6
Specifications
Electrical Supply Requirements
Electrical Connection
Electrical supply connection point is located at rear of appliance, approximately 74mm from right
hand side, 501mm from rear and 150mm from floor.
When connecting this electric appliance to mains supply, ensure following is carried out:-
An isolating switch is fitted within 2m of appliance, but not on appliance and in such a position
that user does not have to reach across cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS/NZS 3191 part
2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type.
Branch supply line shall be individually overload protected to correct current rating and supply
chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around wiring entry hole into appliance.
All wiring connections must be tight.
Refer to appropriate wiring standards for size of cable that is to be supplied to an appliance for
current drawn on that line.
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Warning
MODEL
1-Phase Connection
1P+N+E, 230-240V
3-Phase Connection
3P+N+E, 400-415V
GE570
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE576
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
Содержание GE570
Страница 9: ...7 Dimensions Dimensions GE570 GE576 ...
Страница 20: ...18 Wiring Schematic Static Oven Schematic GE570 ...
Страница 21: ...19 Wiring Schematic Static Oven Wiring Diagram GE570 ...
Страница 22: ...20 Wiring Schematic Convection Oven Schematic GE576 ...
Страница 23: ...21 Wiring Schematic Convection Oven Wiring Diagram GE576 ...
Страница 32: ......