2
Installation
8
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Griddles
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Assembly
NOTE:
•
All Models are delivered completely assembled. No further assembly is required.
•
This appliance is fitted with adjustable feet to enable the appliance to be positioned
securely and level. This should be carried out on completion of the gas connection. Refer
to the ‘Gas Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
•
Rear Roller Kit. For installation details, refer to the instructions supplied with each kit.
•
Plinth Kit. For installation details, refer to the instructions supplied with each kit.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
Blue Seal Gas Griddles do not require an electrical connection, as they function totally on the gas
supply only.
2.
It is essential that the gas supply is correct for the appliance to be installed and that adequate
supply pressure and volume is available. The following checks should therefore be made before
installation:-
a. Gas Type the appliance has been supplied for is
shown on coloured stickers located above the gas
connection and next to the rating plate. Check that
this is correct for the gas supply the appliance is be-
ing installed for. The gas conversion procedure is
detailed in this manual.
b. Supply Pressure required for this appliance is
shown in the “Specifications” section of this manual.
Check the gas supply to ensure adequate supply
pressure exists.
c. Input Rate of this appliance is stated on the Rating
Plate, refer to the ‘Dimensions’ section for rating plate
locations for the different models. The input rate
should be checked against the available gas supply
line capacity. Particular note should be taken if
the appliance is being added to an existing
installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
3.
Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG and is already converted ex-factory to the gas type labelled beside the gas
connection point. The regulator outlet pressure is fixed ex-factory and it is NOT to be
adjusted.
Combustible Surface Non Combustible Surface
Left/Right Hand Side
50 mm
0 mm
Rear
50 mm
0 mm
Rating Plate Location
for Leg Stand Models
Fig 1