11
Installation
7.
Tighten cable gland to secure against tension on
cable.
8.
Check polarity of each connection is correct to mains
connection terminals markings on appliance.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an
all-pole disconnection switch.
9.
Correctly locate appliance into its final operating
position and using a spirit level, adjust legs so that
appliance is level and at correct height.
10. Connect power supply to appliance.
11. Check electrical supply is within input rating
specification, refer to ‘Specifications’ section).
Commissioning
1.
Before leaving new installation;
a. Check following functions in accordance with operating instructions specified in ‘Operation’
section of this manual.
Light the Target Top Pilot Burner.
Light the Target Top Main Burner.
Check the Target Top Low Fire Burner operation.
Check the Target Top High Fire Burner operation.
Check the Oven Heating.
Check the Oven Thermostat operation.
Check the Oven Fan operation (GEC models only).
Check the current draw and loading for the equipment. Refer specification section for correct
electrical requirements.
C
heck that all the connections are correct and that all cover panels have been re-fitted.
Ensure that this instruction manual is left with the appliance.
Ensure that all the relevant details and contacts have been added to the front of this manual.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2.
This manual must be kept by owner for future reference, and a record of
Date of Purchase, Date
of Installation and Serial Number of Appliance recorded and kept with this manual. (These
details can be found on Rating Plate attached to front right hand corner of bottom sill.
Refer to ‘Gas Connection’ section).
NOTE:
If for some reason it is not possible to get appliance to operate correctly, turn ‘Off’
electrical power and gas supply and contact supplier of this appliance.
Make sure electrical and gas supply are turned ‘Off’ before any service or maintenance
work is carried out on appliance.
Add bridging
wires between
L1, L2 and L3.
Neutral supply
connection to N
Phase supply
connection to L1
P
N
Fig 3
Changing supply from 3 phase to single phase will increase electrical current
loading on supply cable. Ensure supply cable used is of a sufficient size for
current loading, refer to 'Electrical Supply Requirements' table.
Caution
Содержание GE570
Страница 9: ...7 Dimensions Dimensions GE570 GE576 ...
Страница 20: ...18 Wiring Schematic Static Oven Schematic GE570 ...
Страница 21: ...19 Wiring Schematic Static Oven Wiring Diagram GE570 ...
Страница 22: ...20 Wiring Schematic Convection Oven Schematic GE576 ...
Страница 23: ...21 Wiring Schematic Convection Oven Wiring Diagram GE576 ...
Страница 32: ......