background image

20 

Wiring Schematic 

Convection Oven Schematic (GE576) 

Содержание GE570

Страница 1: ...For use in GB IE 230561 14 GAS TARGET TOP RANGE ELECTRIC OVENS GE570 GE576 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L ...

Страница 2: ...800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 ...

Страница 3: ... Dimensions 7 Installation 8 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 12 Operation Guide Description of Controls Lighting the Pilot Burner Target Top Lighting the Main Burner Target Top Oven Cleaning and Maintenance 15 General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Fault Finding 17 Wiri...

Страница 4: ... MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance...

Страница 5: ...ate temperature control and infinitely variable heat with the heat radiating out from the centre of the Target Top The Main Burner is located underneath removable cast target top plates With a heavy duty high efficiency electric static or convection oven options fitted with a 900mm 6 5kW electric static oven and a 6 6kW Convection Oven created for compact modular kitchens Both ovens are fitted wit...

Страница 6: ... LP Gas Propane Target Top Target Top Input Rate N H G C 45 MJ hr 45 MJ hr Gas Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 1 0 kPa 2 60 kPa Gas Connection 3 4 B S P Male Natural Gas G20 Propane G31 Heat Input nett Nominal 11 5 kW 11 5 kW Reduced 4 7 kW 7 9 kW Gas Rate nett Nominal 1 22 m3 hr 0 89 kg hr Reduced 0 50 m3 hr 0 61 kg hr Supply Pressure 20 mbar 37 mbar Burner O...

Страница 7: ... between Nat Gas LP Gas and Butane but not Town Gas Refer to Gas Conversion and Specifications section of this manual for further details Gas Connection Gas supply connection point is located at rear of the appliance 130mm from right hand side 32mm from rear 655mm from floor and is reached from beneath appliance An optional underside connection is available Refer to the Dimensions section Connecti...

Страница 8: ...s per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type Branch supply line shall be individually overload protected to correct current rating and supply chord shall be protected against any mechanical or thermal damage A grommet is fitted around wiring entry hole into appliance All wiring connections must be tight Refer to appropriate wiring standards for size of cable that is to be s...

Страница 9: ...7 Dimensions Dimensions GE570 GE576 ...

Страница 10: ...n this section will void the warranty Components having adjustments protected e g paint sealed by manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for da...

Страница 11: ... ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON 1 It is essential that gas supply is correct for appliance to be installed and that adequate supply pressure and volume are available The following checks should be made before installation a Gas Type the appliance has been supplied for is shown on coloured stickers located above gas connection and next to rating plate Check this is...

Страница 12: ...lectrical Connection NOTE ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON Each appliance should be connected to an adequately protected power supply and isolation switch mounted adjacent to but not behind the appliance This switch must be clearly marked and readily accessible in case of fire 1 Check electricity supply is correct as shown on Rating Plate attached to lowe...

Страница 13: ...rical requirements Check that all the connections are correct and that all cover panels have been re fitted Ensure that this instruction manual is left with the appliance Ensure that all the relevant details and contacts have been added to the front of this manual b Ensure operator has been instructed in areas of correct lighting operation and shutdown procedure for appliance 2 This manual must be...

Страница 14: ...ting Indicator Lamps Amber for Top Bottom Elements Power Indicator Lamp White Target Top Gas Control Knob ๐ OFF Position PILOT Burner HIGH Flame LOW Flame Oven Top Heat Control ๐ OFF Position LOW Position 1 Position 2 Position 3 Position 4 Position HIGH Position Oven Thermostat Control ๐ OFF Position Temperature Graduations 50 C to 320 C Fig 4 This appliance is for professional use and is only to ...

Страница 15: ...be burning at full rate For a lower heat turn gas control knob fully anti clockwise to LOW position 5 Also for intermediate heat position gas control knob between HIGH and LOW positions NOTE Always set gas control knob to HIGH position when lighting main burner If pilot burner goes out during normal operation wait 5 minutes before re lighting 6 The cast iron work surface has a heat pattern that ca...

Страница 16: ... to a high setting proportionally more heat is produced at top of oven This can be used for browning etc during cooking operation With oven top heat control set on a low setting less heat is produced from top oven elements This mode is used for general baking purposes to prevent cakes etc from getting too brown and crisp on top but allow cake to cook through To obtain more top heat during cooking ...

Страница 17: ...back interior and exterior surfaces of Target Top Range with hot water a mild detergent solution and a soft scrubbing brush 2 Clean control panel with a damp cloth lightly moistened with a solution of mild detergent and water Wipe dry with a clean dry cloth 3 Brush Target Top cast iron with a soft bristled brush followed by wiping with a cloth to prevent accumulation of carbon 4 Remove drip tray a...

Страница 18: ...ub in direction of grain d Dry all components thoroughly with a dry cloth and polish with a soft dry cloth Periodic Maintenance NOTE All maintenance operations should only be carried out by a qualified service person To achieve best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service person If any sm...

Страница 19: ...On and bottles are not empty Call service provider Pilot goes out when gas control knob released Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tight...

Страница 20: ...18 Wiring Schematic Static Oven Schematic GE570 ...

Страница 21: ...19 Wiring Schematic Static Oven Wiring Diagram GE570 ...

Страница 22: ...20 Wiring Schematic Convection Oven Schematic GE576 ...

Страница 23: ...21 Wiring Schematic Convection Oven Wiring Diagram GE576 ...

Страница 24: ...emove injectors and replace with correct size injectors as shown in Gas Specifications Tables at rear of this section 3 Refit main burner to target top NOTE Ensure main burner is pulled fully towards front of unit before tightening 2 main burner securing screws 4 Set burner aeration screws X and Y for correct gas type aeration as shown in Gas Specifications Tables at rear of this section Pilot Bur...

Страница 25: ...icks Refit 2 half plate castings ensure they are correctly interlocked Refit centre casting Refit front control panel and control knob Low Fire Adjustment NOTE Adjust low fire adjustment screw on gas control valve to as shown in Gas Specifications Tables at rear of this section 1 Light main burner and check flame size on simmer LOW position NOTE Low Fire Screw should be sealed with coloured paint ...

Страница 26: ...emains correct Re adjust regulator if required 5 Screw cap nut back onto regulator Gas Type Identification Label On completion of gas conversion replace gas type identification label located at Rear of appliance above gas connection Beside the rating plate Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carr...

Страница 27: ...tor Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Injector Outer Ring Ø 2 60mm Ø 1 55mm Pilot Burner Injector 0 35 0 25 Burner Aeration Screw X Inner 25mm 25mm Burner Aeration Screw Y Outer 28mm 28mm Low Fire Adjustment 21 2 turns out ccw 1 turn out ccw Operating Pressure 1 0 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas LP Gas Propane Main Burner Injector Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Inj...

Страница 28: ...ed apart from when carrying out gas conversion if required Refer to details in this section for information Natural Gas G20 Propane G31 Main Burner Injector Inner Ring Ø 1 70mm Ø 1 10mm Main Burner Injector Outer Ring Ø 2 60mm Ø 1 55mm Pilot Burner Injector 0 35 0 25 Burner Aeration Screw X Inner 25mm 20mm Burner Aeration Screw Y Outer 28mm 25mm Low Fire Adjustment 21 2 turns out ccw 1 turn out cc...

Страница 29: ...ersion and Specifications section of this manual for further details Natural Gas Town Gas Main Burner Injector Inner Ring Ø 1 70mm Ø 4 20mm Main Burner Injector Outer Ring Ø 2 60mm Ø 6 30mm Pilot Injector 0 35 0 70 Burner Aeration Screw X Inner 25mm 20mm Burner Aeration Screw Y Outer 28mm 22mm Low Fire Adjustment 21 2 turns out ccw Blank 11 2 turns out ccw Supply Pressure 1 13 3 40 kPa 0 75 1 50 k...

Страница 30: ...jector Outer Ring Town Gas Ø 6 30mm 227985 Pilot Injector Nat 0 35 227984 Pilot Injector LPG Butane 0 25 232310 Pilot Injector Town Gas 0 70 Oven 228691 Oven Top Element 1 75kW 750 Ovens 228690 Oven Bottom Element 3 75kW 750 Ovens 228082 Oven Top Element 2kW 900 1200 Ovens 228059 Oven Bottom Element 4 5kW 900 1200 Ovens 228704 Door Spring Kit 229021 Terminal Block Mains 227392 Control Knob Thermos...

Страница 31: ...Plinth Kit Gas Regulator Gas Conversion Kits NOTE Town Gas Option is only available with specific ex factory built Town Gas models which can also be converted to any other gas Standard models can only be converted between Nat Gas LP Gas and Butane but not Town Gas Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 Town Gas 230185 BSP F F Adjustable BSP F F Convertible Model Gas ...

Страница 32: ......

Отзывы: