Blue-White CHEM-FEED CD1 Series Скачать руководство пользователя страница 21

Error Code

Explanation

Troubleshooting

E01

Motor Over Current

Ensure that diaphragm is installed properly

E02

Over Voltage

Check power supply output voltage

E03

Under Voltage

Check power supply output voltage

E04

Temperature exceeds 75°C at control

Check ambient conditions, restart pump once cooled 
to ambient temperature

E05

Inverter Error

Contact Blue-White Industries (714) 893-8529
[email protected]

E06

No Motor Connection

Contact Blue-White Industries (714) 893-8529
[email protected]

E08

Motor Stall

Ensure that diaphragm is installed properly

E10

Capacitor bank charging error

Contact Blue-White Industries (714) 893-8529
[email protected]

E17

Communication error at display

Contact Blue-White Industries (714) 893-8529 
[email protected]

13.0  TROUBLESHOOTING

Page 20

CHEM-FEED CD1

Page 21

CHEM-FEED CD1

14.0  WARRANTY
14.1  Limited Warranty

Your Blue-White product is a quality product and is warranted for a specific time from date of purchase (proof of purchase is required). 
The product will be repaired or replaced at our discretion. Failure must have occurred due to defect in material or workmanship and not 
as a result of operation of the product other than in normal operation as defined in the product manual. Warranty status is determined 
by the product's serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status of 
the product will be verified by Blue-White or a factory authorized service center. 
CHEM-FEED® CD1 pumps are warranted for 2 years from date of purchase (proof of purchase is required). Pumps will be repaired or 
replaced at our discretion. 

14.2  DIAFLEX  Warranty

®

DIAFLEX® diaphragms are warranted for the life of the pump. Blue-White will replace a damaged diaphragm at no cost to the customer 
provided the pump was at all times operated within the guidelines included in the pump's operation manual. This warranty only applies 
to DIAFLEX® diaphragms, not the pumps themselves. Blue-White pumps are separately covered by warranties specific to them.

14.3  What is not Covered

>

    Flex-A-Prene diaphragm and rubber components - They are perishable and require periodic replacement

>

    Pump removal, or re-installation, and any related labor charge.

>

    Freight to the factory, or service center

>

    Pumps that have been tampered with, or in pieces.

>

    Damage to the pump that results from misuse, carelessness (such as chemical spills on the  

 

                

   

 

 enclosure), abuse, lack of maintenance, or alteration that is out of Blue-White control.

>

    Pumps damaged by faulty wiring, power surges, or acts of nature.

Blue-White does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of the use of 
its products.  Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other 
than in normal operation as defined in the pump operation manual.

The warranty status is determined by the pump's serial label and the sales invoice or receipt.  The serial label must be on the pump and 
be legible.  The warranty status of the pump will be verified by Blue-White or a factory authorized service center.

14.4  Procedure for In-Warranty Repair

Warranty service must be performed by the factory or an authorized service center. Contact the factory or local repair center to obtain a 

RMA (Return Material Authorization) number. It is recommended to include foot strainer and injection/check valve fitting since these 
devices may be clogged and part of the problem. Decontaminate, dry, and carefully pack the product to be repaired. Please enclose a 
brief description of the problem and proof of purchase. Prepay all shipping and insurance cost. COD shipments will not be accepted. 
Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair is completed, the factory pays for 
return shipping to the dealer or customer.

14.5  Product Use Warning

Blue-White products are manufactured to meet the highest quality standards in the industry. Each product instruction manual includes a 
description of the associated product warranty and provides the user with important safety information. Purchasers, installers, and 
operators of Blue-White products should take the time to inform themselves about the safe operation of these products. In addition, 
Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended 
applications. Blue-White is pleased to assist in this effort but does not guarantee the suitability of any particular product for any specific 
application as Blue-White does not have the same degree of familiarity with the application that the customer/end user has. While Blue-
White will honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or 
replace its defective parts or products in accordance with the associated product warranties.

 BLUE-WHITE SHALL NOT BE LIABLE 

EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE WHETHER DIRECT, INDIRECT, INCIDENTAL, OR 
CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR 
NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.

14.6  Chemical Resistance Warning

Blue-White offers a wide variety of wetted parts. Purchasers, installers, and operators of Blue-White products must be well informed 
and aware of the precautions to be taken when injecting or measuring various chemicals, especially those considered to be irritants, 
contaminants or hazardous. Customers are expected to do their own due diligence regarding which products and materials are best 
suited for their applications, particularly as it may relate to the potential effects of certain chemicals on Blue-White products and the 
potential for adverse chemical interactions. 

Blue-White tests its products with water only. The chemical resistance information included in this instruction manual was supplied to 
Blue-White by reputable sources, but Blue-White is not able to vouch for the accuracy or completeness thereof.  While Blue-White will 
honor all of its product warranties according to their terms and conditions, Blue-White shall only be obligated to repair or replace its 
defective parts or products in accordance with the associated product warranties.

 

BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE, WHETHER DIRECT, 
INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN 
CONNECTION WITH ANY BLUE-WHITE PRODUCTS.

Содержание CHEM-FEED CD1 Series

Страница 1: ...Multi Diaphragm Metering Pump Series CD1 CHEM FEED...

Страница 2: ...Input V option only 9 5 4 Programming FVS Flow Verification Sensor 10 6 0 Power Connections 10 7 0 Touchpad Layout 11 7 1 IO Connection 12 8 0 Output Adjustment 14 9 0 Diaphragm Failure Detection DFD...

Страница 3: ...Page 3 CHEM FEED CD1 READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE 1 714 893 8529 sales blue white com customerservice blue white com 5300 Business Drive Huntington Beach CA 92649...

Страница 4: ...0 centipoise Maximum Suction Lift 20 ft at 0 PSI Ambient Operating Temperature O O O O 14 F to 115 F 10 C to 42 C Ambient Storage Temperature O O O O 40 F to 158 F 40 C to 70 C Operating Voltage 115V6...

Страница 5: ...optional EP Ancillary Items Provided Suction Tubing 3 8 OD x 1 4 ID x 5 Clear PVC Discharge Tubing 3 8 OD x 1 4 ID x 5 Polyethylene LDPE Suction Strainer Polypropylene Weight Ceramic Enclosure Valox P...

Страница 6: ...y Directive 2006 42 EC BS EN 60204 1 Low Voltage Directive 2014 35 EU BS EN 61010 1 EMC Directive 2014 30 EU BS EN 50081 1 BS EN 50082 1 Symbol Description Warning Risk of electric shock Caution Refer...

Страница 7: ...n check valve at the discharge side of the pump to prevent the system fluid from flowing back through pump during tube replacement or during tube rupture NOTE It is recommended to have a pressure reli...

Страница 8: ...ly serviced 10 Self Tap 2 X 4 50 in 11 43 cm Wall Mount Bracket Side View Mounted Pump Front View 2 Lower the pump so that the tab on the wall mount is inserted into the slot located on the back of th...

Страница 9: ...lluminate Use arrow keys to toggle min mA value for the pump to operate at 4 Press 4 20mA Input button for MIN Speed light to illuminate 5 Use arrow keys to toggle MIN Speed value for the pump to oper...

Страница 10: ...properly grounded grounding type receptacle Use the voltage for which the power cord is rated Do not strap together control input output cables and power cables When there is a power interruption the...

Страница 11: ...LED LCD Readout 2 Rate Display Key 3 Flow Verification Sensor FVS Key 4 Remote Start Stop Key 5 Lock Out Key 6 Prime Key 7 Start Stop Key 8 Down Key 9 Up Key 10 Manual Speed Adjust 11 4 20mA 3 3 4 4...

Страница 12: ...12 CHEM FEED CD1 Pump Right Side Panel Item Number Item 1 M12 Input Connector 1 2 M12 Input Connector 2 Included with CD1V ONLY 3 M12 Output Connector 4 USB C Connector 1 3 2 M12 connectors not includ...

Страница 13: ...Stop N O Dry Contact Closure Open Stop Gnd Run P2 Ground DC Ground 0 VDC P3 FVS 15 VDC 60 mA To power FVS sensor P4 FVS DC Ground 0 VDC FVS Ground Input P5 FVS Signal Input Signal Input for FVS Signal...

Страница 14: ...c Acid Sodium Hydroxide and many others System will not be triggered by water rain condensation etc or lubricants If system has detected chemical pump diaphragm must be replaced and pump head must be...

Страница 15: ...ume responsibility for damage to pump that has been caused by chemical attack 10 2 Cleaning Pump Pump will require occasional cleaning especially Injection fitting Footvalve Strainer and pump head val...

Страница 16: ...T CQE Kit contains One discharge fitting red and One suction fitting white Both fittings come with EP o rings installed KIT CQA Kit contains Kit contains One discharge fitting red and One suction fitt...

Страница 17: ...e One 3 8 discharge tube One foot valve and strainer and One mounting bracket with screws KIT S15 Kit contains One 15 gallon tank One 3 8 suction tube One 3 8 discharge tube One foot valve and straine...

Страница 18: ...0 131 CAM C 1500 S A 125 COMPLETE 1 10 90011 261 SCREW 5 16 18 X 50 L PHIL NYLON BLK 1 11 76002 034 CAP DFD 1 12 76001 966 STANDOFF HEX MALE FEMALE THREADED MACH 2 13 71010 745 COVER PUMPHEAD MOUNT AS...

Страница 19: ...12 1 EXPLODED VIEW Page 19 CHEM FEED CD1 17...

Страница 20: ...t temperature E05 Inverter Error Contact Blue White Industries 714 893 8529 techsupport blue white com E06 No Motor Connection Contact Blue White Industries 714 893 8529 techsupport blue white com E08...

Страница 21: ...e enclose a brief description of the problem and proof of purchase Prepay all shipping and insurance cost COD shipments will not be accepted Damage caused by improper packaging is the responsibility o...

Страница 22: ...ity polyethylene LPH Liters per hour mA Milliampere min Minute mL Milliliters MSDS Material Safety Data Sheet N C Normally Close N O Normally Open NPT National Pipe Thread NSF National Sanitation Foun...

Страница 23: ...Page 23 CHEM FEED CD1...

Страница 24: ...ive must not dispose of end of life EEE as unsorted municipal waste but use the collection framework available to them for the return recycle recovery of WEEE and minimize any potential effects of EEE...

Отзывы: