4) TROUBLESHOOTING - CASE HISTORY
TROUBLE
PROBABLE CAUSE
SOLUTION
The machine does not start
The switch is not set to ON
The cables are not connected
Repeat the switching on steps
Check the connections
The machine does not start
The battery poles are inverted
Replace the fuse in
the box of the power supply
cable
Connect the battery properly
The machine stops at the
minimum effort
The battery is discharged
Recharge the battery
5) MAINTENANCE
Before any cleaning/maintenance action the operator has to absolutely disconnect the electric cables.
Maintenance has to be made by skilled personnel only, with the sole use of original spare parts.
In order to assure a high performance for a long time operator has to make a simple maintenance work as
mentioned in the following table.
POS.
COMPONENT
ACTION
FREQUENCY
1
Carbon rods
Check if assembled
correctly
Daily
2
Power supply cables
and connectors
Check if undamaged
Daily
3
TIRRENO
Cleaning after use
Daily
4
Piston
Grease through the
proper opening
2/3 times a day
NOTE: Do not use air compressors
NOTE: Use molybdenum disulfide lubricant
Replacement of carbon rods
Carbon rods can be easily replaced when damaged or worn. Follow the steps below:
a) disconnect the electric cable
b) unscrew the nut
c) take off the rod
d) plug in the new rod
e) fasten again the screw again with the nut
NOTE: The inside mechanisms of TIRRENO are protected for a lifetime with a special grease. DO