background image

2021-11

1 866 907 0122     blubathworks.com

 

 8

QRI-0001

Содержание INOX QRI-0030

Страница 1: ...INOX wall mount shower rough in valve kit Installation Guide 2021 11 1 866 907 0122 blubathworks com QRI 0001 Pages 4 8 QRI 0030 QRI 0910 Pages 9 15 QRI 0103 x2 Page 16...

Страница 2: ...Details Minimum Pressure 15 PSI Maximum Pressure 145 PSI Recommended Pressure 29 72 PSI Maximum Water Temperature 80 C 176 F Maximum Recommended Water Temperature 65 C 149 F the temperature Installat...

Страница 3: ...r mix or combine cleaning agents Abrasive cleaners and unsuitable scouring agents such as scouring pads Installation Notes Important Install this product according to the installation guide Our produc...

Страница 4: ...water inlet mixed hot water inlet hot water from water tank 1 2 3 3 Component Diagram for QRI 0030 rough in valve kit 1 QRI 0001 single handle hydroprogressive wall rough in valve 2 QRI 0910 thermosta...

Страница 5: ...2021 11 1 866 907 0122 blubathworks com 4 Attention Min Max depth in wall QRI 0001 rough in valve...

Страница 6: ...2021 11 1 866 907 0122 blubathworks com 5 Attention Placement in wall QRI 0001 rough in valve...

Страница 7: ...2021 11 1 866 907 0122 blubathworks com 6 Position Application on plasterboard or counterframe Finish the coating close to the edge of the plastic protective cover QRI 0001 rough in valve...

Страница 8: ...2021 11 1 866 907 0122 blubathworks com 7 Installation wall mount single handle with spout configuration VALVE 02 MODO STERO SERIES Universal Position QRI 0001 rough in valve...

Страница 9: ...2021 11 1 866 907 0122 blubathworks com 8 QRI 0001...

Страница 10: ...Tampering with limit stop in any way may result in scalding temperature causing serious bodily harm and or death Warning Need for Periodic Inspection and Yearly Maintenance Periodic inspection and ye...

Страница 11: ...nuts are placed over tailpieces prior to soldering threading to pipe or using w press 6 For valves with Quick Connect tailpieces refer to Quick Connect Installation instructions page 13 NOTICE To prev...

Страница 12: ...2021 11 1 866 907 0122 blubathworks com 11 QRI 0910 Thermostatic Mixing Valve...

Страница 13: ...he mixed water outlet temperature by placing a thermometer in the mixed water stream 3 To adjust the setting of the valve loosen locking cap screw with hex wrench refer to Figure 3 Cap must be lifted...

Страница 14: ...2021 11 1 866 907 0122 blubathworks com 13 QRI 0910 Thermostatic Mixing Valve QUICK CONNECT INSTALLATION...

Страница 15: ...2021 11 1 866 907 0122 blubathworks com 14 QRI 0910 Thermostatic Mixing Valve...

Страница 16: ...2021 11 1 866 907 0122 blubathworks com 15 QRI 0910...

Страница 17: ...1 1 866 907 0122 blubathworks com 16 QRI 0103 Shut Off Valve 1 Body 2 Retainer 3 Ball 4 Check valve insert 5 Stem 6 Gland nut 7 Lever and grip 8 Lever nut 9 O ring 10 Seat 2 12 Stem packing 13 Stem be...

Страница 18: ...roprogressive wall rough in valve 2 QRI 0910 thermostatic mixing valve 3 QRI 0103 x 2 qty shut offs with integral check valve cold water in outlet one outlet two cold water inlet mixed hot water inlet...

Страница 19: ...andle hydroprogressive wall rough in valve 2 QRI 0910 thermostatic mixing valve 3 QRI 0103 x 2 qty shut offs with integral check valve mixed hot water inlet cold water inlet cold water in hot water fr...

Страница 20: ...roprogressive wall rough in valve 2 QRI 0910 thermostatic mixing valve 3 QRI 0103 x 2 qty shut offs with integral check valve cold water in hot water from water tank cold water inlet mixed hot water i...

Страница 21: ...effective Limestone if cream cleanser is not enough treat scale with a 25 solution of vinegar and mild hot water and give it some time to dissolve Then clean with if possible deionised mild water and...

Отзывы: