USB C Connector 1 3 2 M12 connectors not includ...

Страница 13: ...Stop N O Dry Contact Closure Open Stop Gnd Run P2 Ground DC Ground 0 VDC P3 FVS 15 VDC 60 mA To power FVS sensor P4 FVS DC Ground 0 VDC FVS Ground Input P5 FVS Signal Input Signal Input for FVS Signal...

Страница 14: ...c Acid Sodium Hydroxide and many others System will not be triggered by water rain condensation etc or lubricants If system has detected chemical pump diaphragm must be replaced and pump head must be...

Страница 15: ...ume responsibility for damage to pump that has been caused by chemical attack 10 2 Cleaning Pump Pump will require occasional cleaning especially Injection fitting Footvalve Strainer and pump head val...

Страница 16: ...T CQE Kit contains One discharge fitting red and One suction fitting white Both fittings come with EP o rings installed KIT CQA Kit contains Kit contains One discharge fitting red and One suction fitt...

Страница 17: ...e One 3 8 discharge tube One foot valve and strainer and One mounting bracket with screws KIT S15 Kit contains One 15 gallon tank One 3 8 suction tube One 3 8 discharge tube One foot valve and straine...

Страница 18: ...0 131 CAM C 1500 S A 125 COMPLETE 1 10 90011 261 SCREW 5 16 18 X 50 L PHIL NYLON BLK 1 11 76002 034 CAP DFD 1 12 76001 966 STANDOFF HEX MALE FEMALE THREADED MACH 2 13 71010 745 COVER PUMPHEAD MOUNT AS...

Страница 19: ...12 1 EXPLODED VIEW Page 19 CHEM FEED CD1 17...

Страница 20: ...t temperature E05 Inverter Error Contact Blue White Industries 714 893 8529 techsupport blue white com E06 No Motor Connection Contact Blue White Industries 714 893 8529 techsupport blue white com E08...

Страница 21: ...e enclose a brief description of the problem and proof of purchase Prepay all shipping and insurance cost COD shipments will not be accepted Damage caused by improper packaging is the responsibility o...

Страница 22: ...ity polyethylene LPH Liters per hour mA Milliampere min Minute mL Milliliters MSDS Material Safety Data Sheet N C Normally Close N O Normally Open NPT National Pipe Thread NSF National Sanitation Foun...

Страница 23: ...Page 23 CHEM FEED CD1...

Страница 24: ...ive must not dispose of end of life EEE as unsorted municipal waste but use the collection framework available to them for the return recycle recovery of WEEE and minimize any potential effects of EEE...

Отзывы: