Blue Sea Systems P12 7531 Скачать руководство пользователя страница 3

Specifications are subject to change. See bluesea.com/P12 for current information.

1

 WARNING   

 

Refers to a potentially hazardous situation which, if not avoided, could result in death or serious injury.

The P12 Battery Charger should be installed by a qualified marine electrician. Improper installation can result in electrical shock which may cause serious 

injury or death. To reduce the risk of electrical shock, mount vertically in a dry, well ventilated location. Charge these battery types: Flooded, AGM, Gel, or 

TPPL Lead Acid batteries. Consult battery manufacturer specifications for other battery types to avoid damage. This battery charger is not intended for use 

by persons (including children) with lack of ability, experience, or knowledge, unless they have been given supervision or instruction concerning use of the 

battery charger by a person responsible for their safety. Do not recharge non-rechargeable batteries. Children should be supervised to ensure that they do 

not play with the appliance. Avoid serious injury or death from electrical shock, turn off AC supply power before opening terminations cover. 

Risk of Explosive Gases

Working in the vicinity of a Lead-Acid battery is dangerous. Batteries generate explosive gases during normal battery operation. Explosive gasses can ignite 

and may cause serious injury or death. Ensure battery location is properly ventilated according to battery manufacturer or industry standards. To reduce risk 

of battery explosion, follow these instructions and those published by the battery manufacturer. Do not smoke or cause a spark in the area around batteries 

and engines. Each time before using your charger read this manual and follow the instructions. Do not use any accessory devices that directly connect to 

the charger other than those manufactured by Blue Sea Systems and designed for use with the P12 Battery Charger. Do not operate the charger if it has 

been dropped or damaged. Contact Blue Sea Systems on how to proceed. Wear complete eye protection and protective clothing when dealing with lead 

acid batteries. Remove personal metal items such as jewelry & rings when working around batteries.

 

 CAUTION 

Refers to a potentially hazardous situation which, if not avoided, may result in injury.

Before beginning electrical installation, read the instruction manual. Disconnect all AC and DC power sources. Do not make final connections to the 
batteries until DC connections on the charger are made and verified. Do not make or break electrical connections to batteries while charging or for up to 

30 minutes after charging. Other than parts accessed under the termination cover, there are no user serviceable parts within the battery charger enclosure. 

Contact Blue Sea Systems for servicing. Charge only user selectable type batteries, other types of batteries may burst causing personal injury and damage. 

Do not use the battery charger to charge dry cell batteries that are commonly used with home appliance. These batteries may burst and cause injury to 

person and damage to property. Never charge a frozen battery.  

 

 GROUNDING PRECAUTIONS   

Marine battery chargers and inverters have two grounding connections, one from the AC system and one from the DC system. ABYC requires 

the AC grounding system to be connected to the DC grounding system through the distribution systems. Additionally, the chargers make 

connections to both systems. It is very important the systems be connected properly before the charger is installed. Otherwise the charger 

grounding system may become the sole connection between AC and DC ground and it may not be sized large enough to provide system wide 

safety function. The AC grounding conductor is the conductor with green, or green with yellow stripe included in the AC power cable and should 

be sized the same as the power and neutral conductors (see Table C page 5 for AC wire color). This will connect to the right most terminal in 

the AC connection block. There is also chassis connection terminal for a DC safety grounding wire. The DC safety ground should be green or 

marked green and sized equal to, or one wire size smaller, than the DC charge wires.

READ AND SAVE THESE INSTRUCTIONS

1. 

SAVE THESE INSTRUCTIONS

 

– This manual contains important safety and operating instructions for battery charger Models 7531 and 7532.

2.

 Do not expose charger to rain or snow.

3. 

Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire, electric shock, or injury to persons.

4. 

Do not operate charger with damaged cord – replace the cord immediately.

5. 

Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman.

6.

 Do not disassemble charger; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of 

  electric shock or fire. The battery charger must be properly assembled in accordance with the assembly instruction before it is used.

7. 

To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk.

8. 

WARNING – RISK OF EXPLOSIVE GASES.

 

a)

 WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING 

    NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS  

    EACH TIME YOU USE THE CHARGER.

  b) To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you    

    intend to use in vicinity of battery. Review cautionary marking on these products and on engine.

9. 

PERSONAL PRECAUTIONS

  a) Consider having someone close enough by to come to your aid when you work near a lead-acid battery.

  b) Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.

  c) Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery.

  d) If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at  

    least 10 minutes and get medical attention immediately.

IMPORTANT SAFETY INSTRUCTIONS

P12

 7531 AND 7532 BATTERY CHARGERS

Содержание P12 7531

Страница 1: ...perational instructions for P12 Battery Chargers This User Manual describes the product mentioned herein at the time of its publication Specifications and performance are subject to change at the disc...

Страница 2: ...roduct Dimensions and Installation Clearances 6 Included Components 7 Supplies Needed 8 Installation Instructions 9 10 Initial Charger Setup 11 Advanced Charger Setup 12 13 Reset to Manufacturer Defau...

Страница 3: ...to property Never charge a frozen battery GROUNDING PRECAUTIONS Marine battery chargers and inverters have two grounding connections one from the AC system and one from the DC system ABYC requires th...

Страница 4: ...as not to cause an arc b Be sure area around battery is well ventilated while battery is being charged c Clean battery terminals Be careful to keep corrosion from coming in contact with eyes d Add dis...

Страница 5: ...tion charging stage the batteries complete their charging by being topped off This is a less aggressive charging stage than Bulk where the current going into a particular battery bank will significant...

Страница 6: ...Charging and Alert indicators Graphic LCD Display Termination insulating cover DC output DC strain relief clamp AC strain relief and insulating cover AC input terminals under cover Mounting holes Clea...

Страница 7: ...Example 1 x Group 24 440Ah Maximum Example 4 x Group 31 Conductor Length in feet meters Charger Rating 25A 40A 6 ft 1 83 meters 14 AWG 2 5mm 8 AWG 10mm 10 ft 3 05 meters 12 AWG 4mm 8 AWG 10mm 15 ft 4...

Страница 8: ...D 7532 BATTERY CHARGERS Clearance for 12 1 4 M6 mounting hardware 7 80 198mm 11 18 284mm 7 40 188mm 8 46 215mm 4 30 109 1mm 12 94 328 8mm 14 20 TOP Recommended side clearance 1 97 50mm Recommended ove...

Страница 9: ...ded torque 5 10 in lb 0 6 1 1 Nm Pan Head Machine Screws M3 5 x 6mm Recommended torque 10 15 in lb 1 0 1 8 Nm DC Strain Relief Clamp Screws M3 x 25mm pan head machine screws Recommended torque 5 10 in...

Страница 10: ...uses or circuit breakers to verify like new condition Confirm no discoloration or corrosion exists and circuit breakers will manually trip and reset Check for proper ventilation and that no debris has...

Страница 11: ...and the battery negative common bus bar Fuses should be installed at the battery positive connections to prevent battery power from feeding back into a fault in the wiring or in the battery charger Se...

Страница 12: ...P12 Battery Charger Remote using dielectric grease Connect to the Remote Display Com port of the charger 2 Connect the Automatic Charging Relay s ACR wire to the ACR Connection port s Optional Install...

Страница 13: ...elect button 4 Once the desired battery type is highlighted press the OK button Press the Cancel button to go back Note If User mode is selected batteries will not charge until Absorb and Float voltag...

Страница 14: ...maximum amperage is the total available amperage to be supplied among all 3 outputs Selecting an amperage less than the maximum could result in under charging of batteries 5 Press the OK button once...

Страница 15: ...lected battery type The default Absorb voltages for each battery type can be seen in Table E above Warning Incorrect Absorb and Float voltages could reduce the life of your batteries Contact your batt...

Страница 16: ...Absorption Amps The maximum amount of current that a battery bank can receive while in Absorption and still change to Float If a load is active and drawing more than the designated End Absorption Amp...

Страница 17: ...rger will increase all output voltages by the value defined in Battery Tempco For example with the default Battery Tempco set to 30mv C if the temperature sensor reads 26 C then all output voltages wi...

Страница 18: ...eries are fully charged by verifying the charger is in Float mode with no active loads 2 Turn off or disconnect all DC devices that are connected to the batteries Disconnect the battery banks not bein...

Страница 19: ...You may pause Equalization at any time by pressing the pause button 17 If at any point during Equalization a DC load is applied to the battery being equalized Equalization will stop 18 You may stop Eq...

Страница 20: ...o Get Here From the Charger Summary Screen select the Menu button From other screens select the Back button Display Setup The Display Setup allows the user to customize the display settings Options Ad...

Страница 21: ...if time is being added or subtracted from the timer If paused the charger is in Float or Standby and the Absorb Timer will remain at its current time Read about Absorb Timers on page 14 Options Selec...

Страница 22: ...ee if the Fan Alert Screen appears If the Fan Alert Screen does not appear and the fan seems to be operating correctly then continue to use the battery charger normally If the Fan Alert Screen appears...

Страница 23: ...use a different AC power source or contact an electrician to diagnose the problem AC Input Voltage Too High If the input voltage rises above 265V AC the alert screen on the right will appear In this s...

Страница 24: ...present in order to share charge between battery banks However due to the P12 Battery Charger s ability to independently optimize charging for each battery bank it is favorable to isolate all battery...

Страница 25: ...or wire running from the start key switch to the starter solenoid NOTE Connecting the SI Start Isolation wire to only one of the ML ACR isolation wires will not properly integrate the P12 battery char...

Страница 26: ...he product was purchased by the first retail customer 2 The date on which the first retail customer purchases a vessel on which the product was installed Blue Sea Systems will at its sole discretion r...

Страница 27: ...oltage and Frequency measurement with alarms 2 AC ELCI Ground Fault Protection 3 AC Source Selection 4 AC Branch Circuit Protection and Switching 5 DC Battery Charger Remote Monitoring and Control 6 D...

Страница 28: ...425 Sequoia Drive Bellingham WA 98226 USA p 360 738 8230 p 800 222 7617 USA and Canada Customer Service conductor bluesea com www bluesea com 980025140 Rev 005...

Страница 29: ...ilisation des chargeurs de batterie P12 Ce manuel d utilisation d crit le produit mentionn dans ce document au moment de sa publication Les sp cifications et les performances sont sujettes modificatio...

Страница 30: ...nsions du produit et d gagements pour l installation 6 Composants inclus 7 Fournitures n cessaires 8 Instructions d installation 9 10 Configuration initiale du chargeur 11 Configuration avanc e du cha...

Страница 31: ...rels et mat riels Ne chargez jamais une batterie gel e PR CAUTION DE MISE LA MASSE Les chargeurs de batteries marines et les inverseurs ont deux raccords de mise la masse un provenant du circuit c a e...

Страница 32: ...ension pour ne pas causer un arc b S assurer que la zone autour de la batterie est bien a r e pendant la charge de la batterie c Nettoyer les bornes de la batterie Faire attention pour viter tout cont...

Страница 33: ...ion constante Dans la phase de charge d absorption les batteries effectuent leur charge en tant remplies Cette phase de charge est moins agressive que la phase Bulk charge initiale dans laquelle le co...

Страница 34: ...dicateurs de charge et d alerte Afficheur LCD graphique Couvercle isolant de connexion de sortie Sortie c c trier anti traction c c Dispositif anti traction c a et couvercle isolant Bornes d entr es c...

Страница 35: ...x groupe 24 440 Ah maximum Exemple 4 x groupe 31 Longueur de conducteur en pieds m tres Puissance du chargeur 25A 40A 6 pi 1 83 m 14 AWG 2 5 mm 8 AWG 10 mm 10 pi 3 05 m 12 AWG 4 mm 8 AWG 10 mm 15 pi...

Страница 36: ...llation P12 CHARGEURS DE BATTERIE 7531 ET 7532 D gagement pour fixations n 12 1 4 M6 7 80 198mm 11 18 284mm 7 40 188mm 8 46 215mm 4 30 109 1mm 12 94 328 8mm 14 20 Sup rieur D gagement sup rieur recomm...

Страница 37: ...10 in lb 0 6 1 1 Nm Vis m canique t te cylindrique M3 5 x 6 mm Couple recommand 10 15 in lb 1 0 1 8 Nm Vis d trier anti traction c c Vis m caniques t te cylindrique M3 x 25 mm Couple recommand 5 10 in...

Страница 38: ...er que leur tat est comme neuf V rifiez l absence de d coloration ou de corrosion et v rifiez le d clenchement et le r armement manuel des disjoncteurs V rifiez l a ration correcte et assurez vous qu...

Страница 39: ...f de la batterie et du n gatif de la batterie Les fusibles doivent tre install s au niveau des bornes positives de la batterie pour viter l alimentation de la batterie de provoquer un d faut dans le c...

Страница 40: ...batterie l arri re de la t l commande du chargeur de batterie en utilisant de la graisse di lectrique Branchez le l orifice Remote Display Com du chargeur 2 Branchez le c ble du des relais de charge a...

Страница 41: ...elect 4 Une fois le type de batterie d sir mis en vidence appuyez sur le bouton OK Appuyez sur le bouton Cancel pour revenir en arri re Note Si le mode Utilisateur est s lectionn les batteries ne se c...

Страница 42: ...tale disponible qui doit tre fournie entre les 3 sorties La s lection d une intensit inf rieure au maximum peut entra ner une charge insuffisante des batteries 5 Appuyez sur le bouton OK une fois que...

Страница 43: ...absorption par d faut pour chaque type de batterie peuvent tre v rifi es dans le Tableau E ci dessus Avertissement Des tensions d absorption et d entretien incorrectes peuvent r duire la dur e de vie...

Страница 44: ...um de courant qu un groupe de batteries peut recevoir pendant la phase d absorption en passant quand m me en phase Float Si une charge est active et absorbe plus que l intensit de fin d absorption pre...

Страница 45: ...dans Compensation de temp rature de batterie Par exemple quand la compensation de temp rature de batterie par d faut est r gl e sur 30 mv C si le capteur de temp rature rel ve 26 C toutes les tension...

Страница 46: ...n v rifiant que le chargeur est en phase Float entretien sans aucune charge active 2 D sactivez ou d branchez tous les dispositifs c c qui sont branch s aux batteries D branchez les groupes de batteri...

Страница 47: ...dure d galisation 16 Vous pouvez interrompre l galisation tout moment en appuyant sur le bouton pause 17 Si tout moment pendant l galisation une charge c c est appliqu e la batterie en cours d galisat...

Страница 48: ...rger Summary s lectionnez le bouton Menu partir d autres crans s lectionnez le bouton Back Configuration de l affichage L cran Display Setup permet l utilisateur de personnaliser les param tres d affi...

Страница 49: ...t e ou soustraite du temporisateur S il est sur pause le chargeur est en mode Float ou Standby et le temporisateur d absorption reste sa dur e actuelle Les temporisateurs d absorption sont d crits la...

Страница 50: ...alerte de ventilateur s affiche Si l cran d alerte de ventilateur ne s affiche pas et que le ventilateur semble fonctionner correctement continuez utiliser le chargeur de batterie normalement Si l cra...

Страница 51: ...entation c a diff rente ou contactez un lectricien pour diagnostiquer le probl me Tension d entr e c a trop lev e Si la tension d entr e augmente au del de 265 Vc a l cran d alerte sur la droite s aff...

Страница 52: ...dant en raison de la capacit du chargeur de batterie P12 d optimiser la charge ind pendamment pour chaque groupe de batteries il est utile d isoler tous les groupes de batteries en d sactivant la capa...

Страница 53: ...de d marreur NOTE Le branchement du fil SI isolement au d marrage un seul des c bles d isolement ML ACR ne permet pas l int gration correcte du chargeur de batterie P12 avec le ML ACR 3 Branchez un c...

Страница 54: ...gnifie 1 La date laquelle le produit a t achet par le premier client au d tail 2 La date laquelle le premier client au d tail ach te un bateau sur lequel le produit a t install Blue Sea Systems sa seu...

Страница 55: ...nsit c a de tension et de fr quence avec alarmes 2 Protection de d faut la masse c a ELCI 3 S lection de source c a 4 Protection et commutation de circuit c c 5 Contr le et commande distance de charge...

Страница 56: ...425 Sequoia Drive Bellingham WA 98226 USA T l 360 738 8230 T l 800 222 7617 Service client tats Unis et Canada conductor bluesea com www bluesea com 980025140 R v 005...