LIMITED WARRANTY

®

Your new FlexFlo  pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required).  The 
pump will be repaired or replaced at our discretion. Pump Head and roller assembly is warrantied against damage from chemical attack 
when proper Tube Failure Detection (TFD) system instructions and maintenance procedures are followed.
 
 

 

 

 

 

 

 

WHAT IS NOT COVERED

• 

Pump Tube Assemblies and rubber components – They are perishable and require periodic replacement.

• 

Pump removal, or re-installation, and any related labor charge.

• 

Freight to the factory, or ProSeries service center.

• 

Pumps that have been tampered with, or in pieces.

• 

Damage to the pump that results from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of 
maintenance, or alteration which is out of our control.

• 

Pumps damaged by faulty wiring, power surges or acts of nature.

Blue-White Industries, Ltd. does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising 
out of the use of its products. Failure must have occurred due to defect in material or workmanship and not as a result of operation of 
the product other than in normal operation as defined in the pump manual.

Warranty status is determined by the pump's serial label and the sales invoice or receipt. The serial label must be on the pump and 
legible. The warranty status of the pump will be verified by Blue-White Industries, Ltd. or a factory authorized service center.

OTHER IMPORTANT WARRANTY INFORMATION

Be advised that injection and metering devices are not intended as a means of treating water to render it suitable for human 
consumption. When used as hypochlorinators, they are meant to destroy bacteria and algae contamination, before its removal by 
filtration. Acid and soda injectors are used for PH control (balance). Blue-White Industries. Ltd. injectors are factory tested with water 
only for pressure and performance. Installers and operators of these devices must be well informed and aware of the precautions to be 
taken when injecting various chemicals, especially those considered hazardous or dangerous, eye protection must be worn when 
working around this product or any other metering type of pump.

Should it become necessary to return the pump for repair or service, you must attach information regarding the chemical used as some 
residue may be present within the unit which could be a hazard to service personnel.

Blue-White Industries, Ltd. will not be liable for any damage that may result by the use of chemicals with their injectors and its 
components. 

PROCEDURE FOR IN-WARRANTY REPAIR

Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the pump to be repaired. It is recommended 
to include the foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem.  Enclose a brief 
description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase. Prepay all shipping 
costs.  

COD shipments will not be accepted

. Warranty service must be performed by the factory or an authorized service center.  

Damage caused by improper packaging is the responsibility of the sender.  When in-warranty repair or replacement is completed, the 
factory pays for return shipping to the dealer or customer.

Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not 
dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, 
recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the 
presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. 
Appliances are labeled in accordance with European Directive 2002/96/EC. 

Contact your local waste recovery agency for a 

Designated Collection Facility

 in your area.

P.N. 80000-588

5300 Business Drive, Huntington Beach, CA 92649, USA

Phone:

 714-893-8529     

FAX:

 714-894-9492

E mail:

 [email protected]  

or

  [email protected]    

URL:

 www.Blue-White.com

Rev. 10  20200213

Blue-White

Industries, Ltd.

R

Содержание FLEXFLO A2P Series

Страница 1: ...l sales blue white com techsupport blue white com URL www Blue White com SERIES A2P Operating Manual system TFD Tube Failure Detection Exclusive 2 TWO YEAR WARRANTY ProSeries Protected by Patents 8 41...

Страница 2: ...sions 6 4 3 Installing Injection Fitting and Strainer 7 5 0 Power Connections 8 5 1 Wiring Terminal and I O Schematics 9 6 0 How to Adjust the Output 10 7 0 Tube Failure Detection TFD 10 8 0 Alarm Rel...

Страница 3: ...metering pump 4 1 2 inches 11 43 cm off the ground or surface n Made out of tough Stainless Steel n Provides a stable mounting surface Stainless steel extended brackets allow the pump to be securely m...

Страница 4: ...BT Rollers PVDF Roller Bearings SS Ball Bearings Motor Shaft Chrome plated steel TFD System Sensor Pins Hastelloy C 276 Power Cord 3 conductor SJTW A water resistant Tube Installation Tool GF nylon Mo...

Страница 5: ...4X Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with enclosed equipment to provide a degree of protection against falling dir...

Страница 6: ...rge line becomes blocked NOTE The does not require back pressure Keep the discharge pressure as FlexFlo peristaltic metering pump low as possible to maximize the tube life 4 2 Dimensions All diagrams...

Страница 7: ...T Discharge Injection Fitting Check Valve Suction Tubing and Strainer Weight Ceramic Suction Tubing PVC 3 8 95 cm OD X 1 4 64 cm ID Strainer Polypropylene PVDF Spring Hastelloy C 276 PVDF O Ring TFE P...

Страница 8: ...uto restart feature which will restore pump to operating state it was in when power was lost NOTE When in doubt regarding your electrical installation contact a licensed electrician Electrical connect...

Страница 9: ...OT FUSE F1 N A 5 AMP 5A SLOW BLOW 20 X 5MM INPUT FVS SYSTEM FLOW VERIFICATION SENSOR FV SENSOR ONLY INPUT REMOTE START STOP DRY CONTACT C NORM CLOSED NORM OPEN COMMON Shielded cables should be used on...

Страница 10: ...mical Detection To determine if the chemical used will be detected by the system remove the pump head cover and the pump tube and roller assembly Place a small amount of chemical in the bottom of the...

Страница 11: ...ll cause the solution to squirt when disconnecting the tube connections Disconnect the system plumbing from the pump tube adapters Step 2 Place the switch in the OFF position Using the provided tool r...

Страница 12: ...on the rotor must face forward front of the pump FlexFlo Ensure the pump is stopped With the pump stopped press the suction side of tube adapter securely into the pump head Clip tube installation tool...

Страница 13: ...als 4 After servicing operate the pump to verify normal operation NOTE The manufacturer does not assume responsibility for damage to a pump that has been caused by a chemical attack How to Clean and L...

Страница 14: ...THIS PAGE IS INTENTIONALLY LEFT BLANK Page 14 FlexFlo...

Страница 15: ...Ibs 4 required per pump sold individually A2 SXX C 90011 237 1 1 2 Roller Assembly Complete Rotor For NEE and NGG Tubes A2 SNGG R 1 Tubing in this group are interchangeable with single roller assembl...

Страница 16: ...informed and aware of the precautions to be taken when injecting various chemicals especially those considered hazardous or dangerous eye protection must be worn when working around this product or a...

Отзывы: