minutes to detect the spa temperature and then to heat to
the set temperature if needed, depending upon mode.
When the low speed turns on automatically, it cannot be
deactivated from the panel; however, the high speed may be
started.
Blower
(optional)
This button is used to turn the blower on and off. If left on,
the blower automatically turns off after 15 minutes.
Jets 2
(optional)
If your system has a pump 2 installed instead of a blower, it
behaves exactly like a blower would.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is
energized. The second filter cycle begins 12 hours later.
Filter duration is programmable for 2, 4, 6, 8 hours or for
continuous filtration (indicated by “
”). The default
filter time is 2 hours. To program, press “Temp” or “Set,” then
“Jets.” Press “Temp” or “Set” to adjust. Press “Jets” to exit
programming.
The blower purges for 30 seconds at the beginning of each
filter cycle. The low speed of the pump runs during filtration
and the ozone generator (if installed) will be enabled.
Light
Press the “Light” button to turn the light on and off. If left on,
the light automatically turns off after 4 hours.
Mode
Mode is changed by pressing the “Temp” or “Set” button, then
pressing the “Light” button.
Standard Mode
is programmed to maintain the
desired temperature. Note that the last measured spa
temperature displayed is current only when the pump has
been running for at least 2 minutes. “
”
will
be
displayed momentarily when you switch into Standard Mode.
Economy Mode
heats the spa to the set temperature
only during filter cycles. “
” will display solid when
temperature is not current, and will alternate with
temperature when temperature is current.
Sleep Mode
heats the spa to within 20°F/10°C of the
set temperature only during filter cycles. “ ”will display solid
when temperature is not current, and will alternate with
temperature when temperature is current.
Freeze Protection
If the temperature sensors detect a drop to below
44°F/6.7°C within the heater, the pump and blower will
automatically activate to provide freeze protection. The
equipment stays on until 4 minutes after the sensors detect
that the spa temperature has risen to 45°F/7.2°C or higher.
In colder climates, an optional additional freeze sensor may
be added to protect against freeze conditions that may not be
sensed by the standard sensors. Aux freeze sensor
protection acts similarly except with the temperature
thresholds determined by the switch and without a 4-minute
delay in turnoff. See your dealer for details
.