SECTION 7
HYDRAULIC SYSTEM SERVICING
7-1. LINES AND FITTINGS
WARNING:
When the platform is raised, pressure
exists in the hydraulic system lines and
fittings. To ensure release of pressure,
platform must be fully lowered and the
batteries disconnected before
performing any maintenance on the
hydraulic system.
NOTE:
Leaking hydraulic fittings may be remedied by
simply tightening fittings. If this does not
remedy the leak, the fittings or line must be
replaced.
1.
Fully lower the platform.
2.
Engage the emergency power disconnect switch
and turn off key switch.
3.
Remove the compartment cover as described in
paragraph
WARNING:
Relieve pressure off the system prior to
opening any lines.
CAUTION:
Hydraulic oil can damage parts. Wipe off
any oil immediately. Provide a container
under the line or fitting before
disconnecting.
4.
Refer to
and remove leaking line or
fitting and replace it with a new line or fitting.
5.
Check level of hydraulic oil. If required, add
hydraulic oil to bring to proper level. Use hydraulic
.
6.
Disengage the emergency power disconnect
switch and turn on key switch.
7.
Operate the lift and lower buttons to refill the
cylinder and lines with hydraulic oil.
8.
Check level of hydraulic oil. If required, add
hydraulic oil to bring to proper level. Use hydraulic
.
9.
Install the compartment cover as described in
paragraph
7-2.
HYDRAULIC PUMP, MOTOR, AND RESER-
VOIR ASSY
The hydraulic pump/motor assembly can be
disassembled and repaired. However, a defective
pump,
valve or motor requires replacement of that
compo-nent.
WARNING:
When the platform is raised, pressure
exists in the hydraulic system lines and
fittings. To ensure release of pressure,
platform must be fully lowered and the
batteries disconnected before
performing any maintenance on the
hydraulic system.
7-2.1. Removal
1.
Fully lower the platform.
2.
Engage the emergency power disconnect switch
and turn off key switch.
3.
Remove the compartment cover as described in
paragraph
4.
Tag and disconnect electrical leads from motor
and solenoid of pump/motor assembly.
NOTE:
The reservoir and tube will be filled with
hydraulic oil. Place a container under the
pump assembly to catch any hydraulic oil.
5.
Disconnect hose from pump/motor assembly.
6.
While supporting pump/motor assembly, remove
two screws and two lock washers.
7.
Remove the pump/motor assembly.
8.
Remove the bracket from the pump/motor
assembly.
9.
Install pump/motor assembly in reverse order of
removal.
21
Содержание BG E-Step
Страница 3: ...NOTES 3...
Страница 14: ...NOTES 14...
Страница 16: ...NOTES 16...
Страница 18: ...NOTES 18...
Страница 20: ...Figure 6 1 Frame ED_0001 20...
Страница 22: ...Figure 7 1 Hydraulic System ED_0004 22...
Страница 24: ...NOTES 24...
Страница 28: ...NOTES 28...
Страница 29: ...SECTION 9 OPTIONAL EQUIPMENT 9 1 N A 29...
Страница 30: ...NOTES 30...
Страница 32: ...Figure 10 1 Frame ED_0001 32...
Страница 34: ...Figure 10 2 Operator Platform ED_0002 34...
Страница 36: ...Figure 10 3 Operating Control Assembly ED_0003 36...
Страница 38: ...Figure 10 4 Decals 38 EC_0009...
Страница 40: ...Figure 10 5 Hydraulic System ED_0004 40...
Страница 42: ...Figure 10 6 Hydraulic Pump Assembly ED_0005 42...
Страница 44: ...Figure 10 7 Lift Cylinder ED_0006 44...
Страница 46: ...Figure 10 8 Electrical System ED_0007 46...
Страница 48: ...Figure 10 9 Wiring Harness ED_0008 48...