Page 11
M12 Connector
PIN
Function
Specifications
Reference
P1
4-20mA Input (+)
120 Ohm Impedance, Non
powered loop
(+) Positive
P2
4-20mA Input (-)
120 Ohm Impedance, Non
powered loop
(-) Negative
P3
Not Used
P4
Not Used
P5
Not Used
P4
P1
P2
P3
P5
PIN
Function
Specifications
Reference
P1
Remote Start / Stop
N.O. Dry Contact Closure
Open = Stop
Gnd = Run
P2
Ground
DC Ground
0 VDC
P3
FVS (+)
15 VDC @ 60 mA
To power FVS sensor
P4
FVS (-)
DC Ground (0 VDC)
FVS Ground Input
P5
FVS (Signal)
Input Signal
Input for FVS Signal
M12 Input Connector 1
M12 Input Connector 2
PIN
Function
Specifications
P1
Remote Start / Stop
N.O. Dry Contact Closure
P2
Ground
DC Ground
P3
FVS (+)
15 VDC @ 60 mA
P4
FVS (-)
DC Ground (0 VDC)
P5
FVS (Signal)
Input Signal
M12 Output Connector
®
CHEM-FEED MD1