QRI-0910 Thermostatic Mixing Valve
1.
Let water flow for at least two minutes to allow supply temperature to stabilize.
2.
Calibrate the mixed water outlet temperature by placing a thermometer in the mixed water stream.
3.
To adjust the setting of the valve, loosen locking cap screw with hex wrench (refer to Figure 3)
Cap must be lifted 1/4” to adjust temperature. To increase the temperature, turn counterclockwise.
To decrease temperature turn clockwise.
4.
Lower handle and tighten screw.
5.
Check outlet temperature.